Complications Associated With Negative Pressure Reaming for Harvesting Autologous Bone Graft: A Case Series

2010 ◽  
Vol 24 (1) ◽  
pp. 46-52 ◽  
Author(s):  
Jason A Lowe ◽  
Gregory J Della Rocca ◽  
Yvonne Murtha ◽  
Frank A Liporace ◽  
Michael D Stover ◽  
...  
2017 ◽  
Vol 38 (5) ◽  
pp. 485-495 ◽  
Author(s):  
Riccardo D’Ambrosi ◽  
Camilla Maccario ◽  
Chiara Ursino ◽  
Nicola Serra ◽  
Federico Giuseppe Usuelli

Background: The purpose of this study was to evaluate the clinical and radiologic outcomes of patients younger than 20 years, treated with the arthroscopic-talus autologous matrix-induced chondrogenesis (AT-AMIC) technique and autologous bone graft for osteochondral lesion of the talus (OLT). Methods: Eleven patients under 20 years (range 13.3-20.0) underwent the AT-AMIC procedure and autologous bone graft for OLTs. Patients were evaluated preoperatively (T0) and at 6 (T1), 12 (T2), and 24 (T3) months postoperatively, using the American Orthopaedic Foot & Ankle Society Ankle and Hindfoot (AOFAS) score, the visual analog scale and the SF-12 respectively in its Mental and Physical Component Scores. Radiologic assessment included computed tomographic (CT) scan, magnetic resonance imaging (MRI) and intraoperative measurement of the lesion. A multivariate statistical analysis was performed. Results: Mean lesion size measured during surgery was 1.1 cm3 ± 0.5 cm3. We found a significant difference in clinical and radiologic parameters with analysis of variance for repeated measures ( P < .001). All clinical scores significantly improved ( P < .05) from T0 to T3. Lesion area significantly reduced from 119.1 ± 29.1 mm2 preoperatively to 77.9 ± 15.8 mm2 ( P < .05) at final follow-up as assessed by CT, and from 132.2 ± 31.3 mm2 to 85.3 ± 14.5 mm2 ( P < .05) as assessed by MRI. Moreover, we noted an important correlation between intraoperative size of the lesion and body mass index (BMI) ( P = .011). Conclusions: The technique can be considered safe and effective with early good results in young patients. Moreover, we demonstrated a significant correlation between BMI and lesion size and a significant impact of OLTs on quality of life. Level of Evidence: Level IV, retrospective case series.


2020 ◽  
pp. 193864002091626
Author(s):  
Farough Khademi ◽  
Amirhossein Erfani ◽  
Mohammad Ali Erfani ◽  
Amir Reza Vosoughi

Background: The aim of this study was to evaluate the complications following calcaneal autologous bone graft harvesting using an osteotome in patients who underwent foot and ankle surgery with follow-up of at least 1 year. Methods: In a cohort study, all consecutive patients underwent forefoot or midfoot surgeries in conjunction with harvesting bone graft from the calcaneus using lateral wall corticotomy technique by an osteotome from 2015 till 2018 were asked to follow. The outcome and morbidity were assessed by visual analogue scale (VAS) pain, numbness in territory of the sural nerve, surgical site numbness or tenderness, infection, hematoma formation, or pathologic fracture. Also any possible restrictions on wearing desired shoes were asked. Results: Totally, 50 patients (11 males, 39 females; 29 right foot, 21 left foot) with the mean age of 48.2 ± 13.8 years (range 8-66 years) were assessed. There were no major complications on donor site such as infection, hematoma formation, or pathologic fracture. The following results were seen; 90% without any pain (VAS 0/10), 96% without numbness at the incision site, 96% without point tenderness on lateral of heel, 98% without paresthesia or numbness in the sural nerve territory, and 84% were able to wear their favorite shoes. Forty-one (82%) cases said if they need another foot surgery, they would permit to harvest bone graft from their heel. Conclusions: Autologous bone graft harvesting from the calcaneus using lateral wall corticotomy technique by an osteotome could be a useful method with very low complications. Levels of Evidence: Therapeutic, level IV: cohort, case series


2019 ◽  
Vol 4 (3) ◽  
pp. 247301141987403
Author(s):  
Dimitrios Nikolopoulos ◽  
Neoptolemos Sergides ◽  
George Safos ◽  
Konstantinos Moustakas ◽  
Petros Safos ◽  
...  

