Thermal Analysis on IGBT Module Based Rotor Side Coverter of Doubly-fed Wind Turbine by Considering Inter-harmonic Current

Author(s):  
Yu Hu ◽  
Hui Li ◽  
Jing Liu ◽  
Xiangjie Xie ◽  
Tian Yang ◽  
...  
Energies ◽  
2015 ◽  
Vol 8 (5) ◽  
pp. 3386-3402 ◽  
Author(s):  
Yingning Qiu ◽  
Wenxiu Zhang ◽  
Mengnan Cao ◽  
Yanhui Feng ◽  
David Infield

2017 ◽  
Vol 10 (1) ◽  
pp. 56 ◽  
Author(s):  
Zakaria Sabiri ◽  
Nadia Machkour ◽  
Nabila Rabbah ◽  
Mohammed Nahid ◽  
Elm'kaddem Kheddioui

Author(s):  
Matheus Protasio de Lima ◽  
Marcos Vinício Oro ◽  
Matheus Schramm Dall'Asta ◽  
Telles Lazzarin ◽  
Edson Bazzo

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2287
Author(s):  
Kaina Qin ◽  
Shanshan Wang ◽  
Zhongjian Kang

With the rapid increase in the proportion of the installed wind power capacity in the total grid capacity, the state has put forward higher and higher requirements for wind power integration into the grid, among which the most difficult requirement is the zero-voltage ride through (ZVRT) capability of the wind turbine. When the voltage drops deeply, a series of transient processes, such as serious overvoltage, overcurrent, or speed rise, will occur in the motor, which will seriously endanger the safe operation of the wind turbine itself and its control system, and cause large-scale off-grid accident of wind generator. Therefore, it is of great significance to improve the uninterrupted operation ability of the wind turbine. Doubly fed induction generator (DFIG) can achieve the best wind energy tracking control in a wide range of wind speed and has the advantage of flexible power regulation. It is widely used at present, but it is sensitive to the grid voltage. In the current study, the DFIG is taken as the research object. The transient process of the DFIG during a fault is analyzed in detail. The mechanism of the rotor overcurrent and DC bus overvoltage of the DFIG during fault is studied. Additionally, the simulation model is built in DIgSILENT. The active crowbar hardware protection circuit is put into the rotor side of the wind turbine, and the extended state observer and terminal sliding mode control are added to the grid side converter control. Through the cooperative control technology, the rotor overcurrent and DC bus overvoltage can be suppressed to realize the zero-voltage ride-through of the doubly fed wind turbine, and ensure the safe and stable operation of the wind farm. Finally, the simulation results are presented to verify the theoretical analysis and the proposed control strategy.


Sign in / Sign up

Export Citation Format

Share Document