scholarly journals Level of Total Volatile Organic Compounds (TVOC) in the context of Indoor Air Quality (IAQ) in Office Buildings

Author(s):  
Michal Kraus ◽  
Ingrid Juhásová Šenitková
2021 ◽  
Vol 11 (9) ◽  
pp. 4056
Author(s):  
Sami Lestinen ◽  
Simo Kilpeläinen ◽  
Risto Kosonen ◽  
Maria Valkonen ◽  
Juha Jokisalo ◽  
...  

Night ventilation methods have been used in educational buildings to guarantee indoor air quality at the beginning of occupied periods. A typical method has been to pre-start ventilation 2 h before the space usage. Another selection has been to ventilate a building continuously during the night with a minimum airflow rate that can dilute material emissions. In this study, the pre-started, continuous, and intermittent ventilation methods were compared by assessing indoor air quality in field measurements. The daytime ventilation was operating normally. The test periods lasted for 2 weeks. Indoor air quality was assessed by measuring the total volatile organic compounds and microbial concentrations using the quantitative polymerase chain reaction method. Additionally, the thermal conditions, carbon dioxide, and pressure differences over the building envelope were measured. The results show that the night ventilation strategy had negligible effects on microbial concentrations. In most cases, the indoor air microbial concentrations were only a few percent of those found outdoors. The averaged concentration of total volatile organic compounds was at the same level with all the night ventilation methods at the beginning of the occupied periods in the mornings. The concentrations reached a minimum level after 2-h ventilation. The concentrations of total volatile organic compounds were higher during the day than at night. This reveals that space usage had the largest effect on the total volatile organic compounds. Generally, the results show that continuous night ventilation does not significantly affect the biological and chemical contaminants. Consequently, a 2-h flushing period is long enough to freshen indoor air before occupancy.


Indoor Air ◽  
1997 ◽  
Vol 7 (4) ◽  
pp. 225-240 ◽  
Author(s):  
L. Molhave ◽  
G. Clausen ◽  
B. Berglund ◽  
J. Ceaurriz ◽  
A. Kettrup ◽  
...  

Atmosphere ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 286
Author(s):  
Dorina Camelia Ilieș ◽  
Florin Marcu ◽  
Tudor Caciora ◽  
Liliana Indrie ◽  
Alexandru Ilieș ◽  
...  

Poor air quality inside museums is one of the main causes influencing the state of conservation of exhibits. Even if they are mostly placed in a controlled environment because of their construction materials, the exhibits can be very vulnerable to the influence of the internal microclimate. As a consequence, museum exhibits must be protected from potential negative effects. In order to prevent and stop the process of damage of the exhibits, monitoring the main parameters of the microclimate (especially temperature, humidity, and brightness) and keeping them in strict values is extremely important. The present study refers to the investigations and analysis of air quality inside a museum, located in a heritage building, from Romania. The paper focuses on monitoring and analysing temperature of air and walls, relative humidity (RH), CO2, brightness and particulate matters (PM), formaldehyde (HCHO), and total volatile organic compounds (TVOC). The monitoring was carried out in the Summer–Autumn 2020 Campaign, in two different exhibition areas (first floor and basement) and the main warehouse where the exhibits are kept and restored. The analyses aimed both at highlighting the hazard induced by the poor air quality inside the museum that the exhibits face. The results show that this environment is potentially harmful to both exposed items and people. Therefore, the number of days in which the ideal conditions in terms of temperature and RH are met are quite few, the concentration of suspended particles, formaldehyde, and total volatile organic compounds often exceed the limit allowed by the international standards in force. The results represent the basis for the development and implementation of strategies for long-term conservation of exhibits and to ensure a clean environment for employees, restorers, and visitors.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 22357-22365 ◽  
Author(s):  
Faan Hei Hung ◽  
Kim-Fung Tsang ◽  
Chung Kit Wu ◽  
Yucheng Liu ◽  
Hao Wang ◽  
...  

2018 ◽  
Vol 21 (1) ◽  
pp. 41-49
Author(s):  
Takahiro ISHIZAKA ◽  
Ayato KAWASHIMA ◽  
Naoki HISHIDA ◽  
Noriaki HAMADA

Sign in / Sign up

Export Citation Format

Share Document