Author(s):  
Rasha Ghilman Shahin ◽  
Hussein Diab Al-Majali

<p class="Abstract">The conventional three-phase alternating current (AC) to direct current (DC) converter can be modified using two isolated-gate bipolar transistor (IGBT) as by-pass switches connected to tapping points on the secondary side of the transformer. This scheme yields a reduction in both harmonic contents and reactive volt-ampere absorption. This modified converter possibly eliminates the need for an on-load tap-changer on the converter transformer. The modified AC/DC converter is fully analyzed and implemented under balanced conditions using MATLAB-Simulink. The expressions of the output DC voltage are derived for different cases. The supply current harmonic contents, the reactive power absorption and the power factor have been compared for three schemes; the conventional bridge, the modified bridge using one by-pass IGBT valve and the modified bridge with two by-pass IGBT valves. </p>


Author(s):  
Mengmeng Ai ◽  
Wenhui Liu ◽  
Yi Shan

In the process of Ultra high voltage direct current (UHVDC) transmission, the direct current (DC) bias of power transformer is easily induced, which makes the transformer exciting current distorted, the ferromagnetic material saturated and the magnetic leakage increased, and then leads to the increase of core vibration and noise. Aiming at this problem, taking a 240 MVA, 330 kV three-phase five-column power transformer as an example, the coupling of the electromagnetic field, structural force field and acoustic field is studied, and the influence of DC bias on vibration and noise of power transformer core is analyzed in this paper. According to the magnetic density and electric density of transformer core under different magnetic bias degree, the structural force field is solved, and the displacement and surface acceleration of core are obtained, which can be as the excitation of sound field to determine the noise distribution of transformer. In order to avoid the natural frequencies which easily cause resonance, the modal analysis is needed to obtain the natural frequencies and modal modes of the core. The transformer noise under no-load and DC bias conditions of the prototype is tested experimentally and compared with the theoretical calculation, the results prove the accuracy of the simulation calculation method in this paper.


Author(s):  
Anurekha Nayak ◽  
Manoj Kumar Maharana ◽  
Gayadhar Panda

Abstract This paper demonstrates the operational efficacy of a newly proposed fuzzy tuned fractional order controller to offer an improved frequency regulation of a multi area renewable energy source (RES) integrated nonlinear power system. The effect of governor dead band nonlinearity and generation rate constraint of hydro and thermal power plants are considered in the system. Moreover, a proposed appropriate High voltage direct current (HVDC) tie line model is incorporated in this work, to verify the frequency deviation. Different test cases are applied to verify the robustness of the controllers on frequency response. The superiority of the proposed controller upon Proportional integral and derivative (PID), fuzzy logic controller and fuzzy PID controller in minimizing frequency deviation has been verified through MATLAB SIMULINK environment.


2022 ◽  
Vol 28 (1) ◽  
pp. 52-64
Author(s):  
Truska Khalid Mohammed Salih ◽  
Zozan Saadallah Hussain ◽  
Firas Saaduldeen Ahmed

Nowadays power systems are huge networks that consist of electrical energy sources, static and lumped load components, connected over long distances by A.C. transmission lines. Voltage improvement is an important aspect of the power system. If the issue is not dealt with properly, may lead to voltage collapse.  In this paper, HVDC links/bipolar connections were inserted in a power system in order to improve the voltage profile. The load flow was simulated by Electrical Transient Analyzer Program (ETAP.16) program in which Newton- Raphson method is used. The load flow simulation studies show a significant enhancement of the power system performance after applying HVDC links on Kurdistan power systems. The bus voltages are significantly increased after connecting High Voltage Direct Current.


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 168
Author(s):  
Cathal W. O’Donnell ◽  
Mahdi Ebrahimi Salari ◽  
Daniel J. Toal

An investigation of the effects of wind gusts on the directly interconnected wind generators is reported, and techniques toward the mitigation of the wind gust negative influences have been proposed. Using a directly interconnected system approach, wind turbine generators are connected to a single synchronous bus or collection grid without the use of power converters on each turbine. This bus can then be transformed for transmission onshore using High Voltage Alternating Current, Low-Frequency Alternating Current or High Voltage Direct Current techniques with shared power conversion resources onshore connecting the farm to the grid. Analysis of the potential for instability in transient conditions on the wind farm, for example, caused by wind gusts is the subject of this paper. Gust magnitude and rise time/fall time are investigated. Using pitch control and the natural damping of the high inertial offshore system, satisfactory overall system performance and stability can be achieved during these periods of transience.


2021 ◽  
Author(s):  
Luis E. Martínez Santos ◽  
Roberto Linares y Miranda ◽  
Fermín P. Espino-Cortés

Historically, the Electromagnetic Compatibility (EMC) began with the disturbances at the radio navigation systems generated by the electrical power distribution lines; hence it was referred to as Radio Interference (RI). This disturbance is an Electromagnetic Interference (EMI). Although this type of EMI has been studied since the first decades of the past century, it still maintains a continued interest of the researchers, especially with the Corona Discharge (CD), generated by High Voltage Direct Current (HVDC) systems. Because of its design criterion and the concern that this phenomenon may affect the new radio communication systems in the very high frequency (VHF), ultra high frequency (UHF), and microwave bands, interest in their studies continues. In this chapter, an analysis of the electromagnetic spectrum of the CD is presented. The CD is generated at a short transmission line located within a semi-anechoic chamber. To be sure of the phenomenon, the CD is identified by its current pulse, which is well studied. The instruments used are an oscilloscope of 2 GHz and 2 GS/s, a spectrum analyzer, and an EMI test receiver. The results show that the CD concentrates its energy at frequencies below 70 MHz. In the UHF band, only narrowband signals very separated were found, with levels that cannot affect radio communication systems.


2021 ◽  
Author(s):  
Ruifeng Zhan ◽  
Yuying Hu ◽  
Fan Li ◽  
Zhou Mi ◽  
Lingpeng Dong

With the rapid development of China’s electric power industry, the high-voltage and long-distance direct current (DC) transmission effectively solved the problem of uneven power distribution. When the high voltage direct current transmission is in unipolar operation or bipolar asymmetric operation, part of the DC current will flow into the transformer winding through the grounded neutral point, which will cause the DC bias problem. This article used CDEGS software for modeling, and introduced the process of CDEGS software for DC bias simulation modeling. In this paper, the DC bias model of regional power grid is first established, based on the Zhejiang power grid topology and the test soil resistivity date. Then the DC bias currents of the transformers are calculated, and finally the corresponding treatment measures are proposed. According to the governance measures, this article adjusted the simulation model. The calculation results show that the treatment measures have good effects, which can provide an important reference for the future treatment of transformer DC bias.


Author(s):  
Mario A. Rios ◽  
Maria F. Perez

<p>Planning of high voltage direct current (HVDC) grids requires inclusion of reliability assessment of alternatives under study. This paper proposes a methodology to evaluate the adequacy of voltage source converter/VSC-HVDC networks. The methodology analyses the performance of the system using N-1 and N-2 contingencies in order to detect weaknesses in the DC network and evaluates two types of remedial actions to keep the entire system under the acceptable operating limits. The remedial actions are applied when a violation of these limits on the DC system occurs; those include topology changes in the network and adjustments of power settings of VSC converter stations. The CIGRE B4 DC grid test system is used for evaluating the reliability/adequacy performance by means of the proposed methodology in this paper. The proposed remedial actions are effective for all contingencies; then, numerical results are as expected. This work is useful for planning and operation of grids based on VSC-HVDC technology.</p>