Influence of Oil Quality on the Interpretation of Dissolved Gas Analysis Data

Author(s):  
Mohammed El Amine Senoussaoui ◽  
Issouf Fofana ◽  
Mostefa Brahami
Energetika ◽  
2019 ◽  
Vol 65 (1) ◽  
Author(s):  
Oleg Shutenko

The article presents results of oil-dissolved gas analysis for 239 units of high-voltage equipment with faults under which acetylene is the key gas. The analysis revealed 13 types of fault with acetylene as the key gas that are differentiated by values of the dissolved gas ratios, their concentrations, and fault nomographs. For each type of fault, graphic domains are plotted that, unlike the nomographs, allow taking into account a possible coordinate drift. A graphic domain based fault identification technique is introduced. The types of fault are briefly described, examples of their identification by different investigators given. Duval Triangle based comparative analysis of the equipment diagnosis data is performed. It is revealed that diagnoses made by different methods may differ significantly both from each other and from actual diagnoses. The results presented allow increasing fault identification accuracy via dissolved gas analysis data.


Sensors ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 4057 ◽  
Author(s):  
Sergio Bustamante ◽  
Mario Manana ◽  
Alberto Arroyo ◽  
Pablo Castro ◽  
Alberto Laso ◽  
...  

Power transformers are the most important assets of electric power substations. The reliability in the operation of electric power transmission and distribution is due to the correct operation and maintenance of power transformers. The parameters that are most used to assess the health status of power transformers are dissolved gas analysis (DGA), oil quality analysis (OQA) and content of furfuraldehydes (FFA) in oil. The parameter that currently allows for simple online monitoring in an energized transformer is the DGA. Although most of the DGA continues to be done in the laboratory, the trend is online DGA monitoring, since it allows for detection or diagnosis of the faults throughout the life of the power transformers. This study presents a review of the main DGA monitors, single- or multi-gas, their most important specifications, accuracy, repeatability and measurement range, the types of installation, valve or closed loop, and number of analogue inputs and outputs. This review shows the differences between the main existing DGA monitors and aims to help in the selection of the most suitable DGA monitoring approach according to the needs of each case.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2223 ◽  
Author(s):  
Sayed A. Ward ◽  
Adel El-Faraskoury ◽  
Mohamed Badawi ◽  
Shimaa A. Ibrahim ◽  
Karar Mahmoud ◽  
...  

Power transformers are considered important and expensive items in electrical power networks. In this regard, the early discovery of potential faults in transformers considering datasets collected from diverse sensors can guarantee the continuous operation of electrical systems. Indeed, the discontinuity of these transformers is expensive and can lead to excessive economic losses for the power utilities. Dissolved gas analysis (DGA), as well as partial discharge (PD) tests considering different intelligent sensors for the measurement process, are used as diagnostic techniques for detecting the oil insulation level. This paper includes two parts; the first part is about the integration among the diagnosis results of recognized dissolved gas analysis techniques, in this part, the proposed techniques are classified into four techniques. The integration between the different DGA techniques not only improves the oil fault condition monitoring but also overcomes the individual weakness, and this positive feature is proved by using 532 samples from the Egyptian Electricity Transmission Company (EETC). The second part overview the experimental setup for (66/11.86 kV–40 MVA) power transformer which exists in the Egyptian Electricity Transmission Company (EETC), the first section in this part analyzes the dissolved gases concentricity for many samples, and the second section illustrates the measurement of PD particularly in this case study. The results demonstrate that precise interpretation of oil transformers can be provided to system operators, thanks to the combination of the most appropriate techniques.