Influence of Plate Width at Plate Heat Exchanger Evaporator Design for Organic Rankine Cycle with Heat Source Temperature of 70°C

Author(s):  
Nur Rohmah ◽  
Ghalya Pikra
2020 ◽  
Vol 24 (2 Part A) ◽  
pp. 831-842
Author(s):  
Chao Luo ◽  
Jun Zhao ◽  
Yongzhen Wang ◽  
Hongmei Yin ◽  
Qingsong An ◽  
...  

To match for the different temperature of the geothermal resource and strengthen the flexibility of organic Rankine cycle, a variable capacity power generation superstructure based on flash and organic Rankine cycle for geothermal energy was proposed. A combined flash-binary experimental prototype is newly established to investigate thermodynamic performance both on system and equipment in this paper. Pressured hot water is adopted as the extensive worldwide existed hydrothermal geothermal resource, eliminating the influence of the used heat transfer oil on evaporating process. The experimental results show that there is an optimal mass-flow rate of R245fa under the condition of different heat source temperature. Flash and binary power subsystem dominate the flash-binary power system, respectively, when the heat source temperature is 120? and 130?. The isotropic efficiency of modified compressor just between 0.2 and 0.25. The power output of per ton geofluid are 0.78 kWh/t and 1.31 kWh/t, respectively, when the heat source temperature are 120? and 130?. These results will predict the operation data of flash-binary power plant driven by the low-medium temperature geothermal water for construction in western of China.