Current-limiting non-linear controller for single-phase AC/DC PWM power converters

Author(s):  
George C. Konstantopoulos ◽  
Qing-Chang Zhong
Author(s):  
Abdelhafid Ait Elmahjoub ◽  
Abdellah Ailane ◽  
Mustafa Rachik ◽  
El Houssine Labriji ◽  
Abdelmajid Abouloifa ◽  
...  

2019 ◽  
Vol 13 (2) ◽  
pp. 1813-1822 ◽  
Author(s):  
K. Arthishri ◽  
N. Kumaresan ◽  
N. Ammasai Gounden

2005 ◽  
Vol 125 (5) ◽  
pp. 537-543 ◽  
Author(s):  
Yoshinobu Asaoka ◽  
Akira Asakawa ◽  
Shigeru Yokoyama ◽  
Kazuo Nakada ◽  
Hitoshi Sugimoto

This study investigated current harmonic distortions emanating from domestic non-linear loads which have adverse deleterious effects on installed low voltage switchgears such as transformers and conductors. The study examined harmonic distortions emanating from dominant domestic nonlinear loads such as microwave, TV set, radio, fridge, video player and compacted fluorescence bulbs (CFLs) using a power quality equipment. From the results obtained, it was noted that there is need to mitigate harmonic distortions generated by domestic loads at point of common coupling (PCC). It is pertinent to mention that the recent study on supplied loads carried out in Kenya power grid shows that above 67% of power end users are domestic consumers. Under current last mile initiative and Global Partnership on Output Based Aid (GPOBA), unprecedented increase of domestic loads connected to the power grid is predicted. It is worth pointing out that most of these domestic loads have switch mode power supplies (SMPS) which have inherent characteristics of distorting current waveform which causes voltage distortions, over-heating of neutral conductors and premature failure of distribution transformers. Further, most of these loads have two modes; standby/sleep mode and operating mode. Results shows that the two modes generate current harmonic distortions which stream back to power utility network through the service cable. Recently, engineers have designed electronic devices that consume less power. These devices draw current in pulses rather than sinusoidal waveform. As a result, the quality of power supplies continues to deteriorate hence adversely affecting the installed low voltage switchgears such as distribution transformers. Although various mitigation measures exist to reduce the effects of harmonic distortions, this paper proposes a single phase active filter as an optimal solution for attenuating the harmonics emanating from domestic non-linear loads.


2021 ◽  
Vol 3 (397) ◽  
pp. 92-96
Author(s):  
G. Tsitsikyan ◽  
◽  
S. Kunaev ◽  

Object and purpose of research. The object of research is the rectifier (transducer) OPED-12,5-115 (О – single phase; P – direct current; Е – natural air cooling; D – on diodes with an example of document record; 12.5 – current rating; 115 – voltage rating). Materials and methods. Methods of power electronics and harmonic analysis are applied. Main results. Ways of appraisal and restriction for the harmonic coefficient (non-linear distortion coefficient from transducer) are worked out taking account of an active load of higher frequencies generator (400 Hz). Conclusion. Numerical estimations for the attenuation coefficient of harmonics 3, 5 and 7 are obtained using basic values Xd and Xq of generator АТО-20.


Sign in / Sign up

Export Citation Format

Share Document