scholarly journals 778 Acute clinical valve thrombosis after transcatheter mitral valve-in-valve replacement

2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Emiliano Calvi ◽  
Nicola Bernardi ◽  
Antonino Milidoni ◽  
Giuliana Cimino ◽  
Angelica Cersosimo ◽  
...  

Abstract Aims Transcatheter heart valve (THV) thrombosis is a frequent and potentially life-threatening complication of transcatheter mitral valve replacement (TMVR), occurring in approximately 12% of patients (mainly within the first 3 months after the procedure). The majority of THV thromboses is non-obstructive and subclinical, and remains undetected until a routine echocardiogram is performed. Methods A 65 years old male was suffering from post-ischaemic dilated cardiomyopathy and severe left ventricle systolic dysfunction (LVEF 28%), secondary to a previous STEMI in 2010 treated with primary PCI on proximal LAD; after the STEMI he developed a left ventricle aneurysm and a subsequent severe secondary mitral regurgitation. In late 2020 he underwent a surgical valve replacement with a biologic valve (Perimount Magna Mitral Ease n. 27), alongside a left ventricle reshaping (Dor procedure). After a few months, the patient developed worsening dyspnoea and severe exercise intolerance; a transesophageal echocardiogram (TEE) showed an extensive valve degeneration with diffuse leaflet thickening determining severe valve stenosis and regurgitation. The patient was then admitted to the Cardiology department. A coronary angiography was performed, showing good result of previous PCI and excluding other critical stenoses. The patient then underwent a transcatheter valve-in-valve replacement with a Sapien S3 n. 29 in mitral position. The patient was already in chronic therapy with acetilsalicilic acid (ASA), and after the procedure anticoagulant therapy with Warfarin was started. In the post-procedural period the patient developed an acute worsening of the LVEF with severe hypotension, likely due to after-load mismatch; hence, supportive inotropic therapy with Adrenalin and Enoximone was required. A TEE performed 7 days after the procedure showed absence of diastolic excursion of posterior and lateral cusps and leaflet thickening with a 4 mm thrombotic apposition on the ventricular side, determining severe valve stenosis with markedly increased transvalvular gradients (peak gradient 20 mmHg, mean gradient 11 mmHg). A CT scan of the heart confirmed the valve thrombosis on the inferior and lateral leaflets. Results Unfractioned heparin (UFH) was then added to ASA and Warfarin (INR target of 3.0). After 11 days of aggressive antithrombotic therapy a new TEE was performed, showing marked reduction in transvalvular gradients (peak gradient 10 mmHg, mean gradient 5 mmHg) due to partial dissolution of the thrombotic formation. Warfarin was then stopped, and after switching from UFH to Enoxaparin the patient was discharged asymptomatic and in good general conditions, with indication of follow-up with TEE at 1 month. Conclusions Valve-in-valve TMVR is a relatively new and still infrequent procedure, therefore few evidences about its complications are currently available. Thrombosis on these valves is not rare (12%), but usually develops on the atrial side of the leaflets; interestingly, in this patient the thrombosis was on the ventricular side, likely due to an acute reduction in flow velocity caused by the after-load mismatch and the subsequent cardiogenic shock.

Author(s):  
Hemant Chaturvedi ◽  
Ravinder Rao

The incidence of prosthetic valve thrombosis post transcatheter mitral valve replacement remains largely unknown. Although it may occur more frequently than after transcatheter aortic valve replacement, only isolated cases have been reported up to now. This unique large mushroom thrombus post TMVR case is first of its kind reported ever. 3D transesophageal as well as transthoracic echocardiography play very important role in early diagnosis and for treatment decision


Author(s):  
Nicola Maschietto ◽  
Ashwin Prakash ◽  
Pedro del Nido ◽  
Diego Porras

Background: Despite the improvement of surgical techniques for mitral valve (MV) repair in children, mitral valve replacement (MVR) is sometimes still necessary. MVR and redo-MVR continue to be burdened by early postoperative mortality and long-term morbidity with only about 75% of these patients being alive or transplant-free 10 years after the initial MVR. Although transcatheter MVR (TMVR) is a well-established intervention in high surgical risk adults, only a few pediatric valve-in-valve case reports have been published. The purpose of this study was to describe our initial experience with the off-label use of the Sapien S3 valve for TMVR in a highly selected pediatric patient population. Methods: We conducted a retrospective analysis of pediatric patients who underwent TMVR at Boston Children’s Hospital between October 2018 and July 2020. Results: Eight consecutive high surgical risk pediatric patients (median age, 9 years; range, 8–15) underwent TMVR (7 as valve-in-valve, 1 in a native MV). Each patient previously underwent multiple MV surgeries or MVR (median 4, range 2–5) and was highly symptomatic (Ross functional class 3 or 4). The indication for TMVR was mitral stenosis in 4 patients, regurgitation in 1, and mixed disease in 3. TMVR was successful in each patient, effectively reduced the left atrium and pulmonary hypertension ( P =0.012 and 0.043 respectively), and was carried out without significant complications. Conclusions: TMVR is an attractive alternative to MVR in high surgical risk patients. In this small series, TMVR was acutely effective and safe, with very encouraging early results.


Prosthesis ◽  
2020 ◽  
Vol 2 (1) ◽  
pp. 39-45
Author(s):  
Salvatore Pasta ◽  
Caterina Gandolfo

Obstruction of the left ventricular outflow tract (LVOT) is a common complication of transcatheter mitral valve replacement (TMVR). This procedure can determine an elongation of an LVOT (namely, the neo-LVOT), ultimately portending hemodynamic impairment and patient death. This study aimed to understand the biomechanical implications of LVOT obstruction in a patient who underwent TMVR using a transcatheter heart valve (THV) to repair a failed bioprosthetic heart valve. We first reconstructed the heart anatomy and the bioprosthetic heart valve to virtually implant a computer-aided-design (CAD) model of THV and evaluate the neo-LVOT area. A numerical simulation of THV deployment was then developed to assess the anchorage of the THV to the bioprosthetic heart valve as well as the resulting Von Mises stress at the mitral annulus and the contract pressure among implanted bioprostheses. Quantification of neo-LVOT and THV deployment may facilitate more accurate predictions of the LVOT obstruction in TMVR and help clinicians in the optimal choice of the THV size.


2016 ◽  
Vol 68 (16) ◽  
pp. 1814-1815 ◽  
Author(s):  
Giuliana Capretti ◽  
Marina Urena ◽  
Dominique Himbert ◽  
Eric Brochet ◽  
Coppelia Goublaire ◽  
...  

2021 ◽  
Author(s):  
Lina Ya’qoub ◽  
Marvin Eng

We will review transcatheter mitral valve replacement (TMVR) and discuss this evolving cutting edge procedure in terms of types (valve in valve, valve in ring and valve in mitral annular calcification MAC), clinical indications, pre-procedural planning and value of pre-procedural imaging including computed tomography role, technical challenges encountered in these procedures, potential complications for each type of TMVR, and potential strategies to mitigate and avoid such complications, We will review the currently available devices dedicated for mitral valve replacement, with a summary of their preliminary data and early outcome results. We will also discuss knowledge gaps and ideas for future research.


Sign in / Sign up

Export Citation Format

Share Document