eye bank
Recently Published Documents


TOTAL DOCUMENTS

267
(FIVE YEARS 59)

H-INDEX

26
(FIVE YEARS 2)

PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0260523
Author(s):  
Sai Kyauk ◽  
Howard Y. Cajucom-Uy ◽  
Hla Myint Htoon ◽  
Z. Zaw Htoi Aung ◽  
Jodhbir S. Mehta ◽  
...  

Purpose To compare the utilization rate and usage patterns of pseudophakic and phakic donor corneas recovered by the Singapore Eye Bank. Methods Records of local donor corneas recovered by the Singapore Eye Bank from 2012 to 2017 were examined. Corneas that were deemed suitable for clinical use were stratified into phakic and pseudophakic groups. We examined the basic demographic pattern of both groups and the initial type of surgery/ies that the corneas were suitable for based on tissue parameters such as time from harvesting, stromal clarity, the clear central corneal area, the presence of Descemet’s membrane tears or defects, and endothelial cell density and quality. We also identified the types of corneal grafts that the corneas were eventually used for; Penetrating Keratoplasty (PK), Anterior Lamellar Keratoplasty (ALK), Endothelial Keratoplasty (EK). Finally, the overall utilization rates for each group were determined. Results A total of 986 corneas deemed suitable for transplant were analyzed, 908 (92%) were phakic and 78 were pseudophakic (8%). The average age of pseudophakic donor corneas was (65 ± 8 yrs. old) and there was a slight male preponderance for both groups (55%). Age adjusted analysis of pseudophakic corneas showed the endothelial cell density (ECD) (mean: 2327 ± 47.1 cells/mm2) and clear area (mean: 7.0 ± 0.7 mm) were lesser than phakic corneas. The percentage of pseudophakic corneas that were of EK standard (ECD >2500 cells/mm2) were lower compared to phakic corneas (37% and 77% respectively, p < 0.001). There was significant correlation between previous cataract surgery and the endothelial cell count of the donor corneas (p < 0.001), and regression analysis also showed a strong association of ECD with cataract surgery in reference to non-cataract surgery (-478.8 (95% CI-576.9 to -380.7). The overall utilization rate for pseudophakic corneas was 58% compared to that of phakic corneas at 83%. The most common reason for pseudophakic corneas not to be utilized was due to the presence of Descemet’s membrane (DM) tears or defects under the main or side port incision created during phacoemulsification (30%). Phakic corneas were used primarily for optical grafts 84% (mainly EK) while pseudophakic corneas were used mostly for therapeutic/tectonic grafts 47% (mainly ALK or patch grafts). Conclusion Compared to phakic donor corneas, pseudophakic corneas generally have lower overall tissue quality leading to lower uptake by surgeons and lower utilization rates. Eye banks must continuously refine their donor acceptance criteria and engage surgeons to optimize utilization of each recovered tissue.


2021 ◽  
Vol 19 (11) ◽  
pp. 1191-1196
Author(s):  
Emre Altinkurt ◽  
Zafer Cebeci ◽  
Ozkan Avci ◽  
Kemal Turgay Ozbilen ◽  
Nilufer Alparslan
Keyword(s):  
Eye Bank ◽  

2021 ◽  
Vol 8 ◽  
Author(s):  
Handan Tan ◽  
Meng Lin ◽  
Qingqing Gou ◽  
Aijia Li ◽  
Fengjuan Gu ◽  
...  

Aim: This study aimed to analyze corneal transplantation trends and voluntary donor characteristics at the Chongqing Eye Bank in China.Methods: We retrospectively reviewed and analyzed data from January 1, 1999, to December 31, 2018, covering 5,397 preregistered voluntary donors, 1,955 actual donors, 3,910 donated tissues, and 2,374 corneal transplantations.Results: The 5,397 preregistered donors included 13 ethnic groups, with an overall mean age of 39.6 years (SD 21.5) and 3,010 were women (55.8%). The most prevalent education level was college and above (2,546, 47.2%), and the most common ethnic group was Han (5,335, 98.85%). Of the 1,955 actual donors, the male-to-female ratio was 3.3, and the mean age was 57.1 (SD 23.0 years). Based on population size in 2018, Jiangbei county was the most active in donation willingness, with ~60 × 10−6 per capita, and the Yuzhong county was the most active in cornea donations, with ~451 × 0−6 per capita. Of the 3,910 donated corneas, 2,540 (65.0%) were clinically used. Of those not used, 978 (71.4%) were rejected for poor corneal quality. The 2,374 (93.5%) corneal transplantation procedures were done at the Department of Ophthalmology of the First Affiliated Hospital of Chongqing Medical University and the rest (n = 166, 6.5%) were performed in other centers. Of those 2,374 corneal transplantations, there were 1,671 penetrating keratoplasty (70.39%), 700 anterior lamellar keratoplasty (29.49%), and three corneal endothelial transplantations in our center (0.13%). The number of annual corneal transplantations increased by nearly 10 times, from 35 cases in 1999 to 327 cases in 2018. Among them, cases of penetrating keratoplasty and anterior lamellar keratoplasty increased from 27, and eight cases in 1999 to 230 and 94 cases in 2018, respectively. Infectious keratitis (37.0%) was the leading indication for keratoplasty, followed by corneal scar (19.8%). Over the study period, corneal scars dropped from the first (41.1% in 1999–2003) to the second indication (20.5% in 2014–2018), while infectious keratitis advanced to take the lead, ranging from 12.2% in 1999–2003 to 26.3% in 2014–2018.Conclusion: Our study reports corneal donation and transplantation trends in Chongqing over 20 years, showing that infectious keratitis is a leading indication for keratoplasty and that penetrating keratoplasty and anterior lamellar keratoplasty show upward trends. The analysis further suggests that a potential preregistered cornea donor is a female Han, with a higher education level.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Luca Pagano ◽  
Kunal A Gadhvi ◽  
Mohit Parekh ◽  
Giulia Coco ◽  
Hannah J Levis ◽  
...  

