A Transient Power Quality Signal Denoising Method Based on CEEMDAN and UWT

Author(s):  
Pengyu LU ◽  
Hongxun Liu
2013 ◽  
Vol 655-657 ◽  
pp. 974-977
Author(s):  
Han Sheng Yang

In power quality monitoring system, there are unavoidably existing various kinds of noises in collected data,the presence of noise may result in increased false classification rate, denoising is an extremely important work for detection and classification of power quality disturbances. In order to improve the denoising result of power quality signal, an denoising method for power quality signal using Savitzky-Golay is proposed. Numerical results show that the proposed method can eliminate the influence of noise components and implement transient power quality disturbance detection and localization, thus providing good foundations for transient power quality disturbance monitoring under noise environment.


2014 ◽  
Vol 700 ◽  
pp. 99-102
Author(s):  
Meng Da Li ◽  
Yu Bo Duan ◽  
Yan Wang

This paper uses the method of S transformation to test the starting time, the end of the time, frequency and amplitude characteristics of common transient power quality signal disturbance. Through error analysis and simulation show that this method can accurately determine the disturbance occurred time and duration, and the identification and determination of disturbance can be simple and intuitive. It has the practical value and realistic significance to power quality signal interference analysis.


2012 ◽  
Vol 16 ◽  
pp. 1380-1385 ◽  
Author(s):  
Chen Chunling ◽  
Qi Huihui ◽  
Zheng Wei ◽  
Wu Pengfei

IRBM ◽  
2013 ◽  
Vol 34 (6) ◽  
pp. 362-370 ◽  
Author(s):  
M.K. Das ◽  
S. Ari

2020 ◽  
Vol 14 (10) ◽  
pp. 853-861
Author(s):  
Shanjun Li ◽  
Sashuang Sun ◽  
Qin Shu ◽  
Minwei Chen ◽  
Dakun Zhang ◽  
...  

2014 ◽  
Vol 602-605 ◽  
pp. 3177-3180
Author(s):  
Wei Ping Cui ◽  
Li Juan Du

In this paper, through comparison and analysis of various wavelet denoising methods, a new threshold function is constructed, and the selection of threshold is improved. Signal denoising simulation is made by the software MATLAB, the results show that the improved method is superior to the traditional method, and obtain a better denoising effect.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Chao Tan ◽  
Yanping Wang ◽  
Xin Zhou ◽  
Zhongbin Wang ◽  
Lin Zhang ◽  
...  

In order to solve the problem of industrial sensor signal denoising, an integrated denoising method for sensor mixed noises based on wavelet packet transform and energy-correlation analysis is proposed. The architecture of proposed method is designed and the key technologies, such as wavelet packet transformation, energy-correlation analysis, and processing method of wavelet packet coefficients based on energy-correlation analysis, are presented. Finally, a simulation example for a specific signal and an application of shearer cutting current signal, which mainly contain white Gaussian noise and impact noise, are carried out, and the simulation and application results show that the proposed method is effective and is outperforming others.


Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong ◽  
Zhengguang Liu

The overrun of transient power quality index caused by the large-capacity electric arc furnace (EAF) has become a prominent problem affecting the safe and stable operation of the power system. (1) In this paper, the relationship between arc furnace volt-age and current is derived based on the different stages of arc combustion, and the random variation of chaotic phenomenon of the arc voltage are simulated. Established an EAF model suitable for the study of transient power quality problems. (2) Take 50t AC EAF as an example to analyze the reactive power impact and the influence on the point of common coupling (PCC) voltage caused by the three-phase short circuit of the electrode. The results show that the experimental results are consistent with the theoretical analysis, verifying the correctness and effectiveness of the model. (3) When the three-phase short-circuit occurs, the reactive power impact is nearly 6 times that of normal operation, the short-circuit current is 2.66 times that of normal operation, and the effective value of the PCC voltage has dropped by 40.37%, which provides a theoretical basis for real-time compensation of impulsive reactive power and improvement of the transient power quality of the EAF.


Sign in / Sign up

Export Citation Format

Share Document