scholarly journals Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection†

2019 ◽  
Vol 56 (3) ◽  
pp. 572-578 ◽  
Author(s):  
Tim Berger ◽  
Gabriel Weiss ◽  
Andreas Voetsch ◽  
Zsuzsanna Arnold ◽  
Maximilian Kreibich ◽  
...  

Abstract OBJECTIVES The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex™ hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection. METHODS All consecutive patients [n = 88; median age 59 (49–67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex™ device was implanted in 55 patients and the E-vita Open graft in 33 patients. RESULTS Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex™ hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses. CONCLUSIONS In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.

Author(s):  
Yosuke Inoue ◽  
Hitoshi Matsuda ◽  
Jiro Matsuo ◽  
Takayuki Shijo ◽  
Atsushi Omura ◽  
...  

Abstract OBJECTIVES Resection of a primary entry tear is essential for the treatment of Stanford type A acute aortic dissection (AAAD). In DeBakey type III retrograde AAAD (DBIII-RAAAD), resection of the primary entry tear in the descending aorta is sometimes difficult. The frozen elephant trunk technique and thoracic endovascular aortic repair (TEVAR) enable the closure of the primary entry in the descending aorta. The aim of this study was to investigate the efficacy of resection or closure of primary entry, i.e. entry exclusion, in patients with DeBakey type III retrograde-AAAD. METHODS The medical records of 654 patients with AAAD who underwent emergency surgery between January 2000 and March 2019 were retrospectively reviewed, and 80 eligible patients with DeBakey type III retrograde-AAAD were divided into the excluded (n = 50; age, 62 ± 12 years) and residual (n = 30; age, 66 ± 14 years) groups according to postoperative computed tomography angiographic data of the false lumen around the primary entry. The excluded group was defined as having a postoperative false lumen at the level of the elephant trunk or thrombosis of the endograft including primary entry. Patients with early false lumen enhancement around the elephant trunk or an unresected primary entry tear after isolated hemiarch replacement were included in the residual group. The early and long-term surgical outcomes were compared between the groups. RESULTS The in-hospital mortality rate was 8% (6/80), with no significant difference observed between the excluded and the residual groups (10% and 7%, respectively; P > 0.99). Ninety-five percentage of the patients (20/21) achieved entry exclusion with stent grafts including the frozen elephant trunk procedure and TEVAR. Spinal cord ischaemia was not observed in either group. The cumulative overall survival at 5 years was comparable between the 2 groups (76% and 81% in the excluded and residual groups, respectively; P = 0.93). The 5-year freedom from distal aortic reoperation rate was significantly higher in the excluded group (97%) than in the residual group (97% vs 66%; P = 0.008). CONCLUSIONS Not only resection but also closure using the entry exclusion approach for DeBakey type III retrograde-AAAD utilizing new technologies including the frozen elephant trunk technique and TEVAR might mitigate dissection-related reoperations.


2018 ◽  
Vol 26 (6) ◽  
pp. 972-976 ◽  
Author(s):  
Boris N Kozlov ◽  
Dmitri S Panfilov ◽  
Igor V Ponomarenko ◽  
Andrey G Miroshnichenko ◽  
Aleksandra A Nenakhova ◽  
...  

Author(s):  
Daichi Takagi ◽  
Takuya Wada ◽  
Wataru Igarashi ◽  
Takayuki Kadohama ◽  
kentaro kiryu ◽  
...  

We describe a case of frozen elephant trunk deployment unintentionally malpositioned into the false lumen. An 83-year-old man underwent total arch repair with a frozen elephant trunk for type A acute aortic dissection complicated by mesenteric malperfusion. However, intraoperative transesophageal echocardiography showed expansion of the false lumen in the descending aorta, suggesting a malpositioned frozen elephant trunk into the false lumen. Endovascular fenestration of the dissecting flap and subsequent endograft deployment from the inside of the malpositioned frozen elephant trunk graft to the true lumen of the descending aorta was successfully performed under intravascular ultrasound guidance.


2016 ◽  
Vol 64 (S 01) ◽  
Author(s):  
D.-S. Dohle ◽  
K. Tsagakis ◽  
T. Schlosser ◽  
Z. Haidari ◽  
J. Benedik ◽  
...  

