Material of the discharge channel walls and average radiation power low pressure nitrogen laser

Author(s):  
B. A. Kozlov ◽  
S. A. P'yanchenkov ◽  
V. I. Seredinov
2020 ◽  
Vol 24 (2) ◽  
pp. 22-27
Author(s):  
A.M. Gonopol'sky ◽  
S.G. Shashkovskiy ◽  
Y.A. Goldstein ◽  
S.G. Kireev ◽  
A.D. Volosatova ◽  
...  

Photochemical decomposition of phenol with a concentration of 5 to 24 mg/L using hydrogen peroxide and ultraviolet irradiation (UV/H2O2) was studied. Xenon flash lamp was chosen as a radiation source. It emits high-intensity continuous-spectrum radiation in a wide wavelength range from 200 to 1000 nm. The effect of the initial concentration of hydrogen peroxide and the source average radiation power on the phenol destruction rate were studied. An extremum in the dependence of the phenol decomposition rate constant on the initial concentration of hydrogen peroxide was found. Kinetic model of the process based on the obtained data was developed. It was tested by predicting phenol destruction rate with the different process parameters and gave good accuracy.


2000 ◽  
Vol 30 (12) ◽  
pp. 1107-1108 ◽  
Author(s):  
N F Andreev ◽  
O V Palashov ◽  
A K Potemkin ◽  
D H Reitze ◽  
Aleksandr M Sergeev ◽  
...  

1985 ◽  
Vol 5 (5) ◽  
pp. 291-295 ◽  
Author(s):  
M. Montaser Foad Sabry

An experimental study of the effect of screening the discharge channel on the output energy is presented. It has been found that a screened anode nitrogen laser generates higher output energy than that of a screened cathode, and also higher than that when both cathode and anode are unshielded at higher pressures.


2018 ◽  
Vol 7 (3.19) ◽  
pp. 92
Author(s):  
Sveshnikov V.K ◽  
Bazarkin A.F ◽  
Kurenschikov A.V

They consider the calculation technique for the resonance radiation power of a direct low-pressure sodium lamp with a sickle-shaped discharge tube cross-section. The calculation of the sodium discharge radiation power is difficult in such a tube, as compared with the calculation in a cylindrical shape tube. The dependence of the relative output of sodium discharge resonant radiation occurring in equivalent discharge tubes in the form of a parallelepiped and a cylinder is based on the involvement of the theory by M. Cayless. The obtained results were used to determine the power of DNaO-85M lamp resonant radiation. They presented the scheme of the device to study the influence of the tube geometry on sodium discharge power. It is shown that the power of the resonance radiation generated by an equivalent discharge will be the greater, the larger the cross section of the discharge tube. The discrepancy between the calculated and the experimental data for resonant radiation power determination in a crescent-shaped tube is less than 4%.  


2018 ◽  
Vol 61 (9) ◽  
pp. 926-931 ◽  
Author(s):  
M. L. Kozachenko ◽  
K. B. Savkin ◽  
N. P. Khatyrev

2011 ◽  
Vol 38 (4) ◽  
pp. 120-122 ◽  
Author(s):  
O. T. Loza ◽  
D. K. Ul’yanov ◽  
P. S. Strelkov ◽  
I. E. Ivanov ◽  
R. V. Baranov

Sign in / Sign up

Export Citation Format

Share Document