Abstract Background Selective lamellar corneal transplantation (keratoplasty) has overtaken full thickness penetrating keratoplasty as the graft choice for endothelial failure. Even more recently eye bank prepared tissues are becoming increasing popular as a way to reduce the risks of tissue loss and stress during endothelial keratoplasty preparation in the surgical theatre. This study compares costs between surgeon and eye bank prepared tissues for Descemet’s stripping automated endothelial keratoplasty (DSAEK) and Descemet’s membrane endothelial keratoplasty (DMEK). Methods Retrospective study conducted at the Royal Liverpool University Hospital including endothelial keratoplasties with a minimum of 6 months follow-up time. Cost analysis included surgical expenses, tissue acquisition fees, cost of patient’s ward admission and out-patient expenses, including cost of re-bubbling procedures, costs of visits, anterior segment imaging and optometrist visits within the first 6 months follow-up. Results Ninety-eight eyes of 98 patients were included in the study of which 42 underwent DSAEK surgery and 56 DMEK surgery. Cost analysis of surgical expenses in the DSAEK group showed a significant difference between using surgeon prepared and eye bank prepared tissue (£3866 ± 296 and £4389 ± 360, respectively; p < 0.01) and the same was found in the DMEK group (£3682 ± 167 and £4162 ± 167 for surgeon prepared and eye bank prepared tissues, respectively; p < 0.01). Cost of out-patient visits did not differ significantly in either group. Conclusions At the Royal Liverpool University Hospital, eye bank prepared tissues had higher surgical expenses compared to those prepared by the surgeon, while the post-operative care expenses were similar between the two groups.


2021 ◽  
Vol 10 (15) ◽  
pp. 3426
Author(s):  
Franziska Schön ◽  
Adrian Gericke ◽  
Julia Bing Bu ◽  
Melissa Apel ◽  
Alicia Poplawski ◽  
...  

Background: In Germany, more than one-third of donor corneas harvested are not suitable for transplantation. We evaluated the factors associated with the usability of donor corneas. Method: Data from 2032 consecutive donor corneas harvested at the Rhineland-Palatinate Eye Bank in Mainz, Germany, were retrospectively analyzed. Factors of interest were age, sex, lens status, cause of death, cardiopulmonary resuscitation (CPR), death-to-explantation-interval (DEI), and the influence of these factors on the proportion of discarded donor corneas. Factors associated with endothelial cell density (ECD) were analyzed in a linear regression mixed model. Results: Higher donor age, male gender, pseudophakic lens status, and longer DEI were associated with significantly reduced ECD. With respect to DEI, the estimated cell loss was 7 ± 2 cells/mm2/hour (p < 0.001). Age was associated with a lower ECD of 6 ± 2 cells/mm2 per year (p = 0.001). Female ECD was 189 ± 44 cells/mm2 higher than male ECD (p < 0.001). Pseudophakic eyes had 378 ± 42 cells/mm2 less compared with phakic eyes (p < 0.001). Cause of death did not affect the ECD. Of note, 55% and 38% of corneas harvested on the second and third postmortem day, respectively, and 45% of corneas from donors older than 80 years were still suitable for transplantation. Conclusions: In the context of a growing need for donor corneas, we do not recommend limiting donor age and collection time to 24 h or excluding oncology donors, as is the practice in many countries. Therefore, we propose a mathematical model for better donor preselection.


2021 ◽  
Vol 238 (06) ◽  
pp. 680-687
Author(s):  
Tarek Safi ◽  
Loay Daas ◽  
Gian-Luca Kiefer ◽  
Mansi Sharma ◽  
Alassane Ndiaye ◽  
...  

