Designing the auxiliary power unit to occupy ram air turbine generator space

1974 ◽  
Vol 46 (3) ◽  
pp. 10-11
2020 ◽  
pp. 5-13
Author(s):  
Grigory Popov ◽  
◽  
Vasily Zubanov ◽  
Valeriy Matveev ◽  
Oleg Baturin ◽  
...  

The presented work provides a detailed description of the method developed by the authors for coordinating the working process of the main elements of the starting system for a modern gas turbine engine for a civil aviation aircraft: an auxiliary power unit (APU) and an air turbine – starter. This technique was developed in the course of solving the practical problem of selecting the existing APU and air turbine for a newly created engine. The need to develop this method is due to the lack of recommendations on the coordination of the elements of the starting system in the available literature. The method is based on combining the characteristics of the APU and the turbine, reduced to a single coordinate system. The intersection of the characteristic’s lines corresponding to the same conditions indicates the possibility of joint operation of the specified elements. The lack of intersection indicates the impossibility of joint functioning. The calculation also takes into account losses in the air supply lines to the turbine. The use of the developed method makes it possible to assess the possibility of joint operation of the APU and the air turbine in any operating mode. In addition to checking the possibility of functioning, as a result of the calculation, specific parameters of the working process at the operating point are determined, which are then used as initial data in calculating the elements of the starting system, for example, determining the parameters of the turbine, which in turn allow providing initial information for calculating the starting time or the possibility of functioning of the starting system GTE according to strength and other criteria. The algorithm for calculating the start-up time of the gas turbine engine was also developed by the authors and implemented in the form of an original computer program. Keywords: gas turbine engine start-up, GTE starting system, air turbine, methodology, joint work, auxiliary power unit, power, start-up time, characteristics matching, coordination, operational characteristics, computer program.


2009 ◽  
Vol 129 (2) ◽  
pp. 228-229
Author(s):  
Noboru Katayama ◽  
Hideyuki Kamiyama ◽  
Yusuke Kudo ◽  
Sumio Kogoshi ◽  
Takafumi Fukada

1989 ◽  
Author(s):  
DOUG MEYER ◽  
KENT WEBER ◽  
WALTER SCOTT

2020 ◽  
Vol 33 (2) ◽  
pp. 448-455 ◽  
Author(s):  
Liansheng LIU ◽  
Yu PENG ◽  
Lulu WANG ◽  
Yu DONG ◽  
Datong LIU ◽  
...  

2021 ◽  
Author(s):  
Thomas Bronson ◽  
Rudy Dudebout ◽  
Nagaraja Rudrapatna

Abstract The aircraft Auxiliary Power Unit (APU) is required to provide power to start the main engines, conditioned air and power when there are no facilities available and, most importantly, emergency power during flight operation. Given the primary purpose of providing backup power, APUs have historically been designed to be extremely reliable while minimizing weight and fabrication cost. Since APUs are operated at airports especially during taxi operations, the emissions from the APUs contribute to local air quality. There is clearly significant regulatory and public interest in reducing emissions from all sources at airports, including from APUs. As such, there is a need to develop technologies that reduce criteria pollutants, namely oxides of nitrogen (NOx), unburned hydrocarbons (UHC), carbon monoxide (CO) and smoke (SN) from aircraft APUs. Honeywell has developed a Low-Emissions (Low-E) combustion system technology for the 131-9 and HGT750 family of APUs to provide significant reduction in pollutants for narrow-body aircraft application. This article focuses on the combustor technology and processes that have been successfully utilized in this endeavor, with an emphasis on abating NOx. This paper describes the 131-9/HGT750 APU, the requirements and challenges for small gas turbine engines, and the selected strategy of Rich-Quench-Lean (RQL) combustion. Analytical and experimental results are presented for the current generation of APU combustion systems as well as the Low-E system. The implementation of RQL aerodynamics is well understood within the aero-gas turbine engine industry, but the application of RQL technology in a configuration with tangential liquid fuel injection which is also required to meet altitude ignition at 41,000 ft is the novelty of this development. The Low-E combustion system has demonstrated more than 25% reduction in NOx (dependent on the cycle of operation) vs. the conventional 131-9 combustion system while meeting significant margins in other criteria pollutants. In addition, the Low-E combustion system achieved these successes as a “drop-in” configuration within the existing envelope, and without significantly impacting combustor/turbine durability, combustor pressure drop, or lean stability.


2002 ◽  
Author(s):  
K. Keegan ◽  
M. Khaleel ◽  
L. Chick ◽  
K. Recknagle ◽  
S. Simner ◽  
...  

1965 ◽  
Vol 1 (1) ◽  
pp. 49-54
Author(s):  
David F. Berganni ◽  
Robert R. Barthelemy

Sign in / Sign up

Export Citation Format

Share Document