Efficient text localization in born-digital images by local contrast-based segmentation

Author(s):  
Kai Chen ◽  
Fei Yin ◽  
Amir Hussain ◽  
Cheng-Lin Liu
Author(s):  
Y. I. Golub ◽  
F. V. Starovoitov

The article study notion of the digital image contrast. Various quantitative estimates of the contrast of digital images are investigated. Comparative experimental studies of different contrast estimates were performed on two standard image databases. It is shown that the evaluation of contrast by calculating the arithmetic average or MSE values of a set of local estimates does not always coincide with the visual contrast assessment. Experimental results showed that the Weibull distribution shape parameter is a more accurate estimate of the set of local contrast estimates calculated by the BEGH, GORD, LOEN functions and correlates well with the visual contrast estimates.


2013 ◽  
Vol 59 (4) ◽  
pp. 343 ◽  
Author(s):  
Samabia Tehsin ◽  
Asif Masood ◽  
Sumaira Kausar ◽  
Younus Javed

Author(s):  
Jaap Brink ◽  
Wah Chiu

Crotoxin complex is the principal neurotoxin of the South American rattlesnake, Crotalus durissus terrificus and has a molecular weight of 24 kDa. The protein is a heterodimer with subunit A assigneda chaperone function. Subunit B carries the lethal activity, which is exerted on both sides ofthe neuro-muscular junction, and which is thought to involve binding to the acetylcholine receptor. Insight in crotoxin complex’ mode of action can be gained from a 3 Å resolution structure obtained by electron crystallography. This abstract communicates our progress in merging the electron diffraction amplitudes into a 3-dimensional (3D) intensity data set close to completion. Since the thickness of crotoxin complex crystals varies from one crystal to the other, we chose to collect tilt series of electron diffraction patterns after determining their thickness. Furthermore, by making use of the symmetry present in these tilt data, intensities collected only from similar crystals will be merged.Suitable crystals of glucose-embedded crotoxin complex were searched for in the defocussed diffraction mode with the goniometer tilted to 55° of higher in a JEOL4000 electron cryo-microscopc operated at 400 kV with the crystals kept at -120°C in a Gatan 626 cryo-holder. The crystal thickness was measured using the local contrast of the crystal relative to the supporting film from search-mode images acquired using a 1024 x 1024 slow-scan CCD camera (model 679, Gatan Inc.).


1998 ◽  
Vol 27 (2) ◽  
pp. 93-96 ◽  
Author(s):  
C H Versteeg ◽  
G C H Sanderink ◽  
S R Lobach ◽  
P F van der Stelt

1999 ◽  
Vol 28 (2) ◽  
pp. 123-126 ◽  
Author(s):  
E Gotfredsen ◽  
J Kragskov ◽  
A Wenzel
Keyword(s):  

Author(s):  
D. P. Gangwar ◽  
Anju Pathania

This work presents a robust analysis of digital images to detect the modifications/ morphing/ editing signs by using the image’s exif metadata, thumbnail, camera traces, image markers, Huffman codec and Markers, Compression signatures etc. properties. The details of the whole methodology and findings are described in the present work. The main advantage of the methodology is that the whole analysis has been done by using software/tools which are easily available in open sources.


Sign in / Sign up

Export Citation Format

Share Document