Kinematic identification of a closed-chain manipulator using a laser interferometry based sensing technique

Author(s):  
G. Alici ◽  
B. Shirinzadeh
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Simone Chantal Gafner ◽  
Caroline Henrice Germaine Bastiaenen ◽  
Emmanuel Biver ◽  
Serge Ferrari ◽  
Lara Allet

Abstract Background Persons aged ≥ 65 years are currently the world’s fastest growing age group. An important complication of age is the increasing risk of falls. Falls have multifactorial etiology and modifiable risk factors open for interventions in prevention and rehabilitation, are of high interest. In this context, strong hip abductors seem to be important to prevent falls. A newly adapted measurement device to measure hip abductor strength (HAS) in a closed chain position was developed. We aim to assess feasibility, intra- and inter-tester reliability and construct and criterion validity of the new measure. Methods In two subsequent parts a feasibility, reliability and validity study with an adapted measurement instrument for the assessment of HAS (index test) in a closed chain position in persons aged ≥ 65 years will be conducted. Part I investigates feasibility of the measure in clinical settings as well as reliability of the new HAS test (n = 26). Part II evaluates construct and criterion validity (n = 169). Construct validity will be assessed cross-sectional, criterion validity by comparison with prospectively followed up fall history for 12 months (external criterion) and other functional fall risk assessments (Short Physical Performance Battery, Timed Up and Go test, usual gait speed and hand grip strength). Discussion Results of feasibility, will give insight in its applicability in daily clinical life and clinimetric properties will show if measurements of HAS in a closed chain position should be encouraged to include in fall risk assessments in older adults.


Langmuir ◽  
2021 ◽  
Author(s):  
Sirshendu Misra ◽  
Hideaki Teshima ◽  
Koji Takahashi ◽  
Sushanta K. Mitra

2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0011
Author(s):  
Tiago S. Baumfeld ◽  
Roberto Zambelli de A. Pinto ◽  
Fernando Araujo S. Lopes ◽  
Daniel Baumfeld ◽  
Camilo Tavares

Category: Hindfoot Introduction/Purpose: Objective: To evaluate and quantify the loss of ankle mobility in patients undergoing subtalar arthrodesis compared to the contralateral side, through physical examination. Methods: A total of 12 patients who had only the subtalar arthrodesis procedure from various causes in one foot were selected. The same foot and ankle surgeon performed all measurements of bilateral tibiotarsal range of motion, with loaded closed-chain and unloaded open-chain tests. Then, to assess whether there was a difference between the operated and the non-operated side, statistical analysis was performed with the Mann-Whitney test (Hollander and Wolfe 1999). Results: On the loaded closed-chain test, the operated side had a significantly lower range of motion than the contralateral side, with a mean difference of 5.4 degrees for dorsal flexion and 7.6 degrees for plantar flexion. The open-chain tests showed non- significant differences of 3 degrees for dorsal flexion and 5.3 degrees for plantar flexion. Conclusion: Subtalar joint arthrodesis was shown to cause a loss of mobility in the ipsilateral ankle, which is greater in plantar flexion movement.


2014 ◽  
Vol 21 (3) ◽  
pp. 105-114 ◽  
Author(s):  
Josep M. Porta ◽  
Lluis Ros ◽  
Oriol Bohigas ◽  
Montserrat Manubens ◽  
Carlos Rosales ◽  
...  

1989 ◽  
Vol 157 ◽  
Author(s):  
Young-Jin Jeon ◽  
M.F. Becker ◽  
R.M. Walser

ABSTRACTThis work was concerned with comparing the relative effects of boron and phosphorus impurities on the solid phase epitaxial (SPE) regrowth rate of self-ion amorphized layers in silicon wafers with (100) orientation. We used previously reported data measured by in situ, high precision, cw laser interferometry during isothermal annealing for temperatures from 450°C to 590°C, and concentrations in the range from 7.8×1018 cm-3 to 5×l020 cm-3 for boron (NB), and from 5×l017 cm-3 to 3×1020 cm-3 for phosphorus (Np) impurities. The basis for the comparison was a recently developed model that extends the Spaepen-Turnbull model for silicon recrystallization to include ionization enhanced processes.The experimental data for bom boron and phosphorus exhibited the linear variation in regrowth rate expected for low concentrations of implanted hydrogenic impurities having a concentration-independent fractional ionization in amorphous silicon. In the linear range the relative enhanced regrowth rate produced by these impurities can be expressed as a product of their, relative fractional ionizations, and the relative amount the rate constant for reconstruction is altered by localizing an electron, or a hole, at the reconstruction site. Assuming that a localized hole and electron equally softened the potential barrier for reconstruction, the experimental results indicated that boron had an ?40 meV lower barrier to ionization in amorphous silicon than phosphorus.The variations in the SPE regrowth rates with higher concentrations of both implanted boron and phosphorus were well fit by quadratic equations, but with different curvatures (+ and - for B and P respectively). This result was interpreted to indicate that SPE regrowth was further enhanced by localized hole pairs, but retarded by localized electron pairs.


Sign in / Sign up

Export Citation Format

Share Document