Self-Adaptive Firefly Algorithm based transmission loss minimization using multi type FACTS devices

Author(s):  
R. Selvarasu ◽  
M. Surya Kalavathi
2013 ◽  
Vol 62 (4) ◽  
pp. 649-661 ◽  
Author(s):  
R. Selvarasu ◽  
M. Surya Kalavathi ◽  
C. Christober Asir Rajan

Abstract Static Var Compensator (SVC) is a popular FACTS device for providing reactive power support in power systems and its placement representing the location and size has significant influence on network loss, while keeping the voltage magnitudes within the acceptable range. This paper presents a Firefly algorithm based optimization strategy for placement of SVC in power systems with a view of minimizing the transmission loss besides keeping the voltage magnitude within the acceptable range. The method uses a self-adaptive scheme for tuning the parameters in the Firefly algorithm. The strategy is tested on three IEEE test systems and their results are presented to demonstrate its effectiveness.


Author(s):  
Sai Ram Inkollu ◽  
Venkata Reddy Kota

<p>Improvement of power system performance in terms of increased voltage profile and decreased transmission loss is becoming one of the challenging tasks to the system operators under open access environment. Apart from traditional power flow controlling devices, use of Flexible AC Transmission System (FACTS) devices can give an attractive solution for the operation and control of deregulated power system. The type, size, location and number of FACTS devices are to be optimized appropriately in order to get the targeted benefits. In this paper, two FACTS devices, Thyristor Controller Phase Shift Transformer (TCPST) and Interline Power Flow Controller (IPFC) are selected to obtain the required performance such as improvement of voltage profile and loss minimization. To search the optimal location and optimal rating of the selected FACTS devices, a hybrid algorithm which formulated with Particle Swarm Optimization (PSO) and Gravitational Search Algorithm (GSA) is proposed. At the first step, the optimization problem is solved for finding the optimal location of FACTS devices using PSO with an objective of voltage profile maximization and later GSA is implemented to optimize their parameters with an objective of transmission loss minimization. The proposed method is implemented on IEEE 30-bus test system and from the simulation results it can be proved that this technique is well suited for real-time application.  </p><p align="center"><strong><br /></strong></p>


2019 ◽  
Vol 14 (1) ◽  
pp. 5-11
Author(s):  
S. Rajasekaran ◽  
S. Muralidharan

Background: Increasing power demand forces the power systems to operate at their maximum operating conditions. This leads the power system into voltage instability and causes voltage collapse. To avoid this problem, FACTS devices have been used in power systems to increase system stability with much reduced economical ratings. To achieve this, the FACTS devices must be placed in exact location. This paper presents Firefly Algorithm (FA) based optimization method to locate these devices of exact rating and least cost in the transmission system. Methods: Thyristor Controlled Series Capacitor (TCSC) and Static Var Compensator (SVC) are the FACTS devices used in the proposed methodology to enhance the voltage stability of power systems. Considering two objectives of enhancing the voltage stability of the transmission system and minimizing the cost of the FACTS devices, the optimal ratings and cost were identified for the devices under consideration using Firefly algorithm as an optimization tool. Also, a model study had been done with four different cases such as normal case, line outage case, generator outage case and overloading case (140%) for IEEE 14,30,57 and 118 bus systems. Results: The optimal locations to install SVC and TCSC in IEEE 14, 30, 57 and 118 bus systems were evaluated with minimal L-indices and cost using the proposed Firefly algorithm. From the results, it could be inferred that the cost of installing TCSC in IEEE bus system is slightly higher than SVC.For showing the superiority of Firefly algorithm, the results were compared with the already published research finding where this problem was solved using Genetic algorithm and Particle Swarm Optimization. It was revealed that the proposed firefly algorithm gives better optimum solution in minimizing the L-index values for IEEE 30 Bus system. Conclusion: The optimal placement, rating and cost of installation of TCSC and SVC in standard IEEE bus systems which enhanced the voltage stability were evaluated in this work. The need of the FACTS devices was also tested during the abnormal cases such as line outage case, generator outage case and overloading case (140%) with the proposed Firefly algorithm. Outputs reveal that the recognized placement of SVC and TCSC reduces the probability of voltage collapse and cost of the devices in the transmission lines. The capability of Firefly algorithm was also ensured by comparing its results with the results of other algorithms.


2015 ◽  
Vol 785 ◽  
pp. 495-499
Author(s):  
Siti Amely Jumaat ◽  
Ismail Musirin

The paper presents a comparison of performance Static Var Compensator (SVC) and Thyristor Controlled Series Compensator (TCSC) with objective function to minimize the transmission loss, improve the voltage and monitoring the cost of installation. Simulation performed on standard IEEE 30-Bus RTS and indicated that EPSO a feasible to achieve the objective function.


Sign in / Sign up

Export Citation Format

Share Document