A Fault Location Method for Local Control Distribution Network Based on Switch Status

Author(s):  
Guanbin Li ◽  
Qing Chen ◽  
Lingtong Jiang
2014 ◽  
Vol 971-973 ◽  
pp. 1463-1466
Author(s):  
Qian Wang ◽  
Wei Huang

In the distribution network fault location, the impact of information distortion needs to be to focus on, especially when the short-circuit current is used as the fault information. Considering the distortion or failure of real-time information and other issues, the quick location method of the failure point in distribution network is analyzed. Based on the mathematical model of distribution network fault location, firefly algorithm is applied. According to the characteristics of fault location objective function in distribution network, convergence criterion is proposed, which is suitable for fault location mathematical model.


2011 ◽  
Vol 105-107 ◽  
pp. 742-746
Author(s):  
Zhi Chao Huang ◽  
Yi Zhong ◽  
Cai Lin Li ◽  
Mu Liu ◽  
Sheng Zhen Yang

According to the generating process and propagation characteristics of earth-fault transient signal, an earth-fault location method for distribution network based on transient signal is presented. In the method, in order to change line characteristic impedance, a resonant filter circuit is paralleled in line segment border, so that it could cause transient current energy differences in feature frequency band on both sides of detection device. The location method achieves earth-fault area location through comparing transient current energy and energy attenuation coefficient in feature frequency band. The simulation test result shows that the method isn't influenced by distribution system grounded style, operation style and other factors and which could detect the earth-fault area rapidly and reliably in distribution network and has a high project application value.


2013 ◽  
Vol 8 (S1) ◽  
pp. S38-S46 ◽  
Author(s):  
Lilik Jamilatul Awalin ◽  
Hazlie Mokhlis ◽  
AbHalim Abu Bakar ◽  
Hasmaini Mohamad ◽  
Hazlee A. Illias

2021 ◽  
Vol 2121 (1) ◽  
pp. 012035
Author(s):  
Yalei Li ◽  
Xiaohong Zhang

Abstract In view of the large scale distributed power distribution network, distribution network from the traditional single main transformer power supply system becomes more complex broken power supply network, the trend of the distribution network flow and network frame produced change, failure fault feature information of great change, the traditional distribution network fault location method can not accurately obtain the location of the fault zone, the low accuracy of fault location, the error bigger problem a new fault location method of active distribution network combining graph theory and matrix was proposed. According to the knowledge of graph theory, the distribution network is simplified to topology diagram and described in the form of matrix, and then the fault judgment matrix is obtained through a series of matrix addition operation, and the type of fault interval can be identified accurately and quickly by combining the fault criterion table. The simulation results show that this method is simple in principle, fast and effective in criterion, suitable for the flexible operation mode of active distribution network structure, can accurately and quickly determine the fault segment, and can meet the requirements of complex distribution network fault location.