Paper title temperature-independent surrounding refractive index sensing using a single weakly tilted fiber Bragg grating

Author(s):  
Xiao Zhang ◽  
Wen Lin ◽  
Xiangping Li ◽  
Rensheng Shen ◽  
Guotong Du
2011 ◽  
Author(s):  
Bin-bin Luo ◽  
Ming-fu Zhao ◽  
Xiao-jun Zhou ◽  
De-yi Huang ◽  
Shao-fei Wang ◽  
...  

2011 ◽  
Vol 84-85 ◽  
pp. 582-585 ◽  
Author(s):  
Ming Fu Zhao ◽  
De Yi Huang ◽  
Bin Zhou ◽  
Lei Zi Jiao

In this paper, measurement method for the refractive index of chemical substances based on fiber Bragg grating (FBG) sensor was proposed. The relation between Bragg wavelength shift and surrounding refractive index (SRI) was analyzed theoretically and experimentally. The SRI sensitivity of the chemical sensor could be enhanced by reducing the cladding thickness of the FBG using hydrofluoric acid (HF) solution etching process. The experimental results indicated that the variation of Bragg wavelength increased as the SRI increased. In the low SRI region, the relationship between the Bragg wavelength shift and the change of the SRI was approximately linear.


Sensors ◽  
2019 ◽  
Vol 19 (23) ◽  
pp. 5211 ◽  
Author(s):  
Binbin Yan ◽  
Lei Sun ◽  
Yanhua Luo ◽  
Liwei Yang ◽  
Haifeng Qi ◽  
...  

In this paper, a temperature self-compensated refractive index sensor based on fiber Bragg grating (FBG) and the ellipsoid structure is demonstrated. The ellipsoid can excite the cladding modes and recouple them into the fiber core. Two well-defined wavelength bands are observed in the reflection spectrum of the proposed sensor, i.e., the Bragg resonant peak and the cladding resonant peaks. By measuring the wavelength shift of the cladding resonant peak, the surrounding refractive index (SRI) can be determined, and the wavelength shift of the Bragg resonant peak can be used as a reliable reference to self-compensate the temperature variation (temperature sensitivity of 10.76 pm/°C). When the SRI changes from 1.3352 to 1.3722, the cladding resonant peak redshifts linearly with an average sensitivity of 352.6 pm/RIU (refractive index unit). When the SRI changes from 1.3722 to 1.4426, an exponential redshift is observed with a maximum sensitivity of 4182.2 pm/RIU. Especially, the sensing performance is not very reliant on the distance between the FBG and the ellipsoid, greatly improving the ease of the fabrication.


2015 ◽  
Vol 23 (11) ◽  
pp. 14301 ◽  
Author(s):  
Carlo Edoardo Campanella ◽  
Francesco De Leonardis ◽  
Lorenzo Mastronardi ◽  
Pietro Malara ◽  
Gianluca Gagliardi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document