scholarly journals Exceptional magnetic sensitivity of PT -symmetric cavity magnon polaritons

2019 ◽  
Vol 99 (21) ◽  
Author(s):  
Yunshan Cao ◽  
Peng Yan
Author(s):  
S.I. Woods ◽  
Nesco M. Lettsome ◽  
A.B. Cawthorne ◽  
L.A. Knauss ◽  
R.H. Koch

Abstract Two types of magnetic microscopes have been investigated for use in high resolution current mapping. The scanning fiber/SQUID microscope uses a SQUID sensor coupled to a nanoscale ferromagnetic probe, and the GMR microscope employs a nanoscale giant magnetoresistive sensor. Initial scans demonstrate that these microscopes can resolve current lines less than 10 µm apart with edge resolution of 1 µm. These types of microscopes are compared with the performance of a standard scanning SQUID microscope and with each other with respect to spatial resolution and magnetic sensitivity. Both microscopes show great promise for identifying current defects in die level devices.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2022
Author(s):  
Benjamin Spetzler ◽  
Elizaveta V. Golubeva ◽  
Ron-Marco Friedrich ◽  
Sebastian Zabel ◽  
Christine Kirchhof ◽  
...  

Magnetoelectric resonators have been studied for the detection of small amplitude and low frequency magnetic fields via the delta-E effect, mainly in fundamental bending or bulk resonance modes. Here, we present an experimental and theoretical investigation of magnetoelectric thin-film cantilevers that can be operated in bending modes (BMs) and torsion modes (TMs) as a magnetic field sensor. A magnetoelastic macrospin model is combined with an electromechanical finite element model and a general description of the delta-E effect of all stiffness tensor components Cij is derived. Simulations confirm quantitatively that the delta-E effect of the C66 component has the promising potential of significantly increasing the magnetic sensitivity and the maximum normalized frequency change ∆fr. However, the electrical excitation of TMs remains challenging and is found to significantly diminish the gain in sensitivity. Experiments reveal the dependency of the sensitivity and ∆fr of TMs on the mode number, which differs fundamentally from BMs and is well explained by our model. Because the contribution of C11 to the TMs increases with the mode number, the first-order TM yields the highest magnetic sensitivity. Overall, general insights are gained for the design of high-sensitivity delta-E effect sensors, as well as for frequency tunable devices based on the delta-E effect.


2021 ◽  
pp. 126903
Author(s):  
Ming-Song Ding ◽  
Xuan-Xuan Xin ◽  
Si-Yu Qin ◽  
Chong Li
Keyword(s):  

MRS Advances ◽  
2016 ◽  
Vol 1 (34) ◽  
pp. 2393-2399
Author(s):  
Sergey M. Karabanov ◽  
Dmitry V. Suvorov ◽  
Gennady P. Gololobov ◽  
Dmitry Y. Tarabrin ◽  
Evgeny V. Slivkin

ABSTRACTThe paper presents the research results of influence of various parameters of magnetic field concentrator geometry on sensitivity of magnetically controlled MEMS switches. It is shown that magnetic sensitivity increases with the growth of the magnetic concentrator width and practically does not depend on its length. It is established that dependence of magnetic sensitivity on the overlap length of the ferromagnetic flexible contact-concentrator has a minimum corresponding to 2-3 lengths of the contact gap. Recommendations on sensitivity increase of magnetically controlled MEMS switches are provided.


2002 ◽  
Vol 28 (10) ◽  
pp. 812-814
Author(s):  
S. I. Vorontsov ◽  
S. B. Baklanov ◽  
N. T. Gurin ◽  
S. G. Novikov
Keyword(s):  
X Ray ◽  

2013 ◽  
Vol 49 (3-4) ◽  
pp. 586-591 ◽  
Author(s):  
P. Kopċanský ◽  
N. Tomašoviċová ◽  
T. Tóth-Katona ◽  
N. Éber ◽  
M. Timko ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document