Sore throat with nondeflated versus deflated supreme laryngeal mask airway

2022 ◽  
Vol 39 (2) ◽  
pp. 186
Author(s):  
Priya Rudingwa ◽  
Sakthi Rajan Panneerselvam ◽  
Aswini Kuberan
2021 ◽  
pp. 102595
Author(s):  
kourosh Farazmehr ◽  
Mohamad Aryafar ◽  
Farshid Gholami ◽  
Giti Dehghanmanshadi ◽  
Seyed Sepideh Hosseini

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Erol Karaaslan ◽  
Sedat Akbas ◽  
Ahmet Selim Ozkan ◽  
Cemil Colak ◽  
Zekine Begec

Abstract Background There are doubts among anesthesiologists on the use of the Laryngeal Mask Airway (LMA) in nasal surgeries because of concerns about the occurrence of blood leakages to the airway. We hypothesized that the use of LMA-Supreme (LMA-S) in nasal surgery is comparable with endotracheal tube (ETT) according to airway protection against blood leakage through the fiberoptic bronchoscopy, oropharyngeal leakage pressure (OLP), heart rate (HR), mean arterial pressure (MAP), and postoperative adverse events. Methods The present study was conducted in a prospective, randomized, single-blind, controlled manner on 80 patients, who underwent septoplasty procedures under general anesthesia, after dividing them randomly into two groups according to the device used (LMA-S or ETT). The presence of blood in the airway (glottis/trachea, distal trachea) was analyzed with the fiberoptic bronchoscope and a four-point scale. Both groups were evaluated for OLP; HR; MAP; postoperative sore throat, nausea, and vomiting; dysphagia; and dysphonia. Results In the fiberoptic evaluation of the airway postoperatively, less blood leakage was detected in both anatomic areas in the LMA-S group than in the ETT group (glottis/trachea, p = 0.004; distal trachea, p = 0.034). Sore throat was detected less frequently in the LMA-S group at a significant level in the 2nd, 6th, and 12th hours of postoperative period; however, other adverse events were similar in both groups. Hemodynamic parameters were not different between the two groups. Conclusion The present findings demonstrate that the LMA-S provided more effective airway protection than the ETT in preventing blood leakage in the septoplasty procedures. We believe that the LMA-S can be used safely and as an alternative to the ETT in septoplasty cases. Trial registration This trial is registered at the US National Institutes of Health (ClinicalTrials.gov) # NCT03903679 on April 5, 2019.


2021 ◽  
Vol 15 (12) ◽  
pp. 3232-3235
Author(s):  
M. J. Ahmed Kamal ◽  
Baber Zaheer ◽  
Naveed Ahmed Durrani ◽  
Khaleel Ahmad ◽  
Sumara Tabassam ◽  
...  

Background: In case of general anesthesia, airway maintenance along with least complications is the most important goal of team of anesthesiologists. In case of clinical practice, the laryngeal mask airway (LMA) devices have superiority in managing supraglottic airway. Recently i-gel airway has been introduced as supraglottic airway equipment (disposable). Aim: To make comparison between laryngeal mask and I-gel with respect to postoperative complication of sore throat in case of patients who were given general anesthesia. Study design: Randomized trial Setting: Anesthesia Department Study duration: 6 after synopsis approval in total 6months of duration Methods: Candidates were divided randomly divided into two groups. In case of members of group A, patients were given i-gel where as members of group B, disposable LMA was given. General anesthesia was administered according to the standardized protocols. A day after operation, candidates were check post operatively for 24 hours, for sore throat and information was documented on Performa. Results: The candidates mean age was 44.23±15.11years in case of i-gel group members whereas 46.10±15.56 years in case of LMA group. In case of i-gel group, there were about twenty five males members and thirty five were females members . In case of LMA group members, there were about twenty six males and thirty four female members . In present case research, sore throat postoperatively was seen in case of 17(14.2%) cases, i.e. 4 (6.7%) in i-gel group while 13(21.7%) in case of LMA group. The significant difference was witnessed between members of both groups (p<0.05). Conclusion: Thus i-gel is better than LMA for general anesthesia as it has fewer chances of side effects like postoperative sore throat. Keywords: Postoperative sore throat, I-gel, laryngeal mask airway, general anesthesia


