Understanding of Outdoor Insulator Characteristics through Leakage Current and Electrical Equivalent Circuit

Author(s):  
Suwarno
2021 ◽  
Vol 12 ◽  
pp. 19-23
Author(s):  
Mohamed B. El_Mashede ◽  
Magdy M. Zaky ◽  
A. A. Saleh ◽  
M. EL_Hanash

This paper introduces the Ozone generator parameters analysis and its engineering design aspects. Practically, Ozone is successfully used in water treatment applications; furthermore, it can be used to treat the secondary system cooling water in nuclear research reactors. The main element in this process is the Ozone generator; it has many parameters that need to be set at its design. These parameters can be divided into those related to the electrical equivalent circuit of corona dielectric barrier discharge (DBD), those associated with injected gas flow between the two electrodes, and those belonging to temperature of the electrodes. This paper is intended to those parameters that are related to the electrical equivalent circuit which has two standard models: linear and nonlinear. In this regard, the determination of the component values of nonlinear model can be achieved very hardly. To handle such determination, the nonlinear model can be approximately treated as a linear model in an approaching fashion. Based on this approximation, Lissajous plot and differential evolution (DE) methodologies are used for the computation of DBD ozone chamber parameters. Additionally, a new theoretical technique will be presented


Sign in / Sign up

Export Citation Format

Share Document