scholarly journals Retrospective 1-year outcome follow-up in 200 patients supported with HeartMate 3 and HeartWare left ventricular assist devices in a single centre

2020 ◽  
Vol 57 (6) ◽  
pp. 1160-1165 ◽  
Author(s):  
Marcus Mueller ◽  
Christoph Hoermandinger ◽  
Gregor Richter ◽  
Johanna Mulzer ◽  
Dmytro Tsyganenko ◽  
...  

Abstract OBJECTIVES Various trials have assessed the outcome and reliability of the HeartWare HVAD (HW) and HeartMate 3 (HM3) left ventricular assist devices. A direct comparison of clinical outcomes and of the complication profile of these 2 left ventricular assist devices is lacking. We present a retrospective analysis of patients supported with HM3 and HW as a left ventricular assist device. METHODS Preoperative data, complications and outcomes including a 1-year follow-up of patients supported with the HM3 and HW in a single centre were retrospectively analysed. Both pumps were implanted on- or off-pump, employing standard and minimally invasive techniques. For logistic reasons, the 2 device types were implanted in an alternating manner, thereby reducing the systematic bias for pump selection. We considered this to be an appropriate approach, as no differences in respect of survival or the complication profile of the two device types have been demonstrated. Anticoagulation was similar in patients with both pumps according to our anticoagulation protocol, with a target international normalized ratio of 2.5–3.0, a home monitoring system and blood pressure management with a mean arterial target pressure of 70–80 mmHg. RESULTS Between October 2015 and April 2017, 100 patients underwent implantation of the HW and 100 patients underwent implantation of the HM3. The median time on the device was 0.98 years (range 0–2.23 years). The median age was 58.5 (51–65) versus 57 (49–64) years (P = 0.456); the number of male patients was 87 versus 88 (P = 0.831). Of the HW patients, 73% were rated as having an INTERMACS level I or II, compared to 57% of the HM3 patients (P = 0.018). There were no further differences in preoperative data. A total of 14 patients had pre-, intra- or post-pump blood flow obstruction in the HW group versus 4 in the HM3 group [hazard ratio (HR) 2.5 (0.7–8.8), P = 0.103]. There were no differences regarding gastrointestinal bleeding [HR 1.25 (0.56–2.64), P = 0.624] or driveline infection (0.68 vs 0.8 events per patient-year, P = 0.0789). The incidence of ischaemic stroke was similar in both groups [HR 0.72 (0.25–2.09), P = 0.550]. Cerebral bleeding was more frequent in patients supported with HW [HR 6.79 (1.43–32.20), P = 0.016]. The incidence of cerebrovascular accidents, on the other hand, was similar in both groups [HR 1.85 (0.83–4.19), P = 0.13]. The incidence of haemocompatibility-related adverse events, however, was significantly higher in the HW group (113 points corresponding to 1.28 events per patient-year versus 69 points corresponding to 0.7 events per patient-year, P < 0.001). The 1-year survival was similar in both groups [62.2%, 95% confidence interval (CI) (0.53–0.73) vs 66.7%, 95% CI (0.58–0.767), P = 0.372]. CONCLUSIONS Our data show that the complication profile differs between the 2 pumps, but that early survival is comparable.

2019 ◽  
Vol 56 (6) ◽  
pp. 1054-1061
Author(s):  
Osnat Itzhaki Ben Zadok ◽  
Ben Ben-Avraham ◽  
Aviv Shaul ◽  
Yoav Hammer ◽  
Victor Rubachevski ◽  
...  

Abstract OBJECTIVES In this study, we aimed to determine the comparative outcomes of patients supported with continuous-flow left ventricular assist devices (LVADs): HeartMate 2 (HM2), HeartWare (HW) and HeartMate 3 (HM3) in a real-world setting. METHODS The study was an investigator-initiated comparative retrospective analysis of patients who underwent continuous-flow LVAD implantation at our institution between 2008 and 2017. The follow-up duration was 18 months after implantation. RESULTS The study included 105 continuous-flow LVAD-supported patients of whom 51% (n = 54), 24% (25) and 25% (26) underwent implantation of HM2, HW and HM3, respectively. During follow-up, patients who were supported with HM3 versus either HM2 or HW LVADs demonstrated a lower risk of stroke (0% vs 26%, P < 0.001 and 0% vs 40%, P < 0.001, respectively) and lower rates of thrombosis (0% vs 31%, P < 0.001 and 0% vs 12%, P < 0.001, respectively), findings that were consistent with their calculated haemocompatibility scores (cumulative score 5, 89 and 56 for HM3, HM2 and HW, respectively, P < 0.001). Moreover, patients supported with HM3 versus HW had fewer unplanned hospitalizations [median 1 (25th–75th interquartile range 0–2) vs 3 (interquartile range 2–4), P = 0.012]. Importantly, survival free from stroke or device exchange was higher in patients supported with HM3 compared with either the HM2 or the HW LVADs [hazard ratio (HR) 2.77, confidence interval (CI) 1.13–6.78; P = 0.026 and HR 2.70, CI 1.01–7.20; P = 0.047, respectively]. CONCLUSIONS HM3 device currently presents better prognostic and adverse events profiles when compared with the HM2 or the HW LVADs. A larger-scale head-to-head comparison between the devices is warranted in order to confirm our findings.


2018 ◽  
Vol 10 (S15) ◽  
pp. S1703-S1710 ◽  
Author(s):  
Leonhard Wert ◽  
Jasmin S. Hanke ◽  
Günes Dogan ◽  
Marcel Ricklefs ◽  
Felix Fleißner ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document