Neurophysiology of Cochlear Implant Users II: Comparison Among Speech Perception, Dynamic Range, and Physiological Measures

2002 ◽  
Vol 23 (6) ◽  
pp. 516-531 ◽  
Author(s):  
Jill B. Firszt ◽  
Ron D. Chambers ◽  
Nina Kraus
2014 ◽  
Vol 20 (1) ◽  
pp. 1-16 ◽  
Author(s):  
Feddo B. van der Beek ◽  
Jeroen J. Briaire ◽  
Johan H.M. Frijns

Objectives: This study analyzed the predictability of fitting levels for cochlear implant recipients based on a review of the clinical levels of the recipients. Design: Data containing threshold levels (T-levels) and maximum comfort levels (M-levels) for 151 adult subjects using a CII/HiRes 90K cochlear implant with a HiFocus 1/1 J electrode were used. The 10th, 25th, 50th, 75th and 90th percentiles of the T- and M-levels are reported. Speech perception of the subjects, using a HiRes speech coding strategy, was measured during routine clinical follow-up. Results: T-levels for most subjects were between 20 and 35% of their M-levels and were rarely (<1/50) below 10% of the M-levels. Furthermore, both T- and M-levels showed an increase over the first year of follow-up. Interestingly, levels expressed in linear charge units showed a clear increase in dynamic range (DR) over 1 year (29.8 CU; SD 73.0), whereas the DR expressed in decibels remained stable. T-level and DR were the only fitting parameters for which a significant correlation with speech perception (r = 0.34, p < 0.01, and r = 0.33, p < 0.01, respectively) could be demonstrated. Additionally, analysis showed that T- and M-level profiles expressed in decibels were independent of the subjects' across-site mean levels. Using mixed linear models, predictive models were obtained for the T- and M-levels of all separate electrode contacts. Conclusions: On the basis of the data set from 151 subjects, clinically applicable predictive models for T- and M-levels have been obtained. Based on one psychophysical measurement and a population-based T- or M-level profile, individual recipients' T- and M-levels can be approximated with a closed-set formula. Additionally, the analyzed fitting level data can serve as a reference for future patients. i 2014 S. Karger AG, Basel


2012 ◽  
Vol 23 (05) ◽  
pp. 341-349 ◽  
Author(s):  
Elizabeth J. Robinson ◽  
Lisa S. Davidson ◽  
Rosalie M. Uchanski ◽  
Christine M. Brenner ◽  
Ann E. Geers

Background: For pediatric cochlear implant (CI) users, CI processor technology, map characteristics, and fitting strategies are known to have a substantial impact on speech perception scores at young ages. It is unknown whether these benefits continue over time as these children reach adolescence. Purpose: To document changes in CI technology, map characteristics, and speech perception scores in children between elementary grades and high school, and to describe relations between map characteristics and speech perception scores over time. Research Design: A longitudinal design with participants 8–9-yr-old at session 1 and 15–18-yr-old at session 2. Study Sample: Participants were 82 adolescents with unilateral CIs, who are a subset of a larger longitudinal study. Mean age at implantation was 3.4 yr (range: 1.7–5.4), and mean duration of device use was 5.5 yr (range: 3.8–7.5) at session 1 and 13.3 yr (range: 10.9–15) at session 2. Data Collection and Analysis: Speech perception tests at sessions 1 and 2 were the Lexical Neighborhood Test (LNT) presented at 70 dB SPL (LNT-70) and Bamford-Kowal-Bench sentences in quiet (BKB-Q) presented at 70 dB SPL. At session 2, the LNT was also administered at 50 dB SPL (LNT-50), and BKB sentences were administered in noise with a +10 dB SNR (BKB-N). CI processor technology type and CI map characteristics (coding strategy, number of electrodes, threshold levels, and comfort levels) were obtained at both sessions. Electrical dynamic range was computed, and descriptive statistics, correlations, and repeated-measures ANOVAs were employed. Results: Participants achieved significantly higher LNT and BKB scores, at 70 dB SPL, at ages 15–18 than at ages 8–9 yr. Forty-two participants had 1–3 electrodes either activated or deactivated in their map between test sessions, and 40 had no change in number of active electrodes (mean change: −0.5; range: −3 to +2). After conversion from arbitrary clinical map units to charge-per-phase in nanocoulombs (nC), no significant difference was found for T levels across time. Average comfort levels (C levels) decreased by 19 nC. Seventy-three participants (89%) upgraded their CI processor technology type. At both sessions, significant correlations were found between electrical dynamic range (EDR) and all speech perception measures except LNT-50 (r range: .31 to .47; p < 0.01). Similarly, significant correlations were also found between C levels and all speech perception measures (r range: .29 to .49; p < 0.01). At session 2, a significant correlation was found between processor technology type and the LNT-50 scores (r = .38; p < 0.01). Conclusions: Significant improvement in speech scores was observed between elementary grades and high school for children who had used a CI since preschool. On average, T levels (nC) and electrode function remained stable for these long-term pediatric users. Analyses of maps did not allow for the determination of the exact cause of C level reductions, though power limitations in new processor systems and changes in perceived loudness over time are possible. Larger EDRs and higher C levels were associated with better speech scores. Newer speech processor technology was associated with better speech scores at a softer level.


