Predictability of Speech-In-Noise Performance from Real Ear Measures of Directional Hearing Aids

2004 ◽  
Vol 25 (2) ◽  
pp. 147-158 ◽  
Author(s):  
Sumitrajit Dhar ◽  
Larry E. Humes ◽  
Lauren Calandruccio ◽  
Nancy N. Barlow ◽  
Nicholas Hipskind
2002 ◽  
Vol 13 (06) ◽  
pp. 295-307 ◽  
Author(s):  
Mary T. Cord ◽  
Rauna K. Surr ◽  
Brian E. Walden ◽  
Laurel Olson

This study explored the use patterns and benefits of directional microphone technology in real world situations experienced by patients who had been fitted with switchable omnidirectional/directional hearing aids. Telephone interviews and paper-and-pencil questionnaires were used to assess perceived performance with each microphone type in a variety of listening situations. Patients who used their hearing aids regularly and switched between the two microphone configurations reported using the directional mode, on average, about one-quarter of the time. From brief descriptions, patients could identify listening situations in which each microphone mode should provide superior performance. Further, they reported encountering listening situations in which an omnidirectional microphone should provide better performance more frequently than listening situations in which the directional microphones should be superior. Despite using the omnidirectional mode more often and encountering situations in which an omnidirectional microphone should provide superior performance more frequently, participants reported the same level of satisfaction with each microphone type.


2005 ◽  
Vol 26 (02) ◽  
pp. 78-80
Author(s):  
Jennifer E Weber

2002 ◽  
Vol 11 (1) ◽  
pp. 29-41 ◽  
Author(s):  
Todd Ricketts ◽  
Paula Henry

Hearing aids currently available on the market with both omnidirectional and directional microphone modes often have reduced amplification in the low frequencies when in directional microphone mode due to better phase matching. The effects of this low-frequency gain reduction for individuals with hearing loss in the low frequencies was of primary interest. Changes in sound quality for quiet listening environments following gain compensation in the low frequencies was of secondary interest. Thirty participants were fit with bilateral in-the-ear hearing aids, which were programmed in three ways while in directional microphone mode: no-gain compensation, adaptive-gain compensation, and full-gain compensation. All participants were tested with speech in noise tasks. Participants also made sound quality judgments based on monaural recordings made from the hearing aid. Results support a need for gain compensation for individuals with low-frequency hearing loss of greater than 40 dB HL.


2005 ◽  
Vol 26 (02) ◽  
pp. 81-86
Author(s):  
Ruth Bentler ◽  
M. Samantha Lewis ◽  
Todd Ricketts ◽  
Brian E Walden

1999 ◽  
Vol 8 (2) ◽  
pp. 117-127 ◽  
Author(s):  
Todd Ricketts ◽  
H. Gustav Mueller

We have witnessed a large increase in the availability of directional microphone hearing aids over the past few years. Directional microphone technology is now available in analog, digitally controlled analog, and digital hearing aids, and has been implemented into both behind-the-ear and in-the-ear styles. This Short Course reviews basic design differences across directional microphone hearing aids. A number of different laboratory and clinical evaluation methods used for assessment of both electroacoustic and behavioral directivity are then reviewed. In addition, the potential impact of test conditions such as room reverberation and type and position of competing noise(s), on listener performance when fit with directional hearing aids are considered. Recommendations and suggestions relating to the clinical and laboratory assessment of directional hearing aids are provided.


2004 ◽  
Vol 15 (05) ◽  
pp. 365-396 ◽  
Author(s):  
Brian E. Walden ◽  
Rauna K. Surr ◽  
Mary T. Cord ◽  
Ole Dyrlund

Seventeen hearing-impaired adults were fit with omnidirectional/directional hearing aids, which they wore during a four-week trial. For each listening situation encountered in daily living during a total of seven days, participants selected the preferred microphone mode and described the listening situation in terms of five environmental variables, using a paper and pencil form. Results indicated that hearing-impaired adults typically spend the majority of their active listening time in situations with background noise present and surrounding the listener, and the signal source located in front and relatively near. Microphone preferences were fairly evenly distributed across listening situations but differed depending on the characteristics of the listening environment. The omnidirectional mode tended to be preferred in relatively quiet listening situations or, in the presence of background noise, when the signal source was relatively far away. The directional mode tended to be preferred when background noise was present and the signal source was located in front of and relatively near the listener. Results suggest that knowing only signal location and distance and whether background noise is present or absent, omnidirectional/directional hearing aids can be set in the preferred mode in most everyday listening situations. These findings have relevance for counseling patients when to set manually switchable omnidirectional/directional hearing aids in each microphone mode, as well as for the development of automatic algorithms for selecting omnidirectional versus directional microphone processing.


Sign in / Sign up

Export Citation Format

Share Document