scholarly journals Origins of Incomplete Fusion Products and the Suppression of Complete Fusion in Reactions of Li7

2019 ◽  
Vol 122 (10) ◽  
Author(s):  
K. J. Cook ◽  
E. C. Simpson ◽  
L. T. Bezzina ◽  
M. Dasgupta ◽  
D. J. Hinde ◽  
...  
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Toshitaka Yoshii ◽  
Motonori Hashimoto ◽  
Satoru Egawa ◽  
Takashi Hirai ◽  
Hiroyuki Inose ◽  
...  

Abstract Background Autologous bone has been used for posterior lumbar intervertebral fusion (PLIF). However, harvesting autologous bone graft is associated with donor site complications. We previously developed a hydroxyapatite/collagen (HAp/Col) composite as an osteoconductive artificial bone, characterized by having a highly porous structure with sponge‐like elasticity. This study aims to investigate the effectiveness of HAp/Col composite with bone marrow aspirate (BMA) as a graft substitute in PLIF for the treatment of lumbar spinal diseases. Methods This study prospectively investigated patients who received one-level PLIF. For the interbody fusion, two titanium cages were inserted. On the one side of interbody space, HAp/Col composite incorporated with BMA filling the titanium cage was grafted. On the other side, local bone graft (LBG) harvested during decompressive laminotomy was grafted and then one-level instrumentation using pedicle screws was performed. The target levels were at L2/3 in 2 cases, L3/4 in 3 cases, L4/5 in 36 cases, and L5/S in 5 cases. We evaluated clinical symptoms and radiological outcomes of 46 patients and compared the fusion status of HAp/Col composite with that of LBG. Results The 1-year postoperative CT evaluation demonstrated that, in the HAp/Col, a complete fusion was observed in 38 patients (82.6%), whereas in the LBG, a complete fusion was observed in 35 patients (76.1%). There were no statistical differences between the HAp/Col and LBG. In the HAp/Col, incomplete fusion was observed in five patients (10.9%) and non-fusion in two patients (4.3%), and in the LBG, incomplete fusion was observed in nine patients (19.6%) and non-fusion in two patients (4.3%). At 2 years after the surgery, complete fusion increased to 44 patients (95.7%) in the HAp/Col and 41 patients (89.1%) in the LBG. There were no significant differences in the clinical scores for lumbar spine between patients with fusion and non-fusion. Conclusions The HAp/Col composite with BMA in the titanium cage can be effectively used as an alternative to conventional autologous LBG for intervertebral spinal fusion. Trial registration University hospital Medical Information Network, UMIN000045010, July 30th, 2021, Retrospectively registered, https://www.umin.ac.jp/english/.


Author(s):  
Harish Kumar ◽  
◽  
Rahbar Ali ◽  
D. Singh ◽  
M.P.N. Naseef ◽  
...  

2020 ◽  
Vol 29 (05) ◽  
pp. 2050029
Author(s):  
Manjeet Singh Gautam ◽  
Sukhvinder Duhan ◽  
Rishi Pal Chahal ◽  
Hitender Khatri ◽  
Suman B. Kuhar ◽  
...  

This work emphasized the role of the projectile breakup channel by studying the complete fusion (CF) and incomplete fusion (ICF) dynamics of [Formula: see text] reactions. The theoretical calculations for the chosen reactions have been done by opting for the coupled channel approach and the energy dependent Woods–Saxon potential (EDWSP) model. The below barrier fusion enhancements of the studied reactions are reasonably addressed by the outcomes of the adopted models, which in turn can be attributed to the couplings of nuclear structure degrees of freedom of the collision partners to their relative motion. In contrast, at above barrier energies, the CF cross-section data of the chosen reactions are found to be suppressed significantly when compared with the predictions made by using the present models. Interestingly, the fusion suppression factors of the given reactions can be minimized considerably with respect to the reported value when it is analyzed within the framework of the EDWSP model. For instance, in case of [Formula: see text] ([Formula: see text] reaction, the magnitude of fusion suppression factor is minimized up to 7% (13%) relative to the reported value whereas for [Formula: see text] ([Formula: see text] reaction, the fusion suppression factor is found to be less by 7% (8%) with reference to the reported value. Such suppression effects can be correlated with the low breakup threshold of alpha breakup channel associated with the loosely bound projectile. The projectiles being weakly bound systems split into two charged fragments and either of the breakup components is absorbed by the target resulting in the reduction of incoming flux going into fusion channel. The flux lost from the CF channel appears in the form of ICF yields. For [Formula: see text], total fusion (TF) cross-sections that are sum of CF and ICF cross-sections are also analyzed in conjunction with the EDWSP model and thus reasonably explained by the model calculations. In order to identify the ICF contribution, the ratio of ICF/TF cross-section data of [Formula: see text] reaction has been examined and thus properly addressed by using the EDWSP model. The presence of ICF component in TF cross-section clearly pointed out the breakup of projectile due to its loosely bound nature prior to the Coulomb barrier. Although ICF data of other systems are not available in the literature, a similar behavior is expected for ICF and TF data for [Formula: see text] and [Formula: see text] reactions.


2013 ◽  
Author(s):  
Sabir Ali ◽  
Kamal Kumar ◽  
Tauseef Ahmad ◽  
I. A. Rizvi ◽  
Avinash Agarwal ◽  
...  

2016 ◽  
Vol 31 (37) ◽  
pp. 1650201 ◽  
Author(s):  
Rajesh Kharab ◽  
Rajiv Chahal ◽  
Rajiv Kumar

We have analyzed the incomplete fusion (ICF), complete fusion (CF) and total fusion (TF) excitation functions for reactions induced by [Formula: see text] on [Formula: see text], [Formula: see text] and [Formula: see text] targets at near barrier energies using Wong’s formula in conjunction with the energy dependent Woods–Saxon potential. A phenomenological selection function is proposed to separate out the contribution of ICF and CF cross-sections in TF cross-section. The variation of relative contribution of ICF and CF in TF with respect to incident beam energy is very well reproduced through this approach.


2008 ◽  
Vol 77 (1) ◽  
Author(s):  
Pushpendra P. Singh ◽  
B. P. Singh ◽  
Manoj Kumar Sharma ◽  
Unnati ◽  
Devendra P. Singh ◽  
...  

2011 ◽  
Vol 47 (12) ◽  
Author(s):  
F. K. Amanuel ◽  
B. Zelalem ◽  
A. K. Chaubey ◽  
Avinash Agarwal ◽  
I. A. Rizvi ◽  
...  

2006 ◽  
Vol 15 (01) ◽  
pp. 237-245 ◽  
Author(s):  
S. MUKHERJEE ◽  
A. SHARMA ◽  
S. SODAYE ◽  
A. GOSWAMI ◽  
B. S. TOMAR

We measured the excitation functions for nine evaporation residues for the 12C + 115In system in the energy range well beyond the Coulomb barrier. The experimental results are compared with the theoretical values calculated using the Monte Carlo simulation code PACE2. Several complete and incomplete fusion products are observed in the present study. It is observed that a definite amount of incomplete fusion contribution is present, even at the lowest energy. The results clearly show the incomplete fusion contributions in the iodine and antimony products.


2021 ◽  
Vol 104 (2) ◽  
Author(s):  
F. Gollan ◽  
D. Abriola ◽  
A. Arazi ◽  
M. A. Cardona ◽  
E. de Barbará ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document