2007 ◽  
Vol 18 (09) ◽  
pp. 777-793 ◽  
Author(s):  
Laura K. Holden ◽  
Margaret W. Skinner ◽  
Marios S. Fourakis ◽  
Timothy A. Holden

The objective of this study was to evaluate the effect of the increased instantaneous input dynamic range (IIDR) in the Nucleus Freedom cochlear implant (CI) system on recipients' ability to perceive soft speech and speech in noise. Ten adult Freedom CI recipients participated. Two maps differing in IIDR were placed on each subject's processor at initial activation. The IIDR was set to 30 dB for one map and 40 dB for the other. Subjects used both maps for at least one month prior to speech perception testing. Results revealed significantly higher scores for words (50 dB SPL), for sentences in background babble (65 dB SPL), and significantly lower sound field threshold levels with the 40 compared to the 30 dB IIDR map. Ceiling effects may have contributed to non-significant findings for sentences in quiet (50 dB SPL). The Freedom's increased IIDR allows better perception of soft speech and speech in noise. El objetivo de este estudio fue evaluar el efecto del rango dinámico aumentado instantáneo de ingreso (IIDR) en el sistema de implante coclear (IC) Nucleus Freedom, sobre la capacidad de sujetos implantados para percibir lenguaje a bajo volumen y lenguaje en ruido. Diez sujetos implantados con el IC Freedom participaron. En la activación inicial, dos mapas con una diferencia en cuanto al IIDR se colocaron en el procesador de cada sujeto. El IIDR fue ajustado a 30 dB para un mapa y a 40 dB para el otro. Los sujetos utilizaron ambos mapas por al menos un mes, antes de una evaluación de percepción del lenguaje. Los resultados revelaron puntajes significativamente más altos para palabras (50 dB SPL), para frases en balbuceo de fondo (65 dB SPL), y niveles umbrales en campo libre significativamente más bajos con el mapa de IIDR de 40 comparado con el de 30. Efectos tope pueden haber contribuido a los hallazgos no significativos para frases en silencio (50 dB SPL). El IIDR aumentado para Freedom permite mejor percepción para el lenguaje a bajo volumen y el lenguaje en medio de ruido.


2005 ◽  
Vol 6 (S1) ◽  
pp. 31-34 ◽  
Author(s):  
Ricardo Ferreira Bento ◽  
Rubens Vuono De Brito Neto ◽  
Arthur Menino Castilho ◽  
M Valéria Schmidt Goffi Gomez ◽  
Sandra Barreto Giorgi Sant'anna ◽  
...  

2005 ◽  
Vol 6 (sup1) ◽  
pp. 31-34 ◽  
Author(s):  
Ricardo Ferreira Bento ◽  
Rubens Vuono De Brito Neto ◽  
Arthur Menino Castilho ◽  
M Valéria Schmidt Goffi Gomez ◽  
Sandra Barreto Giorgi Sant'anna ◽  
...  

2019 ◽  
Vol 69 (3) ◽  
Author(s):  
Tarek A. Ghannoum ◽  
Mona H. Selim ◽  
Amira M. El-Shennawy ◽  
Zahraa M. Elbohy

2010 ◽  
Vol 10 ◽  
pp. 329-339 ◽  
Author(s):  
Torsten Rahne ◽  
Michael Ziese ◽  
Dorothea Rostalski ◽  
Roland Mühler

This paper describes a logatome discrimination test for the assessment of speech perception in cochlear implant users (CI users), based on a multilingual speech database, the Oldenburg Logatome Corpus, which was originally recorded for the comparison of human and automated speech recognition. The logatome discrimination task is based on the presentation of 100 logatome pairs (i.e., nonsense syllables) with balanced representations of alternating “vowel-replacement” and “consonant-replacement” paradigms in order to assess phoneme confusions. Thirteen adult normal hearing listeners and eight adult CI users, including both good and poor performers, were included in the study and completed the test after their speech intelligibility abilities were evaluated with an established sentence test in noise. Furthermore, the discrimination abilities were measured electrophysiologically by recording the mismatch negativity (MMN) as a component of auditory event-related potentials. The results show a clear MMN response only for normal hearing listeners and CI users with good performance, correlating with their logatome discrimination abilities. Higher discrimination scores for vowel-replacement paradigms than for the consonant-replacement paradigms were found. We conclude that the logatome discrimination test is well suited to monitor the speech perception skills of CI users. Due to the large number of available spoken logatome items, the Oldenburg Logatome Corpus appears to provide a useful and powerful basis for further development of speech perception tests for CI users.


2021 ◽  
Vol 11 (2) ◽  
pp. 220-226
Author(s):  
Yew-Song Cheng ◽  
Mario A. Svirsky

The presence of spiral ganglion cells (SGCs) is widely accepted to be a prerequisite for successful speech perception with a cochlear implant (CI), because SGCs provide the only known conduit between the implant electrode and the central auditory system. By extension, it has been hypothesized that the number of SGCs might be an important factor in CI outcomes. An impressive body of work has been published on findings from the laborious process of collecting temporal bones from CI users and counting the number of SGCs to correlate those numbers with speech perception scores, but the findings thus far have been conflicting. We performed a meta-analysis of all published studies with the hope that combining existing data may help us reach a more definitive conclusion about the relationship between SGC count and speech perception scores in adults.


1993 ◽  
Vol 94 (6) ◽  
pp. 3178-3189 ◽  
Author(s):  
R. J. M. van Hoesel ◽  
Y. C. Tong ◽  
R. D. Hollow ◽  
G. M. Clark

Sign in / Sign up

Export Citation Format

Share Document