scholarly journals Research on Transient Power Quality of Large-capacity Electric Arc Furnace

Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong ◽  
Zhengguang Liu

The overrun of transient power quality index caused by the large-capacity electric arc furnace (EAF) has become a prominent problem affecting the safe and stable operation of the power system. (1) In this paper, the relationship between arc furnace volt-age and current is derived based on the different stages of arc combustion, and the random variation of chaotic phenomenon of the arc voltage are simulated. Established an EAF model suitable for the study of transient power quality problems. (2) Take 50t AC EAF as an example to analyze the reactive power impact and the influence on the point of common coupling (PCC) voltage caused by the three-phase short circuit of the electrode. The results show that the experimental results are consistent with the theoretical analysis, verifying the correctness and effectiveness of the model. (3) When the three-phase short-circuit occurs, the reactive power impact is nearly 6 times that of normal operation, the short-circuit current is 2.66 times that of normal operation, and the effective value of the PCC voltage has dropped by 40.37%, which provides a theoretical basis for real-time compensation of impulsive reactive power and improvement of the transient power quality of the EAF.

Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong

Three-phase AC electric arc furnace (EAF) is a typical non-linear load, causing many power quality problems. Most of the researches on the voltage problems of EAF mainly focus on the voltage fluctuation, and less on the transient voltage problems caused by EAF short circuit and open circuit. In this paper, the relationship between voltage and current of EAF is obtained by combining hyperbolic function and exponential function, then the white noise and chaotic circuit are added to establish the EAF model which is suitable for the study of voltage fluctuation and transient voltage. This paper analyzes the causes of the transient voltage problem of the EAF, calculates the short-circuit current, reactive impact and the influence on voltage at the point of common coupling (PCC) in the three-phase short-circuit of the EAF, and compares the calculation results with the simulation results to prove the accuracy of this model. The results show that the reactive impact of three-phase short circuit is about twice as much as that of normal operation of EAF, resulting in about 30% voltage sag at the PCC, which is very unfavorable to the power grid. This paper provides reference for transient power quality evaluation and dynamic reactive power compensation of EAF.


Author(s):  
Amarjeet Singh

The nonlinear and time varying nature of Electric Arc Furnace (EAF) causes power quality problems such as harmonics, flicker and voltage /current imbalances. In order to analyze the power quality of power system containing EAF, mathematical model of arc furnace becomes useful and informative. This paper presents different models of alternating current operated arc furnace to analyze the power quality in electric power system. The behavior of these models under static and dynamic conditions is studied. A comparison is also made between these models of arc furnace. Simulation results in MATLAB/ SIMULINK shows the voltage/current wave forms and percentage harmonic component in arc furnace system.


2021 ◽  
Vol 15 (1) ◽  
pp. 75-83
Author(s):  
Ngoc Toan Luong ◽  
◽  
Duc Tung Doan

Actual analysis showed that the arc furnace current contains many harmonics that adversely affect the power quality. There are many domestic and foreign reports on modeling and assessing the impact of EAF on the grid based on different models. However, EAF's selection of capacity for research and application of power quality improvement devices suitable to the power level has not been mentioned, these models are mainly built on Matlab Simulink software. should be primarily academic. PSCAD is one of the widely used software for electrical system simulation and is used by large companies such as ABB, Korean power corporation Kepco. Building EAF model with PSCAD software will increase the ability to apply simulation results into practice. The objective of the paper is to build an electric arc furnace model based on the energy conservation model with PSCAD software, thereby assessing the change of parameters in the model and the effect of this load on electricity grid during operation.


Author(s):  
L Ghiormez ◽  
M Panoiu ◽  
C Panoiu ◽  
I Muscalagiu

Sign in / Sign up

Export Citation Format

Share Document