Abstract Background Cornea guttata may not be recognized in the eye bank and recent studies have displayed that guttae are transplanted in about 15% of cases in varying severities. The purpose of this study was to establish semiquantitative criteria for the detection of cornea guttata in donor corneas in the eye bank. Methods In this retrospective cohort study, preoperative endothelial pictures of donor corneas were collected and classified according to the post-penetrating keratoplasty cornea guttata grade into three distinct groups: group 1 consists of healthy corneas with no guttae (guttata grade 0); group 2 constitutes corneas with mild asymptomatic cornea guttata (guttata grade +); and group 3 comprises corneas with advanced widespread cornea guttata (guttata grade ++/+++/++++). The preoperative pictures of each group were then individually analyzed using the following five semiquantitative criteria: The number and the area of the cell-depleted surfaces, the presence of less than 50% of the cells having a hexagonal or a circular shape, the presence of cell membrane defects and interruptions, the presence of blebs in the cell membrane, and the presence of groups of cells with a distinct whitish color. Results In total, 262 patients were included in this study, with a total number of 1582 preoperative donor corneal endothelial pictures. Out of those pictures, groups 1, 2, and 3 encompassed 995 (62.9%), 411 (26.0%), and 176 (11.1%) pictures, respectively. Three out of the five eye bank criteria were found to correlate with postoperative cornea guttata with a highly significant p value of < 0.001. These three criteria are the presence of less than 50% of the cells having a hexagonal or a circular shape, the presence of cell membrane defects and interruptions and, the presence of blebs. The presence of groups of cells with a distinct whitish color was only a weak predictive factor for cornea guttata (p = 0.069). There was no statistically significant correlation between the number and the area of cell-depleted surfaces and postoperative cornea guttata with a p = 0.181. Conclusion Three semiquantitative criteria that can be detected in the eye bank using inverted light microscopy seem to correlate with postoperative cornea guttata: The presence of blebs, the presence of cell membrane defects and interruptions, as well as endothelial pictures with less than 50% of the cells having a hexagonal of circular shape. The presence of groups of cells with a distinct whitish color appears to be a weak predictor of cornea guttata.


2021 ◽  
Vol 238 (06) ◽  
pp. 688-692
Author(s):  
Adrien Quintin ◽  
Loïc Hamon ◽  
Stephanie Mäurer ◽  
Achim Langenbucher ◽  
Berthold Seitz

Abstract Background and Objective Sterile donor tomography enables the detection of corneal tissues with refractive anomalies. The aim of this study was to determine the curvature and thickness of donor corneas to support proper selection in the eye bank. Methods 704 donor corneas (Klaus Faber Center, LIONS Eye Bank Saar-Lor-Lux, Trier/Westpfalz, in Homburg/Saar) were measured using the anterior segment optical coherence tomograph (AS-OCT) CASIA 2 (Tomey Corp., Nagoya, Japan). The corneoscleral discs were measured in their cell culture flask, which was positioned in a holder on the chin rest of the AS-OCT, after conversion to medium II (with 6% dextran T-500). The measured raw data were analysed and processed in MATLAB (MathWorks Inc., Natick, Massachusetts, USA), after which the refractive power of the steep and flat meridian at the anterior and posterior surface and the central corneal thickness (CCT) of the donor corneas were determined. Results values are expressed as mean x̅ ± standard deviation SD. Results The mean refractive power of the steep/flat meridian at the anterior surface was 45.4 ± 1.8 D/44.0 ± 1.3 D, the corresponding values for the posterior surface were − 6.2 ± 0.3 D/− 5.9 ± 0.2 D, and the mean CCT was 616.3 ± 85.1 µm. Of the 704 (100%) measured donor tissues, 590 (83.8%)/670 (95.2%) donor corneas showed no anomaly beyond respectively x̅ ± 2 SD/x̅ ± 3 SD among the 5 examined parameters. 72 (10.3%)/23 (3.3%) donor corneas had only 1 anomaly, 26 (3.7%)/10 (1.4%) had 2 anomalies, 10 (1.4%)/1 (0.1%), 3 anomalies, 5 (0.7%)/0 (0.0%), 4 anomalies, and 1 (0.1%)/0 (0.0%), 5 anomalies. Conclusions AS-OCT provides an objective and sterile screening method to identify corneal tissues with curvature anomalies in order to further optimise donor selection in the eye bank. To avoid postoperative refractive surprises, donor corneas with a total refractive power that deviates > ± 3 SD from the mean should not be used for penetrating or anterior lamellar keratoplasty, but may be suitable for posterior lamellar keratoplasty (DMEK or DSAEK). In the future, sterile donor tomography could enable: (1) the harmonisation of donor and recipient tomography, which may minimise residual astigmatism for a particular donor-recipient pair; and (2) the improvement of IOL power calculation in a classical triple procedure by means of regression analysis between pre- and postoperative total refractive power of corneal grafts.


