scholarly journals SPECT-CT metabolic and morphological study of 2 types of cemented hip stem prostheses in primary total hip arthroplasty patients

Medicine ◽  
2021 ◽  
Vol 100 (52) ◽  
pp. e28299
Author(s):  
Daniel Rodríguez ◽  
Thiago Carnaval ◽  
Marcos del Carmen ◽  
Azahara Palomar-Muñoz ◽  
Montserrat Cortés-Romera ◽  
...  
1999 ◽  
Vol 14 (7) ◽  
pp. 832-839 ◽  
Author(s):  
Jonathan L. Knight ◽  
Timothy Coglon ◽  
Chad Hagen ◽  
John Clark

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Taku Ukai ◽  
Goro Ebihara ◽  
Masahiko Watanabe

Abstract Background This study aims to evaluate postoperative pain and functional and clinical outcomes of anterolateral supine (ALS) and posterolateral (PL) approaches for primary total hip arthroplasty. Materials and methods We retrospectively examined the joints of 110 patients who underwent primary total hip arthroplasty (THA). The ALS group was compared with the PL group using the pain visual analog scale (VAS) and narcotic consumption as pain outcomes. Functional outcomes included postoperative range of motion (ROM) of hip flexion, day on which patients could perform straight leg raising (SLR), day on which patients began using a walker or cane, duration of hospital stay, rate of transfer, and strength of hip muscles. Clinical outcomes included pre and postoperative Harris Hip Scores. Results No significant differences were found in the pain VAS scores or narcotic consumption between the two groups. The PL group could perform SLR earlier than the ALS group (P < 0.01). The ALS group started using a cane earlier (P < 0.01) and had a shorter hospital stay (P < 0.01) than the PL group. Degrees of active ROM of flexion at postoperative day (POD) 1 were significantly lower in the ALS group than in the PL group (P < 0.01). Regarding hip muscle strength, hip flexion was significantly weaker in the ALS group than in the PL group until 1-month POD (P < 0.01). External rotation from 2 weeks to 6 months postoperatively was significantly weaker in the PL group than in the ALS group (P < 0.01). Conclusion The ALS approach was more beneficial than the PL approach because ALS enabled better functional recovery of the strength of external rotation, improved rehabilitation, and involved a shorter hospital stay. Level of Evidence Level IV retrospective observational study.


2020 ◽  
pp. 112070002096964
Author(s):  
Kirill Gromov ◽  
Nanna H Sillesen ◽  
Thomas Kallemose ◽  
Henrik Husted ◽  
Henrik Malchau ◽  
...  

Background: Introduction of new implants should be monitored closely to capture any signs of compromising patient safety. Vitamin E infused highly-crosslinked polyethylene liners (VEPE) offer the potential for reduced wear. Highwall liners have been hypothesised to result in increased wear and potential liner fractures. The aim of this study was to determine the 3–7-year follow-up of highwall VEPE for primary total hip arthroplasty (THA), focusing on liner-related complications. Methods: We included 1221 consecutive THA operations from July 2010 to May 2014 with minimum follow-up of 3 (3.1–6.8) years Data collected included demographics, implant data, complications, reoperations, and deaths. Data were cross-referenced with the Danish Hip Arthroplasty Registry in order to ensure validity and completeness. Acetabular shell position was measured using Martell Hip Analysis Suite in a subgroup of 931 THAs. Results: Cumulative stem revision and shell revision at 3-year follow-up was 3.4% and 0.4% respectively. There were no revisions due to liner failure. Reason for revision included 11 dislocations, 15 soft-tissue revisions for infection, 44 stem revisions of which 34 were periprosthetic fractures and 13 shell revisions of which 6 were combined shell and stem revisions. Conclusion: Early follow-up of VEPE liners for primary THA have not shown any revisions associated with liner failure. Continued monitoring of new materials are necessary to capture any signs of compromised patient safety.


Sign in / Sign up

Export Citation Format

Share Document