scholarly journals 96-08: Short-term amiodarone treatment for atrial fibrillation after catheter ablation induces a transient thyroid dysfunction: Results from the placebo-controlled randomized AMIO-CAT trial

EP Europace ◽  
2016 ◽  
Vol 18 (suppl_1) ◽  
pp. i61-i61 ◽  
Author(s):  
Søren Zöga Diederichsen ◽  
Stine Darkner ◽  
Xu Chen ◽  
Arne Johannessen ◽  
Steen Pehrson ◽  
...  
EP Europace ◽  
2019 ◽  
Vol 21 (7) ◽  
pp. 1055-1062 ◽  
Author(s):  
Søren Zöga Diederichsen ◽  
Stine Darkner ◽  
Xu Chen ◽  
Arne Johannessen ◽  
Steen Pehrson ◽  
...  

Aims Prolonged corrected QT interval (QTc) might be associated with arrhythmia recurrence after atrial fibrillation (AF) ablation. The effect of short-term amiodarone in this setting remains unknown. This study seeks to quantify short-term amiodarone’s impact on QTc, and to investigate QTc and amiodarone treatment as predictors of recurrence of arrhythmia after ablation. Methods and results The Short-term AMIOdarone treatment after CATheter ablation for atrial fibrillation (AMIO-CAT) trial randomized patients to 8 weeks of oral amiodarone or placebo following AF ablation. Scheduled and symptom-driven 12-lead electrocardiography and 3-day Holter-monitorings were performed. The endpoint was atrial fibrillation, atrial flutter or atrial tachycardia (AF/AT) lasting >30 s. The cut-off for prolonged QTc was 450 ms for men and 460 ms for women. A total of 212 patients were included, of which 108 were randomized to amiodarone and 104 to placebo. From baseline to 1 month QTc in the amiodarone group increased by 27 (±30) ms, while at 6 months QTc had normalized. After 3-months of blanking, new AF/AT recurrence was detected in 63% of patients with prolonged QTc vs. 41% of patients with normal QTc at baseline, and in multivariate Cox regression, prolonged QTc was associated with AF/AT recurrence [hazard ratio (HR) 2.19, P = 0.023]. Among patients with baseline QTc below median, amiodarone treatment decreased the rate of AF/AT recurrences (HR 0.43, P = 0.008). Conclusions Amiodarone increased QTc with 27 ms compared to placebo, and this effect decreased rapidly after drug discontinuation. Prolonged QTc at baseline independently predicted AF/AT recurrence, and baseline QTc identified patients who would possibly benefit from short-term amiodarone following ablation.


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Luigi Di Biase ◽  
Rodney Horton ◽  
Chintan Trivedi ◽  
Prasant Mohanty ◽  
Sanghamitra Mohanty ◽  
...  

Introduction: Radiofrequency catheter ablation of atrial fibrillation is performed under fluoroscopic guidance and therefore carries radiation risk exposure for the both the patient and the operator. Three-dimensional mapping systems and newer technologies to allow non-fluoroscopic catheter visualization together with intracardiac echo have reduced but not abolished the fluoroscopy exposure. We aim to demonstrate the feasibility, the safety and the efficacy of catheter ablation for atrial fibrillation without the use of fluoroscopy. Methods: A totally fluoro-less approach was developed for AF ablation at our Institution. 94 consecutive AF patients underwent zero fluoroscopy catheter ablation for atrial fibrillation. In the zero fluoroscopy cases, the fluoroscopy arm was kept far away from the patient table. Access including double trans-septal, mapping with the Carto 3 system and ablation were all performed without fluoroscopy with the use of ICE and the Carto 3 system. These 94 patients were compared with 94 control patients matched for age, sex and type of AF who underwent AF ablation by the same operator with the use of fluoroscopy. Results: Baseline characteristics were similar between fluoroless (N=94, Age=64.5 ± 10.1, 75.5% male, 48% paroxysmal) and control (N=94, Age=65.1 ± 9.9, 72.3% male, 50% paroxysmal) group. Non-PV triggers were detected and ablated in 51 (54.3%) and 56 (59.6%) patients in fluoroless and control group respectively (p=0.5). Average fluoro time in control group was 10.1 ± 4.7 minutes. Procedure duration was comparable (120.4 ± 25.8 vs. 122.2 ± 28.7, p =0.6). After the short term median follow-up of 4.5 (4 – 6.5) months, 10 (10.6 %) patients in flourless and 9 (9.6%) patients in control group experienced recurrences (p=0.8).One pericardial effusion requiring pericardiocenteis occurred in the fluoroless group. Conclusions: Our series show that zero fluoroscopy ablation of atrial fibrillation with the use of newer technologies is feasible, safe and efficacious at the short term follow up. Importantly in our series the double transeptal was performed without fluoroscopy and the ablation was not limited to the pulmonary veins only but included ablation of the posterior wall, the coronary sinus and the left atrial appendage.


2015 ◽  
Vol 38 (10) ◽  
pp. 1142-1150 ◽  
Author(s):  
VINCENT GABUS ◽  
ANNE ROLLIN ◽  
PHILIPPE MAURY ◽  
ANDREI FORCLAZ ◽  
PATRIZIO PASCALE ◽  
...  

Medicina ◽  
2020 ◽  
Vol 56 (9) ◽  
pp. 465
Author(s):  
Masako Baba ◽  
Kentaro Yoshida ◽  
Yoshihisa Naruse ◽  
Ai Hattori ◽  
Yoshiaki Yui ◽  
...  

Background and objectives: Pulmonary vein (PV) reconnection is a major reason for recurrence after catheter ablation of paroxysmal atrial fibrillation (PAF). However, the timing of the recurrence varies between patients, and recurrence >1 year after ablation is not uncommon. We sought to elucidate the characteristics of atrial fibrillation (AF) that recurred in different follow-up periods. Materials and Methods: Study subjects comprised 151 consecutive patients undergoing initial catheter ablation of PAF. Left atrial volume index (LAVi) and atrial/brain natriuretic peptide (ANP/BNP) levels were systematically measured annually over 3 years until AF recurred. Results: Study subjects were classified into four groups: non-recurrence group (n = 84), and short-term- (within 1 year) (n = 30), mid-term- (1–3 years) (n = 26), and long-term-recurrence group (>3 years) (n = 11). The short-term-recurrence group was characterized by a higher prevalence of diabetes mellitus (hazard ratio 2.639 (95% confidence interval, 1.174–5.932), p = 0.019 by the Cox method), frequent AF episodes (≥1/week) before ablation (4.038 (1.545–10.557), p = 0.004), and higher BNP level at baseline (per 10 pg/mL) (1.054 (1.029–1.081), p < 0.0001). The mid-term-recurrence group was associated with higher BNP level (1.163 (1.070–1.265), p = 0.0004), larger LAVi (mL/m2) (1.033 (1.007–1.060), p = 0.013), and longer AF cycle length at baseline (per 10 ms) (1.194 (1.058–1.348), p = 0.004). In the long-term-recurrence group, the ANP and BNP levels were low throughout follow-up, as with those in the non-recurrence group, and AF cycle length was shorter (0.694 (0.522–0.924), p = 0.012) than those in the other recurrence groups. Conclusions: Distinct characteristics of AF were found according to the time to first recurrence after PAF ablation. The presence of secondary factors beyond PV reconnections could be considered as mechanisms for the recurrence of PAF in each follow-up period.


Sign in / Sign up

Export Citation Format

Share Document