Background: The treatment of large osteochondral lesions of the talus (OLTs) is challenging due to the poor intrinsic reparative capability of the damaged articular cartilage. Autologous transfer of bone and periosteum has been used successfully in the treatment of large defects in animals, and therefore it was believed that this technique might show similar results in humans. The purpose of this study was to assess the outcome of an innovative technique for autologous transplantation of cancellous tibial graft with periosteal transfer in large OLTs. Methods: Forty-one patients (22 females, 19 males), with a mean age of 34.9 years (range, 18-72 years), with a large OLT (>200 mm2) were treated with autologous bone graft and periosteum transfer. OLTs averaging 310 mm2 were identified on a preoperative computed tomography scan. The procedure consisted of malleolar osteotomy, curettage of sclerotic bone, autologous bone graft from the proximal tibia, and transfixion of periosteum over the graft. Outcome measures, including the pain visual analog scale (VAS), ankle range of motion (ROM), American Orthopaedic Foot & Ankle Society (AOFAS) score, and Foot & Ankle Disability Index (FADI), were compared between preoperative and 1 and 2 years following surgery. Results: There were significant improvements in VAS pain score from 7.7 before surgery to 1.1 at 1 year after surgery and 0.4 at 2 years or more after surgery. The AOFAS and FADI scores were also significantly improved from 40.3 and 53.3 preoperatively to 95 and 93.2 postoperatively at 1 year and 95 and 93.2 at 2 or more years postoperatively, respectively. Postoperative complications included 2 patients who required removal of medial malleolar osteotomy tension bands due to symptomatic hardware. There were no nonunions or malunions of the osteotomies and no donor site complications. Conclusion: Autologous bone graft and periosteum transfer was an effective treatment for large OLTs leading to significant decreases in pain and improvement in functional scores at more than 2 years after surgery. Level of Evidence: Level IV, retrospective case series.


Orthopedics ◽  
2012 ◽  
Author(s):  
Hui-Kuang Huang ◽  
Chao-Ching Chiang ◽  
Yu-Ping Su ◽  
Chi-Kuang Feng ◽  
Fang-Yao Chiu ◽  
...  

2018 ◽  
Vol 100-B (12) ◽  
pp. 1609-1617 ◽  
Author(s):  
A. M. Malhas ◽  
J. Granville-Chapman ◽  
P. M. Robinson ◽  
S. Brookes-Fazakerley ◽  
M. Walton ◽  
...  

Aims We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency. Patients and Methods A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection. Results Of the 45 patients, 16 had anatomical shoulder arthroplasties (ASA) and 29 had reverse shoulder arthroplasties (RSA). Postoperatively, 43/45 patients had a CT scan. In 41 of 43 patients (95%), the glenoid peg achieved > 50% integration. In 40 of 43 cases (93%), the graft was fully or partially integrated. There were seven revisions (16%) but only four (9%) required a change of baseplate. Four (25%) of the 16 ASAs were revised for instability or cuff failure. At two-year radiological follow-up, five of the 41 cases (11%) showed some evidence of lucent lines. Conclusion The use of a metal baseplate with a trabecular titanium surface in conjunction with autologous bone graft is a reliable method of addressing glenoid bone defects in primary and revision RSA setting in the short term. ASAs have a higher rate of complications with this technique.


2018 ◽  
Vol 26 (3) ◽  
pp. 230949901879953 ◽  
Author(s):  
Uriel Giwnewer ◽  
Guy Rubin ◽  
Eithan Dohovni ◽  
Nimrod Rozen ◽  
Noam Bor

Background: Congenital pseudoarthrosis of the clavicle (CPC) is rare and may require treatment, usually because of an unacceptable appearance or occasionally because of pain in an adolescent patient. Spontaneous union is unknown, and consequently any desired union requires open reduction and bone grafting. Many authors recommend performing the operation at the age of 3–5 years and using different fixation methods. We present our experience with three cases and literature review in an attempt to further elucidate the appropriate timing of the procedure and the fixation method. Methods: This was a retrospective review of three cases presenting with pseudoarthrosis of the clavicle. All cases were treated by curettage of the pseudoarthrosis, with the void filled using full-thickness ileac crest autologous bone graft and bridging plate—one compression and two anatomical, at different ages. We performed a literature review with emphasis on timing of the procedure, fixation method and complications. Results: All patients healed with good callus formation. One patient (5-year-old female treated using a compression plate) experienced overlying skin irritation and underwent removal of the plate. There were no restriction of movement, pain or any other complaint on the final follow-up. We did not find any difference in the operating complexity at different ages, but when a compression plate was used, it had to be removed later due to bulging of the plate. Discussion: No clinical difference was observed between earlier and late operation. Therefore, we suggest performing a curettage of the pseudoarthrosis, gapping the void using autologous bone graft, and using an anatomical bridging plate.


Sign in / Sign up

Export Citation Format

Share Document