Metrology and Measurement Systems
Latest Publications


TOTAL DOCUMENTS

279
(FIVE YEARS 0)

H-INDEX

20
(FIVE YEARS 0)

Published By De Gruyter Open Sp. Z O.O.

0860-8229, 0860-8229

2014 ◽  
Vol 21 (2) ◽  
pp. 293-304 ◽  
Author(s):  
Stanisław Trojanowski ◽  
Marian Ciszek ◽  
Eduard Maievskyi

Abstract One of the most important parameters, crucial to applications of superconductors in cryo-electrotechnique, is power loss. Measurements of losses in superconducting long sample wires require AC magnetic fields of a special geometry and appropriate high homogeneity. In the paper part of the theoretical basis for calculations and a simple design method for a race-track coil set are presented. An example of such home-made coils, with a magnetic field uniformity of about 0.2 % over the range of about 8 cm, is given. Also a simple electronic measurement system for the determination of AC magnetization loss in samples of superconducting tapes is presented.


2014 ◽  
Vol 21 (2) ◽  
pp. 247-256 ◽  
Author(s):  
Przemysław Podulka ◽  
Paweł Dobrzański ◽  
Paweł Pawlus ◽  
Agnieszka Lenart

Abstract In this paper distortion of surface topography measurement results by improper selection of the reference plane is taken into consideration. The following types of surfaces from cylindrical elements were analyzed: cylinder liners after plateau honing, cylinder liners with additionally burnished oil pockets and turned piston skirts. Surface topographies of these elements after a low wear process were also studied. In order to obtain areal surface topography parameters, the form was eliminated using cylinders and polynomials of the following degrees: 2, 3, 4, 6, 8, 10 and 12. Parameters of surfaces after form removal were compared. After analysis of results the reference elements for each kind of surface were recommended. A special procedure was proposed in order to select the degree of a polynomial. This method is based on surface topography changes with increase of polynomial degree. The effect of improper form elimination on measuring uncertainty was studied.


2014 ◽  
Vol 21 (2) ◽  
pp. 305-316 ◽  
Author(s):  
Sławomir Grzelak ◽  
Jarosław Czoków ◽  
Marcin Kowalski ◽  
Marek Zieliński

Abstract The ultrasonic flowmeter which is described in this paper, measures the transit of time of an ultrasonic pulse. This device consists of two ultrasonic transducers and a high resolution time interval measurement module. An ultrasonic transducer emits a characteristic wave packet (transmit mode). When the transducer is in receive mode, a characteristic wave packet is formed and it is connected to the time interval measurement module inputs. The time interval measurement module allows registration of transit time differences of a few pulses in the packet. In practice, during a single measuring cycle a few time-stamps are registered. Moreover, the measurement process is also synchronous and, by applying the statistics, the time interval measurement uncertainty improves even in a single measurement. In this article, besides a detailed discussion on the principle of operation of the ultrasonic flowmeter implemented in the FPGA structure, also the test results are presented and discussed


2014 ◽  
Vol 21 (2) ◽  
pp. 257-270 ◽  
Author(s):  
Ming Zhang ◽  
Kaicheng Li ◽  
Jun Wang ◽  
Shunfan He

Abstract Electronic voltage transformers (EVT) and electronic current transformers (ECT) are important instruments in a digital substation. For simple, rapid and convenient development, the paper proposed an on-site calibration system for electronic instrument transformers based on LabVIEW. In the system, analog signal sampling precision and dynamic range are guaranteed by the Agilent 3458A digital multimeter, and data synchronization is also achieved based on a self-developed PCI synchronization card. To improve the measurement accuracy, an error correction algorithm based on the Hanning window interpolation FFT has good suppression of frequency fluctuation and inter-harmonics interference. The human-computer interface and analysis algorithm are designed based on LabVIEW, and the adaptive communication technology is designed based on IEC61850 9-1/2. The calibration system can take into account pairs of digital output and analog output of the electronic voltage/current transformer calibration. The results of system tests show that the calibration system can meet the requirements of 0.2 class calibration accuracy, and the actual type test and on-site calibration also show that the system is easy to operate with convenience and satisfactory stability.


2014 ◽  
Vol 21 (2) ◽  
pp. 217-232 ◽  
Author(s):  
Andrzej Olencki ◽  
Piotr Mróz

Abstract Electric energy meters are designed to account energy under sinusoidal and nonsinusoidal conditions, because both, old and new standards for energy meters require testing their accuracy under different conditions. The latest EN 50470 standard increases the range of meter testing under nonsinusoidal conditions, introducing new shapes of test signals such as the phase fired waveform or the burst fired waveform. This paper discusses calibration problems of electronic revenue energy meters for direct connection and for connection through current transformers, and it proposes a new calibration procedure which reproduces normal operating conditions better: three-phase configurations of measurement systems, load range during meter testing or shapes of test signals. Recently, modern Electrical Power Standards, also known as Power Calibrators, enable automatic testing of various types of electrical devices, including electricity meters in their normal operating conditions. This article presents examples of single and multi position fully automatic test systems, which employ Power/Energy Calibrator from Poland as the precision source with programmed waveforms of three phase voltages up to 560 V and currents up to 120 A conforming to EN 50470, or with random waveforms generated by PC software random wave generator. Measurement uncertainty of the energy meters under different nonsinusoidal conditions using a test system with reference to accuracy of the power calibrator or to the reference meter, are discussed. Comparative analysis of test results for different shapes of voltage and current signals is presented in the conclusions of this paper.