Author(s):  
Koichi Tamai ◽  
Daijiro Hori ◽  
Koichi Yuri ◽  
Atsushi Yamaguchi

Abstract Using a frozen elephant trunk (FET) in patients with acute aortic dissection is an effective method to induce aortic remodelling after surgery. A 40-year-old man with Stanford type A acute aortic dissection underwent emergency total arch replacement with FET. The FET was inserted into the descending aorta under direct vision. However, transoesophageal echocardiography after the deployment of the FET revealed that it was misdeployed in the false lumen. An additional FET was deployed in the true lumen to redirect the blood flow to the true lumen. The patient was discharged from the hospital without any major complications. Computed tomography 6 months after surgery revealed enhanced aortic remodelling without any signs of stent graft-induced new entry. Additional deployment of a FET into the true lumen could be an option for a misdeployed FET in the false lumen.


2019 ◽  
Vol 29 (5) ◽  
pp. 753-760 ◽  
Author(s):  
Akira Furutachi ◽  
Masanori Takamatsu ◽  
Eijiro Nogami ◽  
Kohei Hamada ◽  
Junji Yunoki ◽  
...  

Abstract OBJECTIVES The aim of this study was to evaluate the outcomes of the frozen elephant trunk (FET) technique, using the J Graft FROZENIX for Stanford type A acute aortic dissection, in comparison with the unfrozen elephant trunk technique. METHODS Between January 2010 and August 2018, we performed total arch replacement for Stanford type A acute aortic dissection in our hospital. Thirty patients were treated by the elephant trunk procedure (ET group), and 20 patients were treated by the FET procedure (FET group). To evaluate aortic remodelling, we measured the area of the aorta, the true lumen and the false lumen at 12 months of follow-up. RESULTS Preoperative characteristics and operation time were not significantly different between the 2 groups. The quantity of blood transfused was much greater in the ET group than in the FET group. Resection or closure of the most proximal entry tear was obtained in 73.3% (22 out of 30 patients) in the ET group and 100% (20 out of 20 patients) in the FET group (P = 0.015). There was no case that had recurrent nerve palsy or paraplegia in the FET group. Stent graft-induced new entry occurred in 3 cases (15.8%) in the FET group. There were no significant differences between the 2 groups in aortic area, true lumen area or false lumen area. CONCLUSIONS Total arch replacement with the FET technique in Stanford type A acute aortic dissection carries a risk of distinct complications; however, with thorough advance planning, it should be possible to safely institute this treatment. Further randomization, with a comparison of each technique, is required to provide clear conclusions whether the FET is useful for acute Stanford type A aortic dissection.


Author(s):  
Markus Liebrich ◽  
Efstratios I Charitos ◽  
Sebastian Schlereth ◽  
Helfried Meißner ◽  
Tobias Trabold ◽  
...  

Abstract OBJECTIVES The goal of this study was to investigate the association between the localization of the distal anastomosis (zone 2/3), the stent graft length (100–160 mm), the position of the distal end of the hybrid prosthesis and the need for secondary aortic intervention (SAI) in acute and chronic thoracic aortic disease after the frozen elephant trunk procedure. METHODS From 2009 through 2020, a total of 232 patients (137 men; mean age, 61.7 ± 13.8 years) were treated with the frozen elephant trunk procedure. The main indications were acute aortic dissection type A (n = 106, 46%), chronic aortic dissection type A (n = 52, 22%) and degenerative thoracic aortic aneurysm (n = 74, 32%). RESULTS The rate of SAI was significantly higher when we performed a distal anastomosis in zone 2 rather than in zone 3, whereas the rate of SAI was less frequent if the distal positioning of the hybrid prosthesis was below TH 4–5. Combining the zone 2 concept and the short stent graft length (100 mm) was associated with a significantly higher rate of SAIs. Patients with a distal anastomosis in zone 2 were significantly less likely to have a recurrent laryngeal nerve injury (P < 0.001). However, no association between a specific arch zone of a distal anastomosis and the occurrence of spinal cord injury was observed. CONCLUSIONS Rates of SAIs are highest in patients who were treated with a distal anastomosis in zone 2 and a short stent graft (100 mm) with the distal end of the hybrid prosthesis at vertebral level TH 2–3.


Sign in / Sign up

Export Citation Format

Share Document