Level-crossing absorption with narrow spectral width in Rb vapor with buffer gas

2010 ◽  
Vol 81 (2) ◽  
Author(s):  
Ye Jin Yu ◽  
Hyun Jun Lee ◽  
In-Ho Bae ◽  
Heung-Ryoul Noh ◽  
Han Seb Moon
Author(s):  
Michele Gozzelino ◽  
Salvatore Micalizio ◽  
Claudio E. Calosso ◽  
Aldo Godone ◽  
Filippo Levi
Keyword(s):  

2012 ◽  
Author(s):  
Mark Bashkansky ◽  
Fredrik K. Fatemi ◽  
Igor Vurgaftman
Keyword(s):  

2004 ◽  
Vol 69 (6) ◽  
Author(s):  
Eugeniy E. Mikhailov ◽  
Vladimir A. Sautenkov ◽  
Irina Novikova ◽  
George R. Welch
Keyword(s):  

2012 ◽  
Author(s):  
Mark Bashkansky ◽  
Fredrik K. Fatemi ◽  
Igor Vurgaftman
Keyword(s):  

2016 ◽  
Vol 41 ◽  
pp. 1660138 ◽  
Author(s):  
S. V. Ermak ◽  
V. V. Semenov ◽  
M. V. Petrenko ◽  
E. N. Pyatyshev

The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.


2013 ◽  
Vol 20 (4) ◽  
pp. 555-564 ◽  
Author(s):  
Wojciech Moćko

Abstract The paper presents the results of the analysis of the striker shape impact on the shape of the mechanical elastic wave generated in the Hopkinson bar. The influence of the tensometer amplifier bandwidth on the stress-strain characteristics obtained in this method was analyzed too. For the purposes of analyzing under the computing environment ABAQUS / Explicit the test bench model was created, and then the analysis of the process of dynamic deformation of the specimen with specific mechanical parameters was carried out. Based on those tests, it was found that the geometry of the end of the striker has an effect on the form of the loading wave and the spectral width of the signal of that wave. Reduction of the striker end diameter reduces unwanted oscillations, however, adversely affects the time of strain rate stabilization. It was determined for the assumed test bench configuration that a tensometric measurement system with a bandwidth equal to 50 kHz is sufficient


Sign in / Sign up

Export Citation Format

Share Document