A travelling wave protection scheme for bipolar HVDC line

Author(s):  
Ying Zhang ◽  
Nengling Tai ◽  
Bin Xu
Energies ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2610
Author(s):  
Seung-Hyun Sohn ◽  
Gyu-Jung Cho ◽  
Chul-Hwan Kim

Recently, the operation of a mixed transmission system has increased due to rapid urbanization and the purpose of a good view. Therefore, a proper protection scheme for a mixed transmission system is required. Generally, when a fault occurs on a transmission line, auto reclosing is performed for the purpose of improving the continuity of service by clearing the fault and restoring the power system. However, the auto reclosing scheme should be applied to a mixed transmission system carefully because the mixed transmission system involves underground cable sections. When a fault occurs in the underground cable section, it is mostly a permanent fault. If auto reclosing is performed on a permanent fault condition, it may cause excessive overcurrent and switching surge, which can generate a serious impact on the whole transmission system and even cause an explosion. Due to this, many utilities worldwide do not allow auto reclosing or only apply it very restrictively on a mixed transmission system based on their practice. However, there is no clear guidance or standard related to auto reclosing on a mixed transmission system. Therefore, in this paper, an application of a recloser operation algorithm is proposed. Based on the proposed algorithm, reclosers can work properly and protect the transmission system. To verify the proposed algorithm, simulations were conducted using the ElectroMagnetic Transient Program (EMTP).


2012 ◽  
Vol 23 (8) ◽  
pp. 1304-1316 ◽  
Author(s):  
Zhang Ying ◽  
Tai Nengling ◽  
Xu Bin
Keyword(s):  

Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 2021 ◽  
Author(s):  
Lingtong Jiang ◽  
Qing Chen ◽  
Wudi Huang ◽  
Lei Wang ◽  
Yu Zeng ◽  
...  

This paper presents a novel pilot protection scheme of DC cable line in voltage-source-converter (VSC) based multi-terminal DC (MTDC) grids, which utilizes a novel phase-mode transformation to decouple the bipolar DC cable current into six mode and it uses the stationary wavelet transform to extract the modulus maxima of fault initial traveling waves current (FITWC). With accurate amplitude and polarities of the FITWC being collected from the fault-detection devices located at each terminal, the proposed scheme can correctly determine the faulty segment and the faulty pole. In this paper, the ratio of amplitudes between sixth mode forward and backward travelling wave currents is used to judge the faulty segment and the polarity of fifth mode forward travelling wave current is used to identify the faulty pole. A four-terminal VSC-based MTDC grid was built in PSCAD/EMTDC to evaluate the performance of the fault-protection scheme. Simulation results for different cases demonstrate that the proposed protection scheme is robust against noise, and has been tested successfully for fault resistance of up to 400 Ω. Since the scheme merely needs the characteristics of FITWCs, the practical difficulties of detecting subsequent travelling waves are avoided. Moreover, only the state signal is needed to send to the other side in proposed scheme, so low communication speed can satisfy the requirement of relay protection and it does not need the data synchronization seriously.


Sign in / Sign up

Export Citation Format

Share Document