scholarly journals Development of a Stability-Indicating High-Performance Liquid Chromatographic Method for the Simultaneous Determination of Alprazolam and Sertraline in Combined Dosage Forms

2008 ◽  
Vol 91 (6) ◽  
pp. 1344-1353 ◽  
Author(s):  
Ashutosh Pathak ◽  
Sadhana J Rajput

Abstract The objective of the current study was to develop a validated stability-indicating high-performance liquid chromatographic method for alprazolam and sertraline in combined dosage forms. The method was validated by subjecting the drugs to forced decomposition under hydrolysis, oxidation, photolysis, and thermal stress conditions prescribed by the International Conference on Harmonization. The drugs were successfully separated from major and minor degradation products on a reversed-phase C18 column by using 75 mM potassium dihydrogen phosphate buffer (pH 4.3)acetonitrilemethanol (50 45 5, v/v/v) as the mobile phase with determination at 227 nm. The flow rate was 0.9 mL/min. The method was validated with respect to linearity, precision, accuracy, system suitability, and robustness. The responses were linear over the ranges of 180 and 5200 g/mL for alprazolam and sertraline, respectively. The recoveries of both drugs from a mixture of degradation products were in the range of 97101. The utility of the procedure was verified by its application to marketed formulations that were subjected to accelerated stability studies. The method distinctly separated the drugs and degradation products, even in actual samples. The products formed in marketed tablets were similar to those formed during stress studies.

1998 ◽  
Vol 81 (5) ◽  
pp. 999-1004 ◽  
Author(s):  
Célestin Munimbazi ◽  
Lloyd B Bullerman

Abstract A high-performance liquid chromatographic method using UV absorption was developed for determining moniliformin in corn. The toxin was extracted with water containing 1 % tetrabutylammonium hydrogen sulfate (w/v). Paired moniliformin was partitioned into dichloromethane, which was evaporated to dryness at 50 C. The residue was dissolved in water and applied to a disposable stronganion exchange solid-phase extraction tube. Adsorbed moniliformin was eluted from the tube with 0.05M sodium dihydrogen phosphate monohydrate (pH 5). It was determined by ion-pair reversed-phase chromatography and UV measurement at 229 nm. The minimum detectable amount of pure moniliformin was 0.25 ng/injection (signal-to-noise ratio = 3:1). The detector response was linear from 0.25 to at least 20 ng. The limit of determination was 0.025 μg/g corn. Recoveries of moniliformin from corn spiked at 0.025,0.05,0.25, and 1.0 μg/g averaged 96.5,96.2, 97.2, and 97.8% respectively


Author(s):  
Shivani Kalokhe ◽  
Santaji Nalwade ◽  
Pallavi Patil ◽  
Poonam Raskar

Abstract A novel, delicate, stability-indicating, gradient, reversed-phase high-performance liquid chromatographic method has been established for the quantitative estimation of methocarbamol (MTC) and its impurities present in a pharmaceutical oral suspension. XBridge C18, 5 μm, 250 mm × 4.6 mm column was used to accomplish chromatographic separation with a buffered mobile phase consisting of a mixture of 0.01 M of sodium dihydrogen phosphate (pH 7.0 buffer) and methanol in the ratio of 95:05 (v/v), respectively, were used as solvent A and a mixture of methanol and Milli-Q water in the ratio 90:10 (v/v), respectively, was used as solvent B. Analysis was carried out at 0.8 mL/min flow rate and the detection wavelength at 225 nm. The compartment temperature of the column is put at 25°C. The resolution of MTC and its four impurities has been attained >2.0 for all pairs of compounds. Significant degradation of MTC was photolytic, thermal and oxidative stress conditions. Validation of the developed method was performed as stated by the International Conference on Harmonization guidelines with regard to all validation parameters like specificity, accuracy, linearity, precision, limit of detection, limit of quantitation and robustness.


Sign in / Sign up

Export Citation Format

Share Document