Discrepancies in Endothelial Cell Density Values of Human Donor Corneas Resulting From Comparison Between Specular Microscopes and Endothelial Analysis Methods

Cornea ◽  
2020 ◽  
Vol 39 (4) ◽  
pp. 495-500
Author(s):  
Yue Shi ◽  
Jianyan Huang ◽  
Patrick Conrick ◽  
Caroline Hoover ◽  
Olivia L. Lee
Author(s):  
Bhuvaneshwari Namitha ◽  
Munusamy Rajendran Chitra ◽  
Mathevan Bhavya ◽  
Periasamy Parikumar ◽  
Shojiro Katoh ◽  
...  

Abstract Purpose McCarey-Kaufman’s (MK) medium and Optisol-GS medium are the most commonly employed media for human donor corneal preservation. In this study, we evaluated the preservation efficacy of discarded human donor corneas using a Thermo-reversible gelation polymer (TGP) added to these two media. Methods Thirteen human corneal buttons collected from deceased donors, which were otherwise discarded due to low endothelial cell density (ECD) were used. They were stored in four groups: MK medium, MK medium with TGP, Optisol-GS and Optisol-GS with TGP at 4 °C for 96 h. Slit lamp examination and specular microscopy were performed. Corneal limbal tissues from these corneas were then cultured using explant methodology one with and the other without TGP scaffold, for 21 days. Results MK + TGP and Optisol-GS + TGP preserved corneas better than without TGP, which was observed by maintenance of ECD which was significantly higher in Optisol-GS + TGP than MK + TGP (p-value = 0.000478) and corneal thickness remaining the same for 96 h. Viable corneal epithelial cells could be grown from the corneas stored only in MK + TGP and Optisol-GS + TGP. During culture, the TGP scaffold helped maintain the native epithelial phenotype and progenitor/stem cell growth was confirmed by RT-PCR characterization. Conclusion TGP reconstituted with MK and Optisol—GS media yields better preservation of human corneal buttons in terms of relatively higher ECD maintenance and better in vitro culture outcome of corneal limbal tissue. This method has the potential to become a standard donor corneal transportation-preservation methodology and it can also be extended to other tissue or organ transportation upon further validation.


2017 ◽  
Vol 47 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Dhaval Patel ◽  
Radhika Tandon ◽  
Anita Ganger ◽  
Aarti Vij ◽  
Sanjeev Lalwani ◽  
...  

To evaluate the impact of death-to-preservation time (DPT) on effective utilisation of donor corneas. In a prospective observational study conducted at our tertiary eye centre, donated corneas received over a 15-month period from November 2011 to January 2013 were evaluated. Donor age, donor refrigeration (done or not), DPT, endothelial cell density (ECD), corneal grading, clinical utilisation and surgical outcome after graft transplantation were noted. To analyse the impact of different DPT on donor cornea transplantation, primary outcome measures (corneal grading and endothelial cell density) and secondary outcome measures (primary graft failure and graft infection) were analysed. A total of 990 corneas were assessed. Primary outcomes showed no significant difference for higher DPT ( P > 0.01). ECD, where DPT was >12 h, was better for refrigerated corneas ( P < 0.001). Prolonged DPT had no significant effect on primary graft failure ( P = 0.131) and graft infection ( P = 0.137) in the first month after transplantation. We find that DPT should not be the only criteria to assess the cornea quality; other donor characteristics should be considered equally important. Donor refrigeration should be encouraged in cases where early retrieval is not possible.


PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0260523
Author(s):  
Sai Kyauk ◽  
Howard Y. Cajucom-Uy ◽  
Hla Myint Htoon ◽  
Z. Zaw Htoi Aung ◽  
Jodhbir S. Mehta ◽  
...  

Purpose To compare the utilization rate and usage patterns of pseudophakic and phakic donor corneas recovered by the Singapore Eye Bank. Methods Records of local donor corneas recovered by the Singapore Eye Bank from 2012 to 2017 were examined. Corneas that were deemed suitable for clinical use were stratified into phakic and pseudophakic groups. We examined the basic demographic pattern of both groups and the initial type of surgery/ies that the corneas were suitable for based on tissue parameters such as time from harvesting, stromal clarity, the clear central corneal area, the presence of Descemet’s membrane tears or defects, and endothelial cell density and quality. We also identified the types of corneal grafts that the corneas were eventually used for; Penetrating Keratoplasty (PK), Anterior Lamellar Keratoplasty (ALK), Endothelial Keratoplasty (EK). Finally, the overall utilization rates for each group were determined. Results A total of 986 corneas deemed suitable for transplant were analyzed, 908 (92%) were phakic and 78 were pseudophakic (8%). The average age of pseudophakic donor corneas was (65 ± 8 yrs. old) and there was a slight male preponderance for both groups (55%). Age adjusted analysis of pseudophakic corneas showed the endothelial cell density (ECD) (mean: 2327 ± 47.1 cells/mm2) and clear area (mean: 7.0 ± 0.7 mm) were lesser than phakic corneas. The percentage of pseudophakic corneas that were of EK standard (ECD >2500 cells/mm2) were lower compared to phakic corneas (37% and 77% respectively, p < 0.001). There was significant correlation between previous cataract surgery and the endothelial cell count of the donor corneas (p < 0.001), and regression analysis also showed a strong association of ECD with cataract surgery in reference to non-cataract surgery (-478.8 (95% CI-576.9 to -380.7). The overall utilization rate for pseudophakic corneas was 58% compared to that of phakic corneas at 83%. The most common reason for pseudophakic corneas not to be utilized was due to the presence of Descemet’s membrane (DM) tears or defects under the main or side port incision created during phacoemulsification (30%). Phakic corneas were used primarily for optical grafts 84% (mainly EK) while pseudophakic corneas were used mostly for therapeutic/tectonic grafts 47% (mainly ALK or patch grafts). Conclusion Compared to phakic donor corneas, pseudophakic corneas generally have lower overall tissue quality leading to lower uptake by surgeons and lower utilization rates. Eye banks must continuously refine their donor acceptance criteria and engage surgeons to optimize utilization of each recovered tissue.