Virtual Vernier effect-based high sensitivity optical fiber humidity sensor

Author(s):  
Yaqi Tang ◽  
Chao Wang ◽  
Shuangchen Ruan ◽  
Chi Chiu Chan ◽  
Xinyong Dong
2021 ◽  
Vol 67 ◽  
pp. 102751
Author(s):  
Hang Su ◽  
Chunlong Zhao ◽  
Xiaokang Song ◽  
Fanxin Kong ◽  
Zhaorong Zhang ◽  
...  

2016 ◽  
Vol 233 ◽  
pp. 7-16 ◽  
Author(s):  
J. Ascorbe ◽  
J.M. Corres ◽  
I.R. Matias ◽  
F.J Arregui

2022 ◽  
Vol 68 ◽  
pp. 102767
Author(s):  
Yuan Wang ◽  
Chao Jiang ◽  
Xiaoshan Guo ◽  
Hailin Chen ◽  
Jiao Song ◽  
...  

2018 ◽  
Vol 45 ◽  
pp. 415-418 ◽  
Author(s):  
Lei Liang ◽  
Meili Li ◽  
Nan Liu ◽  
Hao Sun ◽  
Qiangzhou Rong ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 806
Author(s):  
Ning Wang ◽  
Wenhao Tian ◽  
Haosheng Zhang ◽  
Xiaodan Yu ◽  
Xiaolei Yin ◽  
...  

An easily fabricated Fabry-Perot optical fiber humidity sensor with high performance was presented by filling Graphene Quantum Dots (GQDs) into the Fabry-Perot resonator, which consists of two common single mode optical fibers. The relative humidity sensing performance was experimentally investigated by an interference spectrum drift between 11 %RH to 85 %RH. 0.567 nm/%RH sensitivity and 0.99917 linear correlation were found in experiments that showed high sensitivity, good and wide-range linear responding. Meanwhile, its good responding repeatability was demonstrated by two circle tests with increasing and decreasing relative humidity. For investigating the measurement influence caused by a temperature jitter, the temperature responding was experimentally investigated, which showed its linear responding with 0.033 nm/°C sensitivity. The results demonstrate the humidity sensitivity is greatly higher than the temperature sensitivity. The wavelength shift influence is 0.0198 nm with 0.6 °C max temperature jitter in the experiment, which can be ignored in humidity experiments. The fast-dynamic responses at typical humidity were demonstrated in experiments, with 5.5 s responding time and 8.5 s recovering time. The sensors with different cavity lengths were also investigated for their humidity response. All sensors gave good linear responding and high sensitivity. In addition, the relation curve between cavity length and response sensitivity also had good linearity. The combination of GQDs and single mode optical fibers showed easy fabrication and good performance for an optical fiber relative humidity sensor.


2021 ◽  
Vol 65 ◽  
pp. 102625
Author(s):  
Xulong Jia ◽  
Xuefang Zhou ◽  
Meihua Bi ◽  
Guowei Yang ◽  
Miao Hu ◽  
...  

2021 ◽  
Author(s):  
Jiachen Guo ◽  
Min Chang ◽  
Yinfeng Xiao ◽  
Qiuheng Song ◽  
Dong Zhao ◽  
...  

2021 ◽  
Vol 67 ◽  
pp. 102744
Author(s):  
Changgui Yu ◽  
Huaping Gong ◽  
Zhaoxu Zhang ◽  
Kai Ni ◽  
Chunliu Zhao

Sign in / Sign up

Export Citation Format

Share Document