Abstract A reverse-phase liquid chromatographic method is described for the assay of medroxyprogesterone acetate in tablets. An octadecylsilane (C18) column with a mobile phase of methanol-O.OlM dibasic ammonium phosphate (80 + 20 v/v, pH 7.2 ± 0.1) and photometric detection at 254 nm separates medroxyprogesterone acetate from excipients. Detector responses were linear to concentrations of medroxyprogesterone acetate over the range 50-150 μg/mL (r = 0.999). Mean recovery of medroxyprogesterone acetate added to tablet excipients was 100.8%. Mean assay results were 101.3% (n = 3). The assay results are comparable to those obtained by the compendial liquid chromatographic method

1984 ◽  
Vol 67 (6) ◽  
pp. 1118-1120
Author(s):  
Ting Susan ◽  
◽  
R L Brown ◽  
L A Dougherty ◽  
J B Schepman ◽  
...  

Abstract A reverse phase liquid chromatographic method for the determination of methyldopa, methyldopa-hydrochlorothiazide, and methyldopachlorothiazide in tablets was collaboratively studied by 8 laboratories. Each collaborator received 20 samples that included drug substance, synthetic and commercial tablet compositions. The overall repeatability and reproducibility standard deviations for commercial tablets were 1.11 and 1.75% for methyldopa, 0.96 and 1.62% for chlorothiazide, and 1.21 and 2.15% for hydrochlorothiazide, respectively. The overall recoveries of methyldopa, chlorothiazide, and hydrochlorothiazide added to synthetic tablets were 100.78, 100.70, and 101.34%, respectively. The method has been adopted official first action.


1992 ◽  
Vol 75 (1) ◽  
pp. 62-65 ◽  
Author(s):  
R Khazanchi ◽  
S Walia ◽  
S K Handa

Abstract A reversed-phase liquid chromatographic method has been developed for the determination of fenamiphos and the metabolites fenamiphos sulfoxide, fenamiphos sulfone, 3-methyl-4-(methylthlo)- phenol, and 3-methyl-4-(methylsulflnyl)phenol. Trace quantities of the nematlclde and Its metabolites In soil can be determined simultaneously. The limit of detection of the method was 5 ppm. Recoveries of fenamiphos and Its degradation products at fortification levels of 25,50, and 100 ppm ranged from 99.2 to 100.8%. Standard deviations ranged from 0.29 to 0.70 ppm.


1985 ◽  
Vol 68 (3) ◽  
pp. 545-546
Author(s):  
Michael Tsougros

Abstract A stability indicating liquid chromatographic method for the determination of diazepam in tablets was collaboratively studied by 6 laboratories. The method uses a Cig reverse phase column, a methanolwater mobile phase, p-tolualdehyde as the internal standard, and photometric detection at 254 nm. The collaborators were supplied with a synthetic tablet powder and 3 commercial tablet samples. The mean recovery of diazepam from the synthetic tablet powder was 100.2%. For all samples analyzed, the coefficient of variation was < 1.5%. The method has been adopted official first action.


1989 ◽  
Vol 72 (2) ◽  
pp. 231-234 ◽  
Author(s):  
Mercedes Jalón ◽  
Majesús Peńa ◽  
Julián C Rivas

Abstract A reverse-phase liquid chromatographic method is described for the determination of carminic acid in yogurt. A C18 column is used with acetonitrile-1.19M formic acid (19 + 81) as mobile phase and diode array detection. Sample preparation includes deproteinization with papain and purification in a polyamide column. The relative standard deviation for repeated determinations of carminic acid in a commercial strawberry-flavored yogurt was 3.0%. Recoveries of carminic acid added to a natural-flavored yogurt ranged from 87.2 to 95.3% with a mean of 90.2%. The method permits measurement of amounts as low as 0.10 mg/kg.


1983 ◽  
Vol 66 (4) ◽  
pp. 909-912 ◽  
Author(s):  
Steven P Swanson ◽  
Venkatachalam Ramaswamy ◽  
Val R Beasley ◽  
William B Buck ◽  
Harold H Burmeister

Abstract The gas-liquid chromatographic method for the determination of T-2 toxin in plasma is described. The toxin is extracted with benzene, washed with aqueous sodium hydroxide, and chromatographed on a small Florisil column; the heptafluorobutyryl derivative is prepared by reaction with heptafluorobutyrylimidazole. The T-2 HFB derivative is chromatographed onOV-1 at 230°C and measured with an electron capture detector. Iso-T-2, an isomer of T-2 toxin, is added to samples as an internal standard before extraction. Recoveries averaged 98.0 ± 5.5% at levels ranging from 50 to 1000 ng/m L. The limit of detection is 25 ng/mL.