Author(s):  
Francesco Aiello ◽  
◽  
Federico Genzano Besso ◽  
Giulio Pocobelli ◽  
Gabriele Gallo Afflitto ◽  
...  

AbstractTo investigate the impact of Coronavirus Disease-2019 lockdown on the Italian Eye Bank organization. In this national retrospective, multicentric, cohort study, data from the Italian Eye Bank during both the lockdown and the first month after the lockdown period were retrieved. We compared the Italian Eye Bank metrics with the same timeframe of 2019 and 2018. Data from 13 out of 13 (100%) Italian Eye Banks were included in the analysis. A statistically significant reduction in the number of donor corneas retrieved in 2020 was found as compared to the same period in 2019 and in 2018, respectively (2020 = 1284; 2019 = 3088; 2018 = 3221; ANOVA: p < 0.0001). Only 534 corneas have been distributed by Eye Banks during the COVID-19-lockdown period (2020 = 534; 2019 = 1220; 2018 = 1237. ANOVA: p < 0.0001). Similarly, the number of wasted corneas due to postponed or cancelled surgeries was 421, resulting in a considerable increase as compared to the previous 2 years (2020 = 421; 2019 = 67; 2018 = 84; ANOVA: p = 0.0035). Overall, 45 donor corneas were rejected in accordance with the guidance of the Italian National Health Institute Italian National Transplant Centre (CNT). SARS-CoV-2 pandemic has profoundly affected every social and medical field, including the Eye Bank procurement and distribution programs. The current data collected from all the Italian Eye Banks highlights the present and the forthcoming difficulties that the Eye Bank community is going to experience, as for the ongoing pandemic.


2021 ◽  
pp. 112067212110143
Author(s):  
Luca Pagano ◽  
Kunal A Gadhvi ◽  
Giulia Coco ◽  
Matthew Fenech ◽  
Mitchell Titley ◽  
...  

Purpose: To compare the clinical outcomes of eye bank preloaded Descemet stripping automated endothelial keratoplasty (DSAEK) grafts and surgeon prepared. Methods: In this retrospective study, the data were obtained from two groups (a) surgeon cut DSAEK where tissue was prepared by the surgeon immediately before surgery, and (b) preloaded DSAEK tissue shipped to the surgeon after preparation by the eye bank. Standard DSAEK preparations using Moria microkeratome with single pass method were performed. For the tissues prepared by the eye banks, they were preloaded in an iGlide device and shipped in transport media. Standard DSAEK surgery using bimanual pull-through technique was performed for all the grafts. Air was used as a tamponade. Main outcome measures included best corrected visual acuity (BCVA) and rebubbling rate. Result: Out of 107 eyes of 101 patients that underwent DSAEK surgery, 33 tissues were prepared by the surgeon (sc-DSAEK), while 74 were prepared by the eye bank (pl-DSAEK). sc-DSAEK showed a rebubbling rate of 9.1%, compared to the 16.2% for the preloaded DSAEK ( p = 0.11). There was no statistical difference in postoperative BCVA between the two groups. Logistic regression analysis showed no association between detachment rate and cataract surgery, graft preparation method, graft diameter and reason for graft. Conclusion: Preloaded grafts have similar rebubbling rate and visual acuity achieved compared with surgeon prepared grafts.


Author(s):  
Jat Neha Singh

Background: The present study was conducted to study the donor profile and to assess the trends of cornea donation. Methodology: This was conducted as a hospital based cross sectional study at a tertiary care centre in Central India for a period of 5 years. Data was retrieved from 70 patients from eye bank who filled form of eye donation at Eye bank of our institution. Sociodemographic profile of donors, cause of death and time since death was recorded. Source of information regarding corneal donation and reason for not willing to donate the cornea for research purpose was recorded from the filled form. Further cornea enucleated were subjected to serology and their utilization for various purposes were recorded in questionnaire. Results: The present study retrieved data from a total of 70 donor forms with mean age of 65.84 ± 18.4 years. Cornea obtained from younger patients were mainly utilized for corneal transplantation whereas that from elderly age group > 60 years were mainly utilized for research/training purpose and the observed difference was statistically significant (p < 0.01). The corneas retrieved and utilized immediately after death were significantly used for optical or therapeutic purposes (p < 0.05). Conclusion: The present highlights the donor profile and trends of corneal donation at the tertiary care facility of Central India. It was observed that though the younger population and older population both are aware regarding corneal donation but still they are less aware on purpose for which cornea can be utilized. Quality of donor cornea is better when death to enucleation time interval was less.


Sign in / Sign up

Export Citation Format

Share Document