Harmonic detection method based on positive sequence extractor of fundamental current

Author(s):  
Tao Chen ◽  
Lu Yang Wang ◽  
He Xing Wang ◽  
Shu Juan Yuan ◽  
Ning Gao ◽  
...  
2021 ◽  
Vol 248 ◽  
pp. 02045
Author(s):  
Yang Guoqing ◽  
Yan Kai ◽  
Wang Deyi ◽  
Chai Yuan ◽  
He Xu

The ip-iq harmonic detection method based on instantaneous reactive power has been widely used in active power filter (APF). However, the traditional ip-iq detection method has errors when the grid voltage is unbalanced and distorted. This paper proposes an improved ip-iq harmonic detection method, which uses adaptive notch filter (ANF) to extract the fundamental positive-sequence voltage signal, so that the phase locked loop (PLL) can still accurately obtain the phase information under bad grid conditions. At the same time, moving average filter (MAF) is used to replace low-pass filtering to reduce the detection delay. The simulation results show that the improved ip-iq detection method can accurately detect harmonic current under non-ideal grid voltage conditions, and has good dynamic characteristics.


2011 ◽  
Vol 58-60 ◽  
pp. 781-786
Author(s):  
Yan Dan Lin ◽  
Li Qing Tong ◽  
Yao Jie Sun

To improve the utilization of the inverter of the photovoltaic grid connected systems and decrease the harmonic of the grid, a novel selective harmonic detection method based on the synchronous rotator frame is proposed. Utilizing three-phase Park transform, the rotator vector is transferred to the static vector, and the synchronous harmonic is separated and acquired. The characteristic of negative and positive sequence harmonic is fleetly and exactly presented in all frequency domains. Additional, a new control strategy based on this harmonic detection is proposed for the integration photovoltaic grid connected generation and active power filter. Validity and practicality of the proposed selective harmonic detection method and control strategy are proved.


Author(s):  
Tiezhou Wu ◽  
An Wang ◽  
Yawen Xu

Abstract By using power electronic devices, photovoltaic grid-connected power generation may inject harmonics into the power system. As the photovoltaic grid-connected inverter has the same basic structure as the active power filter, so the unified control of the photovoltaic grid and active filtering can be achieved. When the current unified control system compensates harmonics of the grid side, it mainly uses ip-iq harmonic detection method, which is based on instantaneous reactive power theory. When the three-phase voltage is unbalanced, the method has a large voltage phase angle detection error and the signal of the low-pass filter tracking system is long, detection time delay and even failure occur. This paper proposes an improved fast harmonic detection method. When phase deviation or amplitude change occurs to the three-phase voltage, the positive and negative-sequence voltages are simultaneously park transformed. The negative-sequence component is filtered by the current average module to obtain the fundamental amount of the voltage, then the phase angle of the positive-sequence voltage is accurately calculated to improve the harmonic current detection accuracy. Through the study of the integral method, it is found that the least common multiple of each harmonic period can be used as the integral interval, and the integral value is also zero, so the detection delay time is reduced by replacing the low-pass filter with an integration module. The simulation results show that the proposed harmonic detection algorithm can accurately detect harmonics when the three-phase voltage is unbalanced, and about 0.057 s improve the harmonic detection speed compared with the commonly used ip-iq method.


Author(s):  
Hayato Yamauchi ◽  
Kosuke Uchida ◽  
Atsushi Yona ◽  
Tomonobu Senju

This paper proposes a phase detection method for harmonics and unbalanced voltage conditions. The proposed method uses harmonics and unbalanced voltage compensation circuit in addition to basic PLL (Phase Locked Loop) circuit. In the harmonic compensation circuit, the harmonic voltage component are eliminated from the input voltages using specific harmonic detection method. Besides, frequency information of power system used in the specific harmonic detection method is estimated by an extended complex Kalman filter. In the unbalanced voltage compensation circuit, the input voltage is normalized after the calculated positive sequence component. By means of the proposed method, excellent phase detection performance can be achieved under harmonics and unbalanced voltage conditions. Moreover, detection of positive sequence voltage component becomes possible under voltage drop conditions due to faults in power systems. The effectiveness of the proposed method is verified by simulation results.