1995 ◽  
Vol 78 (2) ◽  
pp. 307-309 ◽  
Author(s):  
Theresa A Gehring ◽  
Willie M Cooper ◽  
Claude L Holder ◽  
Harold C Thompson

Abstract A liquid chromatographic method was developed for determination of the essential nutrient thiamine (vitamin Bi) in rodent feed. Thiamine was extracted with hydrochloric acid, separated by reversed-phase liquid chromatography, derivatized postcolumn to thiochrome with potassium hydroxide and potassium ferricyanide, and detected by fluorescence. Excitation and emission wavelengths were 370 and 430 nm, respectively. Detector response was linear in the range of 2.58 to 15.5 ng of thiamine injected. Instrument detection limit was 5 pg of thiamine injected.


1984 ◽  
Vol 67 (2) ◽  
pp. 225-227 ◽  
Author(s):  
Richard L Everett ◽  
◽  
L Allgire ◽  
R J Ballbach ◽  
J Booth ◽  
...  

Abstract A reverse phase liquid chromatographic method was developed for determining methocarbamol in injection and tablet dosage forms. The injections require dilution only; the tablets require a nitration step before introduction into the chromatograph. Response for methocarbamol was linear over the range 0-18 μg, using an ultraviolet detector at 274 nm. Recoveries by the author ranged from 96.1 to 101.9% for authentic injection formulations and 98.0 to 101.0% for authentic tablet formulations. A collaborative study of the method by 6 laboratories resulted in standard deviations of 1.70 and 2.22 for injection and tablet dosage forms, respectively. The method has been adopted official first action.


1987 ◽  
Vol 70 (5) ◽  
pp. 834-836
Author(s):  
Ella S Moore

Abstract A liquid chromatographic method for the determination of coumarin anticoagulants in tablets was collaboratively studied by 7 laboratories. The method uses an octadecylsilane-bonded microparticulate column, tetrahydrofuran-methanol-water-acetic acid mobile phase, and photometric detection at 311 nm. Each collaborator received samples of warfarin sodium, phenprocoumon, and dicumarol as a synthetic composite and as commercial individual and composited tablets. Pooled average assay values for synthetic and commercial tablet samples of warfarin sodium were 101.6 and 99.5%, respectively, with a combined reproducibility SD of 2.38% (CV = 2.37%) and combined repeatability SD of 1.49% (CV = 1.49%). Pooled average (SD) assay values for dicumarol and phenprocoumon commercial samples were 98.0 (2.27) and 101.3% (4.00), respectively. The content uniformity determinations of 2 mg warfarin sodium and 25 mg dicumarol tablets indicated average tablet contents (range) of 99.5% (91.0-116.0) and 98.0% (89.8-108.8), respectively. The method has been approved interim official first action


1997 ◽  
Vol 80 (3) ◽  
pp. 549-554 ◽  
Author(s):  
Karl-Erik Hellenás ◽  
Carina Branzell ◽  
H Poutanen ◽  
T Suortti ◽  
R Kaario ◽  
...  

Abstract Twelve laboratories participated in a collaborative study to evaluate precision parameters of a liquid chromatographic method for analysis of the glycoalkaloids α-solanine and α-chaconine in potato tubers. Samples consisted of frozen potato tuber homogenates distributed as 3 blind duplicates and 3 split-level pairs. The analytical method included aqueous extraction, workup on disposable solidphase extraction cartridges, and reversed-phase chromatography with photometric detection at 202 nm. Results for α-solanine and α-chaconine were received from 10 and 9 laboratories, respectively. Relative standard deviations for reproducibilo ity for α-solanine and α-chaconine were similar, ranging from 8 to 13% in the applied concentration range of 12 to 260 mg/kg fresh weight.


1984 ◽  
Vol 67 (3) ◽  
pp. 497-499
Author(s):  
Stephen C Slahck ◽  
◽  
J B Audino ◽  
O O Bennett ◽  
B D Folsom ◽  
...  

Abstract A liquid chromatographic method for the determination of propoxur in technical and formulated products has been subjected to a collaborative study with 8 participating collaborators. Formulations are extracted with acetonitrile and analyzed by reverse phase chromatography, with n-butyrophenone as an internal standard. Collaborators were furnished with samples of technical, 70% wettable powder, 1.5 emulsifiable, and 2% bait. Coefficient of variation values obtained on the 4 samples were 0.34, 0.68, 3.25, and 5.41%, respectively. The method has been adopted official first action.