Scheimpflug Imaging of Corneas After Collagen Cross-Linking

Cornea ◽  
2009 ◽  
Vol 28 (5) ◽  
pp. 510-515 ◽  
Author(s):  
Tobias Koller ◽  
Hans Peter Iseli ◽  
Farhad Hafezi ◽  
Paolo Vinciguerra ◽  
Theo Seiler
2020 ◽  
Vol 40 (2) ◽  
pp. 141-147
Author(s):  
Ayşe ÇİÇEK ◽  
Mustafa ATAŞ ◽  
Mahmut Erkam ARSLAN ◽  
Hayrettin ÇOBANOĞLU ◽  
Esra VURAL ◽  
...  

Author(s):  
Adam Muzychuk ◽  
Victor Penner ◽  
Guillermo Rocha ◽  
Ahmed Al-Ghoul

ABSTRACT Purpose To utilize Scheimpflug imaging to describe corneal changes in keratoconic patients undergoing collagen cross- linking. Study type Case series. Study design Retrospective chart review at two sites: Calgary, Alberta and Brandon, Manitoba, Canada. All patients were diagnosed with keratoconus and had undergone corneal collagen crosslinking. All patients had pre- and post-procedure imaging done with Oculus Pentacam. Results Sixty-one eyes of 48 patients with 6 months follow- up and 36 eyes of 27 patients with one year follow-up were included. Average age was 27 ± 12 years (15-48 years). Fifty- one males and 10 females were studied. At 1 year follow-up, all Pentacam indices were found to improve: ISV −4.44 ± 18.6 (p = 0.16), IVA −0.07 ± 0.27 (p = 0.12), KI −0.009 ± 0.082 (p = 0.49), CKI −0.012 ± 0.027 (p = 0.01), IHA −3.87 ± 23.3 (p = 0.33) and IDH −0.062 ± 0.308 (p = 0.24). Keratometry measurements were flatter at the pupil centre by 0.87 ± 2.53 D (p = 0.05). Kmax and Kmin were flatter by 0.58 ± 1.37 D (p = 0.02) and 0.33 ± 1.70 D (p = 0.25) respectively. Pupil center pachymetry was thinner by 12.9 ± 21.1 µm (p = 0.0006) at 6 months, as were the corneal apex and thinnest local by 12.9 ± 22.3 µm (p = 0.001) and 21.8 ± 54.6 µm (p = 0.05) respectively. However, all central pachymetry readings were not statistically different from baseline at the one year measurements. Peripheral corneal measurements at 6 mm diameter were no different from baseline at 6 months, however, were significantly thicker at the 1 year follow-up. Conclusion The data, in this study, points to a more uniform cornea post corneal collagen crosslinking. The inferior cornea becomes flatter and superior cornea steeper with less variation when comparing the corneal curvatures. The peripheral cornea becomes thicker at 1 year post-procedure. Collagen cross- linking stabilizes the cornea. How to cite this article Penner V, Muzychuk A, Al-Ghoul A, Rocha G. The Effects of Epithelium-off Corneal Collagen Crosslinking on Peripheral Corneal Keratometry, Pachymetry as well as Scheimpflug Imaging Calculated Corneal Indices in Keratoconus. Int J Kerat Ect Cor Dis 2014;3(3):113-117.


Diabetes ◽  
1985 ◽  
Vol 34 (7) ◽  
pp. 703-705 ◽  
Author(s):  
J. R. Williamson ◽  
K. Chang ◽  
E. Rowold ◽  
J. Marvel ◽  
M. Tomlinson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document