Abstract
ObjectivePercutaneous transforaminal endoscopic discectomy (PTED) is minimally invasive and has been widely used to treat patients with lumbar disk herniation(LDH) due to its safety and efficiency. However, due to the unique anatomy of the L5-S1 level, the PTED procedure is often difficult to perform in the region. ZESSYS, a targeted and quantificational foraminoplasty device, may help to overcome these anatomical limitations. In this study, we assessed the efficiency and the short-term effects of PTED with ZESSY at the L5-S1 level.MethodsBetween January to August of 2018, Fifty-six patients with lumbar disk herniation at the single level of L5–S1 and underwent percutaneous transforaminal endoscopic discectomy were enrolled in this retrospective cohort study. They were segregated into the the TESSYS group and the ZESSYS group. The puncture time, foraminoplasty time, decompression time and fluoroscopy time evaluated for the operation efficiency. Clinical outcomes were assessed by visual analog scale(VAS) score and Oswestry Disability Index(ODI) score. The MacNab criteria were used to evaluate patient subjective satisfaction at 12-month follow-up postoperatively.ResultsThe average puncture time (5.29±2.05 minutes), foraminoplasty time (12.82±2.52 minutes) and fluoroscopy time (26.29±5.96 seconds) were all significantly shorter in the ZESSYS group than in the TESSYS group (average puncture time 8.07±3.13 minutes, p<0.01; foraminoplasty time, 17.18±2.92 minutes, p<0.01; fluoroscopy time, 34.73±6.86 seconds; p<0.01). No significant differences were observed between the 2 groups in the decompression time (p=0.057). The VAS score of low back pain and leg pain, as well as the ODI score, improved at all time points postoperatively compared with preoprative , in both the TESSYS group and the ZESSYS group (P < 0.05). There were no significant differences in the VAS score of low back pain, VAS score of leg pain, and ODI score between the TESSYS group and the ZESSYS group at the same time points (P > 0.05). According to the MacNab criteria, the excellent and good rate at 12-month follow-up postoperatively was 85.7% in the TESSYS group and 89.3% in the ZESSYS group (P > 0.05).ConclusionThe targeted and quantificational foraminoplasty device named ZESSYS was more efficient in the puncture and foraminoplasty procedures, effectively protecting the exiting nerve and minimizing the level of radiation exposure. The device is efficient and safe for PTED in treating lumbar disk herniation at the L5-S1 level.