2003 ◽  
Vol 99 (5) ◽  
pp. 1066-1071 ◽  
Author(s):  
André A. J. van Zundert ◽  
Kristine Fonck ◽  
Baha Al-Shaikh ◽  
Eric Mortier

Background The laryngeal mask airway LMA-Classic has been used widely in clinical practice. A new disposable supraglottic airway device, the Soft Seal LM, has been introduced recently. In a randomized study, the authors compared the LMA-Classic and the disposable Soft Seal LM in terms of their clinical performance, cuff pressures during nitrous oxide anesthesia, position of the laryngeal mask in situ by fiberoptic evaluation, and morbidity in a wide range of routine general surgery procedures. Methods A total of 200 adult patients were randomly assigned to a size 4 laryngeal mask in two equal-sized groups for airway management during surgery: (1) LMA-Classic (Intavent Orthofix Ltd., Maidenhead, Berkshire, United Kingdom); or (2) Soft Seal LM (Portex Ltd., Hythe, Kent, United Kingdom). Anesthesia was administered with fentanyl, propofol, nitrous oxide, oxygen, and sevoflurane. The variables studied were ease of insertion, fiberoptic view, time in situ, incidence of blood on the laryngeal mask at the time of removal, and the incidence of postoperative sore throat at 2 and 24 h. The laryngeal mask cuff pressures were measured continuously. Intracuff pressure limitation was not attempted. Results The LMA-Classic and the Soft Seal LM showed similar clinical performances, as shown by their insertion time (successful insertion at first attempt was achieved within 20 s in 97% with LMA-Classic trade mark vs. 95% with Soft Seal LM), fiberoptic evaluation of the anatomic position of the laryngeal mask, and satisfactory anesthesia conditions. Laryngeal mask cuff pressures increased from 45 to 100.3 mmHg in the LMA-Classic and from 45 to 46.8 mmHg in the Soft Seal LM (P &lt; 0.001). Macroscopic blood was seen on only four occasions in the LMA-Classic group. The incidence of sore throat was significantly increased at 2 h postoperatively when using the LMA-Classic, although there was no difference at 24 h after surgery. Conclusions In spontaneously breathing adult patients requiring a size 4 laryngeal mask airway, the new disposable Soft Seal LM device is an acceptable alternative to the reusable LMA-Classic trade mark, resulting in a good laryngeal seal and offering similar clinical performance. Cuff pressures increase substantially when the LMA-Classic is used but not when using the Soft Seal LM. There was less trauma to patients using the Soft Seal LM, as assessed by the incidence of sore throat in the early postoperative period.


2019 ◽  
Author(s):  
Yahong Gong ◽  
Xiaohan Xu ◽  
Jin Wang ◽  
Lu Che ◽  
Weijia Wang ◽  
...  

Abstract BackgroundSore throat is a remarkable complication after thyroid surgery with endotracheal tube (ETT). Many studies revealed that laryngeal mask airway (LMA) might reduce the incidence and severity of postoperative sore throat. However, little is known about the use of a flexible reinforced LMA (FLMA) in thyroid surgery. The purpose of this study was to explore the potential benefits of FLMA compared with ETT on postoperative sore throat.MethodsIn this prospective, single-blinded, randomized, controlled trial, ninety-six patients aged 20-80 years, scheduled for elective radical thyroidectomy under general anesthesia were enrolled. They were randomly divided into ETT group and FLMA group. All the included patients received total intravenous anesthesia (with propofol, fentanyl and rocuronium) and controlled mechanical ventilation during the surgery. Cuff pressure of ETT and FLMA were strictly controlled. Incidence and severity of postoperative sore throat, numbness and hoarseness at 1, 24, and 48 h after surgery was evaluated and compared between the two groups. Incidence and severity of buckling during extubation and the hemodynamic profile during intubation were also recorded and compared.ResultsThe incidence of sore throat and hoarseness was significantly lower in FLMA group than those in ETT group at 1h, 24h and 48h postoperatively, as well as the severity of sore throat. Compared to ETT group, there was a significantly lower incidence of buckling during extubation and less fluctuation of HR and BP at 1min and 3min after intubation in FLMA group.ConclusionsPostoperative sore throat and hoarseness was improved in patients undergoing thyroid surgery with FLMA when compared with ETT. The use of FLMA also achieved less buckling during extubation and better hemodynamic profiles during intubation.


Sign in / Sign up

Export Citation Format

Share Document