Alternative Site Blood Glucose Testing: A Multicenter Study

2003 ◽  
Vol 5 (6) ◽  
pp. 983-989 ◽  
Author(s):  
D. Fedele ◽  
A. Corsi ◽  
C. Noacco ◽  
F. Prisco ◽  
S. Squatrito ◽  
...  
2017 ◽  
Vol 43 (5) ◽  
pp. 490-491 ◽  
Author(s):  
V. Dubourdieu ◽  
H. Mosbah ◽  
C. Amouyal ◽  
A. Hartemann ◽  
F. Andreelli

2009 ◽  
Vol 403 (1-2) ◽  
pp. 167-172 ◽  
Author(s):  
Chien-Hua Wei ◽  
Ting-Chun Peng ◽  
Peng-Yuan Wang ◽  
Jui-Jane Lin ◽  
Mei-Lin Chuang ◽  
...  

Diabetes Care ◽  
2003 ◽  
Vol 26 (4) ◽  
pp. 981-985 ◽  
Author(s):  
D. M. Bina ◽  
R. L. Anderson ◽  
M. L. Johnson ◽  
R. M. Bergenstal ◽  
D. M. Kendall

2000 ◽  
Vol 2 (2) ◽  
pp. 221-229 ◽  
Author(s):  
Ben Feldman ◽  
Geoff McGarraugh ◽  
Adam Heller ◽  
Nancy Bohannon ◽  
Jay Skyler ◽  
...  

2021 ◽  
pp. 1-9
Author(s):  
Haifen Zhang ◽  
Shuhui Lailan ◽  
Shiyu Zhao ◽  
Qian Liu ◽  
Nina Fang ◽  
...  

BACKGROUND: Portable blood glucose meters are the main method for detecting the blood glucose status of clinical patients. OBJECTIVE: To investigate the accuracy of detecting blood glucose in haemodialysis patients by sampling two blood glucose meters through the haemodialysis line. METHODS: Convenient sampling was used to select 80 patients with maintenance haemodialysis. The patients were sampled through the arterial end of the haemodialysis line within three minutes of being put on the machine. One specimen was tested by glycemeter1, which can identify the type of blood in the arteries and veins, and glycemeter2, which can only detect blood glucose in the capillaries for bedside blood glucose testing. The other specimen was sent to the laboratory biochemical analyser for blood glucose testing. RESULTS: When the blood glucose value of the first blood glucose meter (No. 1) was compared with the laboratory biochemical analyser, the correlation coefficient was r = 0.805 (p < 0.05), the out of value of the first blood glucose meter accounted for 4.4%, and the consistency reached 95% (p < 0.05). When the blood glucose value of the second blood glucose meter (No. 2) was compared with the laboratory biochemical analyser, the correlation coefficient was r = 0.800 (p < 0.05), the out of value of the second blood glucose meter accounted for 4.4%, and the consistency reached 95% (p < 0.05). CONCLUSIONS: For patients with maintenance haemodialysis, the blood glucose values detected by the two bedside blood glucose meters using arteriovenous mixed blood in the pipeline do not affect the accuracy and can respond more realistically.