scholarly journals Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography

2008 ◽  
Vol 29 (20) ◽  
pp. 2526-2535 ◽  
Author(s):  
K. K. Poh ◽  
R. A. Levine ◽  
J. Solis ◽  
L. Shen ◽  
M. Flaherty ◽  
...  
2008 ◽  
Vol 61 (5) ◽  
pp. 494-500 ◽  
Author(s):  
Leopoldo Pérez de Isla ◽  
José Zamorano ◽  
Rocío Pérez de la Yglesia ◽  
Sara Cioccarelli ◽  
Carlos Almería ◽  
...  

1995 ◽  
Vol 25 (3) ◽  
pp. 635
Author(s):  
Hyeon-Cheol Gwon ◽  
Ju-Hee Zo ◽  
Hyo-Soo Kim ◽  
Dae-Won Sohn ◽  
Byung-Hee Oh ◽  
...  

2019 ◽  
Vol 6 (4) ◽  
pp. 97-103 ◽  
Author(s):  
Andaleeb A Ahmed ◽  
Robina Matyal ◽  
Feroze Mahmood ◽  
Ruby Feng ◽  
Graham B Berry ◽  
...  

Objective Due to its circular shape, the area of the proximal left ventricular tract (PLVOT) adjacent to aortic valve can be derived from a single linear diameter. This is also the location of flow acceleration (FA) during systole, and pulse wave Doppler (PWD) sample volume in the PLVOT can lead to overestimation of velocity (V1) and the aortic valve area (AVA). Therefore, it is recommended to derive V1 from a region of laminar flow in the elliptical shaped distal LVOT (away from the annulus). Besides being inconsistent with the assumptions of continuity equation (CE), spatial difference in the location of flow and area measurement can result in inaccurate AVA calculation. We evaluated the impact of FA in the PLVOT on the accuracy of AVA by continuity equation (CE) in patients with aortic stenosis (AS). Methods CE-based AVA calculations were performed in patients with AS once with PWD-derived velocity time integral (VTI) in the distal LVOT (VTILVOT) and then in the PLVOT to obtain a FA velocity profile (FA-VTILVOT) for each patient. A paired sample t-test (P < 0.05) was conducted to compare the impact of FA-VTILVOT and VTILVOT on the calculation of AVA. Result There were 46 patients in the study. There was a 30.3% increase in the peak FA-VTILVOT as compared to the peak VTILVOT and AVA obtained by FA-VTILVOT was 29.1% higher than obtained by VTILVOT. Conclusion Accuracy of AVA can be significantly impacted by FA in the PLVOT. LVOT area should be measured with 3D imaging in the distal LVOT.


2014 ◽  
Vol 97 (4) ◽  
pp. 1255-1258 ◽  
Author(s):  
Arminder S. Jassar ◽  
Melissa M. Levack ◽  
Ricardo D. Solorzano ◽  
Alison M. Pouch ◽  
Giovanni Ferrari ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document