Liquid-chromatographic determination of aminoglutethimide in plasma.

1983 ◽  
Vol 29 (6) ◽  
pp. 1104-1105 ◽  
Author(s):  
B A Robinson ◽  
F N Cornell

Abstract A simple, rapid "high-performance" liquid-chromatographic procedure is presented for the determination of aminoglutethimide in plasma. After precipitation of the protein with acetonitrile, an aliquot of the supernate is injected directly onto a radially compressed, reversed-phase column. The aminoglutethimide is isocratically eluted with a mobile phase of acetonitrile/water/tert-butyl ammonium phosphate. The method is both accurate and precise and has been in routine use in our laboratory for more than 12 months.

1983 ◽  
Vol 29 (10) ◽  
pp. 1840-1842 ◽  
Author(s):  
J Lehmann ◽  
H L Martin

Abstract We have adapted to erythrocytes a method for the determination of alpha- and gamma-tocopherols in plasma and platelets. Erythrocytes (50 microL) were extracted with methanol containing tocol (internal standard) and pyrogallol. Tocopherols were partitioned into chloroform, washed, and injected in methanol onto a reversed-phase (C18) "high-performance" liquid-chromatographic column. The mobile phase was methanol/water (99/1 by vol) at a flow rate of 2 mL/min and detection was with a "high-performance" spectrophotofluorometer. The limit of detection for either tocopherol is 0.10 microgram/mL of packed cells. Analytical recoveries ranged from 93 to 104%. Some values for tocopherols in human erythrocytes are presented.


1984 ◽  
Vol 30 (7) ◽  
pp. 1228-1230 ◽  
Author(s):  
A K Dhar ◽  
H Kutt

Abstract This method for determination of haloperidol in plasma is based on "high-performance" isocratic liquid chromatography with the use of a C8 bonded reversed-phase column at room temperature. Haloperidol and the internal standard (chloro-substituted analog) are extracted from alkalinized plasma into isoamyl alcohol/heptane (1.5/98.5 by vol) and back-extracted into dilute H2SO4. The aqueous phase is directly injected onto the column. The mobile phase is a 30/45/25 (by vol) mixture of phosphate buffer (16.5 mmol/L, pH 7.0), acetonitrile, and methanol. Unlike other liquid-chromatographic procedures for haloperidol, commonly used psychotropic drugs do not interfere. Analysis can be completed within an hour. The procedure is extremely sensitive (1.0 microgram/L) and is well reproducible (CV 5.6% for a 2.5 micrograms/L concentration in plasma).


1982 ◽  
Vol 65 (3) ◽  
pp. 753-756
Author(s):  
Walter F Schmidt

Abstract A high performance liquid chromatographic procedure has been developed for the assay of phenprocoumon in tablets. In comparison to the present official USP assay procedure, it is equivalent in precision and accuracy and is faster and more specific. A mobile phase consisting of a 1% solution of acetic acid in acetonitrile-water (4 + 3) separates phenprocoumon from warfarin internal standard on a 6 μm octadecylsilane (ODS) column with UV detection at 311 nm. The method enables the concurrent determination of phenprocoumon and possible contaminants such as salicylic acid.


1982 ◽  
Vol 65 (5) ◽  
pp. 1063-1065
Author(s):  
Stanley E Roberts

Abstract A high performance liquid chromatographic (HPLC) method is described for the quantitative determination of primidone in tablets. A ground tablet sample is diluted directly in the mobile phase, at a concentration of about 1 mg/mL of primidone, mixed and deaerated, and filtered. The resulting solution is then quantitated by HPLC. The average spike recoveries for the 50 mg and 250 mg tablets were 101.2% and 99.0%, respectively. The average recovery for an authentic mixture formulated at the 250 mg level was 100.1% with a relative standard deviation of 0.45%.


2001 ◽  
Vol 24 (15) ◽  
pp. 2315-2324 ◽  
Author(s):  
Rolando González-Hernández ◽  
Lauro Nuevas-Paz ◽  
Laritza Soto-Mulet ◽  
Miguel López-López ◽  
Joseph Hoogmartens

Sign in / Sign up

Export Citation Format

Share Document