INFLAMMATION AT THE INSERTION SITE IS NOT PREDICTIVE OF CATHETER-RELATED BLOODSTREAM INFECTION WITH SHORT-TERM, NONCUFFED CENTRAL VENOUS CATHETERS

2002 ◽  
Vol 11 (7) ◽  
pp. 422
Author(s):  
&NA;
2008 ◽  
Vol 29 (3) ◽  
pp. 243-249 ◽  
Author(s):  
Jeffery S. Garland ◽  
Colleen P. Alex ◽  
Jackie M. Sevallius ◽  
Dawn M. Murphy ◽  
Mary J. Good ◽  
...  

Objective.To better define the pathogenesis of catheter-related bloodstream infection (BSI) in neonates with peripherally inserted central venous catheters (PICCs) to guide the development of more effective strategies for prevention.Design.Prospective nested cohort study.Setting.Level III neonatal intensive care unit in a community hospital.Methods.During a randomized trial to assess the safety and efficacy of a prophylactic vancomycin-heparin catheter-lock solution for the prevention of catheter-related BSI in neonates with PICCs, we performed cultures of peripheral and catheter-drawn blood samples, and quantitative cultures of catheter hub samples if BSI was suspected clinically. We performed semiquantitative cultures of the catheter tip and the catheter hub and the skin at the insertion site when the catheter was removed. Molecular subtyping by pulsed-field electrophoresis was used to determine the probable pathogenesis of all BSIs due to coagulase-negative staphylococci (CoNS); for BSIs caused by other microorganisms, epidemiologic concordance was based on speciation and antibiograms. Catheter-related BSI was considered extraluminally acquired if concordance was demonstrable solely between isolates recovered from the catheter tip and the blood, independent of concordance with isolates recovered from the insertion site. Catheter-related BSI was considered intraluminally acquired if concordance was demonstrated only between isolates recovered from the catheter hub and the blood. The source of the infection was considered indeterminate if both concordance patterns were present.Results.Nosocomial BSI was identified in 23 of the 82 neonates in the cohort. Fifteen of these infections, 14 of which were caused by CoNS, were considered definite or probable catheter-related BSIs. Catheter-related BSI was intraluminally acquired in 10 (67%) of 15 patients, extraluminally acquired in 3 (20%), and indeterminate in 2 (13%).Conclusions.Most catheter-related BSIs in neonates with PICCs are caused by CoNS and derive from intraluminal contamination. Strategies for prevention of catheter-related BSI directed at this predominant mechanism of infection are most likely to be effective.


2009 ◽  
Vol 30 (7) ◽  
pp. 698-701 ◽  
Author(s):  
Stefania Bezzio ◽  
C. Scolfaro ◽  
R. Broglia ◽  
R. Calabrese ◽  
F. Mignone ◽  
...  

This prospective observational study was designed to assess the incidence of, risk factors for, and outcome of catheter-related bloodstream infection in children undergoing cardiac surgery. A staff specifically trained to handle the central venous catheters with proper aseptic techniques and an appropriate patient to medical staff ratio remain the most effective measures to prevent this infection.


2003 ◽  
Vol 31 (1) ◽  
pp. 52-59 ◽  
Author(s):  
Marco Ranucci ◽  
Giuseppe Isgrò ◽  
Pier Paolo Giomarelli ◽  
Marco Pavesi ◽  
Aldo Luzzani ◽  
...  

2019 ◽  
Vol 7 (1) ◽  
Author(s):  
Michael Koeppen ◽  
Franziska Weinert ◽  
Sabrina Oehlschlaeger ◽  
Andreas Koerner ◽  
Peter Rosenberger ◽  
...  

Abstract Background In the critically ill, catheter-related bloodstream infection can result from bacterial contamination of infusion hubs of intravascular catheters. Needle-free connectors (NFC) have been suggested to reduce the rate of bacterial contamination and subsequent catheter-related bloodstream infection (CRBSI), but data remains ambiguous. Thus, we tested if a novel NFC would reduce bacterial contamination and subsequent CRBSI. Results In a prospective, randomized controlled trial, surgical ICU patients were randomized to three-way hubs closed by caps or Bionecteur® (Vygon, Inc.) of central venous catheters. Every 72 h, infusion lines were renewed and microbiological samples were taken. Bacterial growth was analyzed by blinded microbiologists. Incidence of bacterial contamination and CRSBI were assessed. Outcome parameters like length of stay on ICU and outcome were retrospectively assessed. Two thousand seven hundred patients were screened, 111 were randomized to the NFC, and 109 into the control group. Finally, 24 patients in the NFC and 23 control patients were analyzed. The majority of samples (NFC 77%; control 70%) found no bacterial growth. Coagulase-negative staphylococci were most commonly detected on CVC samples (NFC 17%; control 21%). We found CRBSI (defined as identical pathogens in blood culture and catheter line tip culture, and clinical manifestations of infection) in two control patients and one patient of the NFC group. Their length of ICU stay did not differ between groups (NFC 19 days; control 23 days). Conclusion The use of NFC does not influence the rate of bacterial contamination of infusion hubs of central venous catheters. Trial registration Clinicaltrials.gov, NCT02134769. Registered 09 May 2014.


Sign in / Sign up

Export Citation Format

Share Document