High-resolution storage-ring measurements of the dissociative recombination ofH3+using a supersonic expansion ion source

2010 ◽  
Vol 82 (4) ◽  
Author(s):  
Holger Kreckel ◽  
Oldřich Novotný ◽  
Kyle N. Crabtree ◽  
Henrik Buhr ◽  
Annemieke Petrignani ◽  
...  
2011 ◽  
Vol 84 (2) ◽  
Author(s):  
F. O. Waffeu Tamo ◽  
H. Buhr ◽  
O. Motapon ◽  
S. Altevogt ◽  
V. M. Andrianarijaona ◽  
...  

2019 ◽  
Vol 25 (S2) ◽  
pp. 548-549
Author(s):  
Mikhail Dutka ◽  
Romaine Isaacs ◽  
Anna Prokhodtseva ◽  
Tomáš Vystavěl

1999 ◽  
Vol 110 (2) ◽  
pp. 890-901 ◽  
Author(s):  
A. Le Padellec ◽  
J. B. A. Mitchell ◽  
A. Al-Khalili ◽  
H. Danared ◽  
A. Källberg ◽  
...  

2018 ◽  
Vol 862 (2) ◽  
pp. 166 ◽  
Author(s):  
O. Novotný ◽  
H. Buhr ◽  
W. Geppert ◽  
M. Grieser ◽  
M. Hamberg ◽  
...  

1997 ◽  
Author(s):  
O. Heber ◽  
L. H. Andersen ◽  
D. Kella ◽  
H. B. Pedersen ◽  
L. Vejby-Christensen ◽  
...  

2011 ◽  
Vol 89 (1) ◽  
pp. 85-93 ◽  
Author(s):  
B. Botermann ◽  
C. Novotny ◽  
D. Bing ◽  
C. Geppert ◽  
G. Gwinner ◽  
...  

We present preparatory measurements for an improved test of time dilation at the experimental storage ring (ESR) at GSI in Darmstadt. A unique combination of particle accelerator experiments and laser spectroscopy is used to perform this test with the highest precision. 7Li+ ions are accelerated to 34% of the speed of light at the GSI Helmholtzzentrum für Schwerionenforschung and stored in the experimental storage ring. The forward and backward Doppler shifts of an electric dipole transition of these ions are measured with laser spectroscopy techniques. From these Doppler shifts, both the ion velocity β = ν/c and the time dilation factor [Formula: see text] can be derived for testing Special Relativity. Two laser systems have been developed to drive the 3S1→3P2 transition in 7Li+. Moreover, a detector system composed of photomultipliers, both to monitor the exact laser ion beam overlap as well as to optimize fluorescence detection, has been set up and tested. We investigate optical-optical double-resonance spectroscopy on a closed Λ-type three-level system to overcome Doppler broadening. A residual, broadened fluorescence background caused by velocity-changing processes in the ion beam is identified, and a background subtraction scheme implemented. At the present stage the experimental sensitivity, although already comparable with previous measurements on slower ion beams at the TSR storage ring that led to [Formula: see text] < 8.4 × 10–8, suffer from a poor signal-to-noise ratio. Modifications of the ion source as well as the detection system are discussed that promise to improve the sensitivity by one order of magnitude.


2002 ◽  
Vol 73 (3) ◽  
pp. 1284-1287 ◽  
Author(s):  
Jens Ulrik Andersen ◽  
Preben Hvelplund ◽  
Steen Brøndsted Nielsen ◽  
Shigeo Tomita ◽  
Helge Wahlgreen ◽  
...  

2016 ◽  
Vol 11 (08) ◽  
pp. P08004-P08004 ◽  
Author(s):  
S. Chaurasia ◽  
C. Kaur ◽  
V. Rastogi ◽  
A.K. Poswal ◽  
D.S. Munda ◽  
...  

2014 ◽  
Vol 20 (S3) ◽  
pp. 312-313
Author(s):  
S. Bauerdick ◽  
J. E. Sanabia ◽  
P. Mazarov ◽  
J. Fridmann ◽  
L. Bruchhaus ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document