scholarly journals Transseptal puncture and catheter ablation via the superior vena cava approach for persistent atrial fibrillation in a patient with polysplenia syndrome and interruption of the inferior vena cava: contact force–guided pulmonary vein isolation

EP Europace ◽  
2016 ◽  
pp. euw095
Author(s):  
Hiroshi Kato ◽  
Shoichi Kubota ◽  
Takuya Goto ◽  
Koichi Inoue ◽  
Naohiko Oku ◽  
...  
2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Masatoshi Narikawa ◽  
Masayoshi Kiyokuni ◽  
Junya Hosoda ◽  
Toshiyuki Ishikawa

Abstract Background Transseptal puncture and pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) are generally performed via the inferior vena cava (IVC). However, in cases where the IVC is inaccessible, a specific strategy may be needed. Case summary An 86-year-old woman with paroxysmal AF and an IVC filter in situ was referred to our hospital for ablation therapy. An IVC filter for pulmonary embolism and deep venous thrombosis had been implanted 15 years prior, therefore we selected a transoesophageal echocardiography (TOE)-guided transseptal puncture using a superior vena cava (SVC) approach. After the single transseptal puncture, we performed fast anatomical mapping, voltage mapping by multipolar mapping catheter, and then PVI by contact force-guided radiofrequency catheter using a steerable sheath. Following the ablation, bidirectional conduction block between the four pulmonary veins and the left atrium was confirmed by both radiofrequency and mapping catheter. No complications occurred and no recurrence of AF was documented in the 12 months after the procedure. Discussion When performing a transseptal puncture during AF ablation, an SVC approach, via access through the right internal jugular vein, enables the sheath to directly approach the left atrium without angulation and improves operability of the ablation catheter. Combining the use of general anaesthesia, TOE, a steerable sheath, and contact force-guided ablation may contribute to achieving minimally invasive PVI with a single transseptal puncture via an SVC approach.


Author(s):  
Hee-jin Kwon ◽  
Dong Seop Jeong ◽  
Hye Ree Kim ◽  
Seung-Jung Park ◽  
Kyoung-Min Park ◽  
...  

Introduction: In patients with non-paroxysmal AF, various ablation strategies have been attempted to target non-pulmonary vein (PV) foci or to achieve substrate modification beyond pulmonary vein isolation (PVI). The efficacy of empirical ablation of the SVC, one of the most common non-PV foci, is unclear. The aim of this study was to investigate the efficacy and safety of additional superior vena cava (SVC) isolation in patients with non-paroxysmal atrial fibrillation (AF) undergoing thoracoscopic surgical ablation. Methods and Results: A total of 191 patients with persistent or longstanding persistent AF was enrolled. All patients underwent total thoracoscopic surgical ablation for AF, and half of them also received empirical SVC isolation. We compared the atrial-tachyarrhythmia (ATa)-free survival rate and procedure-related complications in the two groups of patients. The 3-year ATa-free survival rate was 53% in the SVC-isolation group and 52% in the no-SVC-isolation group, (p = 0.644). There were no differences between the two groups with respect to AF type or LA size. Procedure-related complications occurred in 12 patients (6%). Pacemakers were implanted only in 3 patients from the SVC-isolation group. The only factor influencing recurrence of ATa was LA diameter. Conclusions: Empirical SVC isolation during thoracoscopic ablation for persistent AF did not improve patient outcomes.


EP Europace ◽  
2017 ◽  
Vol 19 (10) ◽  
pp. 1670-1675 ◽  
Author(s):  
Kai Xu ◽  
Yuanlong Wang ◽  
Shaohui Wu ◽  
Li Zhou ◽  
Liang Zhao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document