Field Evaluation of Dried Blood Spots for HIV-1 Viral Load Monitoring in Adults and Children Receiving Antiretroviral Treatment in Kenya

2017 ◽  
Vol 74 (4) ◽  
pp. 399-406 ◽  
Author(s):  
Mary E. Schmitz ◽  
Simon Agolory ◽  
Muthoni Junghae ◽  
Laura N. Broyles ◽  
Muthusi Kimeu ◽  
...  
2009 ◽  
Vol 49 (6) ◽  
pp. 976-981 ◽  
Author(s):  
Asgeir Johannessen ◽  
Carolina Garrido ◽  
Natalia Zahonero ◽  
Leiv Sandvik ◽  
Ezra Naman ◽  
...  

2016 ◽  
Vol 237 ◽  
pp. 121-126 ◽  
Author(s):  
Emilande Guichet ◽  
Avelin Aghokeng ◽  
Sabrina Eymard-Duvernay ◽  
Nicole Vidal ◽  
Ahidjo Ayouba ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (4) ◽  
pp. e0124748 ◽  
Author(s):  
Sarah E. Rutstein ◽  
Mina C. Hosseinipour ◽  
Deborah Kamwendo ◽  
Alice Soko ◽  
Memory Mkandawire ◽  
...  

PLoS ONE ◽  
2020 ◽  
Vol 15 (4) ◽  
pp. e0230968
Author(s):  
Tuan Anh Nguyen ◽  
Tram Hong Tran ◽  
Binh Thanh Nguyen ◽  
Tram Thi Phuong Pham ◽  
Nhung Thi Hong Le ◽  
...  

2017 ◽  
Vol 55 (7) ◽  
pp. 2172-2179 ◽  
Author(s):  
A. Tariro Makadzange ◽  
F. Kathryn Boyd ◽  
Benjamin Chimukangara ◽  
Collen Masimirembwa ◽  
David Katzenstein ◽  
...  

ABSTRACT Although Roche COBAS Ampliprep/COBAS TaqMan (CAP/CTM) systems are widely used in sub-Saharan Africa for early infant diagnosis of HIV from dried blood spots (DBS), viral load monitoring with this system is not practical due to nonspecific extraction of both cell-free and cell-associated viral nucleic acids. A simplified DBS extraction technique for cell-free virus elution using phosphate-buffered saline (PBS) may provide an alternative analyte for lower-cost quantitative HIV virus load (VL) testing to monitor antiretroviral therapy (ART). We evaluated the CAP/CTM v2.0 assay in 272 paired plasma and DBS specimens using the cell-free virus elution method and determined the level of agreement, sensitivity, and specificity at thresholds of target not detected (TND), target below the limit of quantification (BLQ) (<20 copies/ml in plasma or <400 copies/ml in DBS), and VL of <1,000 copies/ml, and VL of <5,000 copies/ml. Reported plasma VL ranged from TND, or <20, to 5,781,592 copies/ml, and DBS VL ranged from TND, or <400, to 467,600 copies/ml. At <1000 copies/ml, agreement between DBS and plasma was 96.7% (kappa coefficient, 0.93; P < 0.0001). The mean difference between DBS and plasma VL values was −1.06 log 10 copies/ml (95% confidence interval [CI], −1.17, −0.97; P < 0.0001). At a treatment failure threshold of >1,000 copies/ml, the sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) were 92.7%, 100%, 100%, and 94.3%, respectively. PBS elution of DBS offers a sensitive and specific method for monitoring plasma viremia among adults and children on ART at the WHO-recommended threshold of >1,000 copies/ml on the Roche CAP/CTM system.


2002 ◽  
Vol 29 (3) ◽  
pp. 270-274
Author(s):  
Christine Laine ◽  
Daozhi Zhang ◽  
Walter W. Hauck ◽  
Barbara J. Turner

Sign in / Sign up

Export Citation Format

Share Document