Dynamic Reactive Power Compensation in Multi-Infeed HVDC Power Grid Considering Transient Stability

Author(s):  
Zhen Peng ◽  
Shuqing Zhang ◽  
Yubo Sun ◽  
Jianbing Xu ◽  
Jingsen Zhou ◽  
...  
2013 ◽  
Vol 694-697 ◽  
pp. 846-849
Author(s):  
Jian Yuan Xu ◽  
Wei Fu Qi ◽  
Yun Teng

This paper mainly studies wind power fluctuations how to affect voltage stability after the wind power grid integration, and reactive power compensation equipment on improving effect. In certain parts of the wind farm, for example, firstly, analyzing the wind farm reactive power problems. Then introduce the reactive power compensation equipment that used in the wind farm. Finally, with PSCAD software, making a simulation analysis about the influence on the power grid voltage according to adopting the different reactive power compensation devices or not.


2014 ◽  
Vol 496-500 ◽  
pp. 1097-1100 ◽  
Author(s):  
Yin Sheng Wang ◽  
Xue Di Qiao

With the increase of power system load, the demand for reactive power is also increasing. In order to ensure the power quality and improve equipment utilization, transmission of reactive power in power grid can lead to network loss and the voltage of the electricity. Installing reactive power compensation device in power grid is the essential means to meet the demand of power grid reactive power [1].The parallel capacitor reactive power compensation device is equipped in the coal mine 3.3 kV system reactive power compensation [2]. Introducing the parallel capacitor reactive power compensation principle and related problems, analysis of the current commonly uses contactor, relay and thyristor switch device, chooses the contactor and breaks pipe parallel composite switch which can have contact and non-contact switch to solve their problems [3]. Using software EMTP simulation composite switch voltage zero input, the result is very good to restrain the impact flow; Compound switch off after current zero avoids the contactor breaking arc, the simulation thyristor compound switch and diode in parallel.


2013 ◽  
Vol 380-384 ◽  
pp. 3013-3017
Author(s):  
Xiao Ming Liu ◽  
Xin Sheng Niu ◽  
Jun Li Xiao ◽  
Jie Zhang

The AC system strength at DC receiving-end exerts great influences on the voltage stability of power grid. The selected DC control modes and reactive power compensation mode should fit with the AC system strength at receiving end. This paper analyzes the influences of AC system strength at DC receiving-end on voltage stability of power grid from the point of mechanism, and conducts simulations based on Shandong power grid.


2013 ◽  
Vol 805-806 ◽  
pp. 735-740
Author(s):  
Fan Tang ◽  
Li Jie Ding ◽  
Hua Zhang ◽  
Biao Wang

Heffron-Philips model including excitation reactive current compensation (RCC) is set up, impact analysis of RCC on the stability of power system is carried out by theoretical analysis and time domain simulation. Analysis results show that positive RCC increases damping torque while reduces synchronous torque; negative compensation increases synchronizing torque while reduces damping torque, and this phenomenon is more obvious in heavy load. Combined with the actual situation in Sichuan power grid, the role of negative RCC to increase transient stability and provide dynamic reactive power for emergency HVDC power support is analyzed, also negative RCC's influence on the damping characteristics in Sichuan power grid is evaluated.


2021 ◽  
Vol 57 (1) ◽  
pp. 64-79
Author(s):  
Jarosław Tępiński

Purpose: The purpose of the article is to present a reactive power compensation for small hydropower plants with an induction generator. The classic compensation with capacitors is discussed and its improvement is proposed. Instead of capacitors, a three level power electronic converter connected in parallel to the induction generator can be used to provide reactive power compensation. The purpose of the paper is to present the developed structure of an active compensator and its control method. The developed control method was verified on a laboratory stand. The project and the methods: As part of research, an active compensator was built as a three-level power electronic converter in topology with Neutral Point Clamped. Laboratory tests of a converter compensator were carried out on a stand equipped with an induction generator with a power of 7.5 kW. Laboratory system measurements were made using a power analyzer and an oscilloscope. Results: A control structure of an active compensator based on a voltage-oriented method was presented and discussed. The operation of the con- verter compensator has been verified on a laboratory stand equipped with a 7.5 kW induction generator. The compensator current reduces the reactive (inductive) component of the current consumed from a power grid to a value equal to zero. The reactive power compensator ensures that the tgφ power factor is maintained at a set value of zero, which corresponds to the total compensation of inductive reactive power consumed by an induction generator working in a hydropower plant. Operation of the active compensator did not cause a significant increase in the harmonic content in the current consumed from the power grid. Conclusions: The paper presents the issues regarding reactive power compensation in hydropower plants with induction generators. Commonly used capacitor compensation has been covered and as a result, it is proposed to replace it with power electronics converter compensation of reactive power connected in parallel induction generators. Active compensator provides compensation for the entire reactive power consumed by the induction generator. The use of the converter compensator of reactive power significantly contributes to the reduction of costs for reactive power incurred by the owners of hydropower plants. The reactive power compensator also has a positive impact on the operation of the entire power grid, power losses from the reactive component of the current on the impedances of power grid components are limited. Keywords: renewable source of electricity, reactive power, active compensator, induction generator Type of article: original scientific article


Sign in / Sign up

Export Citation Format

Share Document