2014 ◽  
Vol 21 (2) ◽  
pp. 363-376 ◽  
Author(s):  
Jarosław Sadowski

Abstract Velocity is one of the main navigation parameters of moving objects. However some systems of position estimation using radio wave measurements cannot provide velocity data due to limitation of their performance. In this paper a velocity measurement method for the DS-CDMA radio navigation system is proposed, which does not require full synchronization of reference stations carrier frequencies. The article presents basics of FDOA (frequency difference of arrival) velocity measurements together with application of this method to an experimental radio navigation system called AEGIR and with some suggestions about the possibility to implement such FDOA measurements in other kinds of asynchronous DS-CDMA radio networks. The main part of this paper present results of performance evaluation of the proposed method, based on laboratory measurements


2014 ◽  
Vol 21 (2) ◽  
pp. 233-246 ◽  
Author(s):  
Agustín Brau ◽  
Margarita Valenzuela ◽  
Jorge Santolaria ◽  
Juan José Aguilar

Abstract This paper presents a comparison of different techniques to capture nominal data for its use in later verification and kinematic parameter identification procedures for articulated arm coordinate measuring machines (AACMM). By using four different probing systems (passive spherical probe, active spherical probe, self-centering passive probe and self-centering active probe) the accuracy and repeatability of captured points has been evaluated by comparing these points to nominal points materialized by a ball-bar gauge distributed in several positions of the measurement volume. Then, by comparing these systems it is possible to characterize the influence of the force over the final results for each of the gauge and probing system configurations. The results with each of the systems studied show the advantages and original accuracy obtained by active probes, and thus their suitability in verification (active probes) and kinematic parameter identification (self-centering active probes) procedures.


2014 ◽  
Vol 21 (2) ◽  
pp. 281-292
Author(s):  
Qian Wang ◽  
Xiaomei Yang ◽  
Xiao Yan ◽  
Kaiyu Qin

Abstract Based on real-time multi-domain communication signal analysis architecture, a high-efficiency blind carrier frequency estimation algorithm using the power spectrum symmetry of the measured modulated signal is presented. The proposed algorithm, which utilizes the moving averaged power spectrum achieved by the realtime spectrum analysis, iteratively identifies the carrier frequency in according to the power difference between the upper sideband and lower sideband, which is defined and revised by the estimated carrier frequency in each iteration. When the power difference of the two sidebands converges to the preset threshold, the carrier frequency can be obtained. For the modulation analysis, the measured signal can be coarsely compensated by the estimated result, and the residual carrier frequency error is eliminated by a following carrier synchronization loop. Compared with previous works, owing to the moving averaged power spectrum normalization and the smart iterative step variation mechanism for the two sidebands definition, the carrier frequency estimation accuracy and speed can be significantly improved without increasing the computational effort. Experimental results are included to demonstrate the outstanding performance of the proposed algorithm.


2014 ◽  
Vol 21 (2) ◽  
pp. 351-362 ◽  
Author(s):  
Sergiusz Łuczak

Abstract The paper addresses the problem of experimental studies of miniature tilt sensors based on low-range accelerometers belonging to Microelectromechanical Systems (MEMS). A custom computer controlled test rig is proposed, whose kinematics allows an arbitrary tilt angle to be applied (i.e. its two components: pitch and roll over the full angular range). The related geometrical relationships are presented along with the respective uncertainties resulting from their application. Metrological features of the test rig are carefully evaluated and briefly discussed. Accuracy of the test rig is expressed in terms of the respective uncertainties, as recommended by ISO; its scope of application as well as the related limitations are indicated. Even though the test rig is mostly composed of standard devices, like rotation stages and incremental angle encoder, its performance can be compared with specialized certified machines that are very expensive. Exemplary results of experimental studies of MEMS accelerometers realized by means of the test rig are presented and briefly discussed. Few ways of improving performance of the test rig are proposed.


2014 ◽  
Vol 21 (2) ◽  
pp. 329-340 ◽  
Author(s):  
Pawel Baranowski ◽  
Krzysztof Damaziak ◽  
Jerzy Malachowski ◽  
Lukasz Mazurkiewicz ◽  
Henryk Polakowski ◽  
...  

Abstract This article presents the validation process of a brake FE model by means of temperature measured on a special stand using infrared technology. Unlike many other publications, the authors try to show the interaction between measurement technology and numerical modeling rather than only nice, perfectly correlated graphs. Some difficulties in choosing and using validation parameters are also pointed out and discussed. Finally, results of FE analyses are compared with measured data, followed by explanation of applied numerical technology and estimation of validation process effectiveness.


Sign in / Sign up

Export Citation Format

Share Document