source temperature
Recently Published Documents


TOTAL DOCUMENTS

178
(FIVE YEARS 41)

H-INDEX

20
(FIVE YEARS 3)

2022 ◽  
Vol 9 ◽  
Author(s):  
Yu-Jin Kim ◽  
Libing Yang ◽  
Evgueniy Entchev ◽  
Soolyeon Cho ◽  
Eun-Chul Kang ◽  
...  

In this paper, the development and demonstration of a hybrid solar geothermal heat pump polygeneration system is presented. The poly-generation system has been designed, modeled, and simulated in TRNSYS software environment. Its performance was assessed followed by installation and demonstration at a demo site in Cheongju, Korea. The space heating and cooling load of the building is 13.8 kW in heating mode at an ambient temperature of −10.3°C and 10.6 kW in cooling mode at an ambient temperature of 32.3°C. The simulation data were compared with the field demo data using ISO 13256. The results showed that the model data compare well with the demo data both in heating and cooling modes of operation. At a source temperature of 16.7°C, the heat pump lab performance data-based COPc shows 9.9, while demonstration COPc shows 10.3, thus, representing 4.3% relative error. The heat pump source temperature decreased by 4.0°C from 20.9°C to 16.9°C due to ground heat exchanger coupling and resulted in a COPc increase by 13.3% from 8.5 to 9.8. When compared at the design conditions (outside temperature of 32.3°C), the TRSNYS model overestimated the demonstration site data by 12%, 9.3 vs. 8.1 kW with power consumption of 3.1 vs. 2.2 kW. The hybrid polygeneration system power consumption decreased by 1.2 kW when ambient temperature decreased from 35°C to 25°C.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6648
Author(s):  
Young-Min Kim ◽  
Young-Duk Lee ◽  
Kook-Young Ahn

The supercritical carbon dioxide (S-CO2) power cycle is a promising development for waste heat recovery (WHR) due to its high efficiency despite its simplicity and compactness compared with a steam bottoming cycle. A simple recuperated S-CO2 power cycle cannot fully utilize the waste heat due to the trade-off between the heat recovery and thermal efficiency of the cycle. A split cycle in which the working fluid is preheated by the recuperator and the heat source separately can be used to maximize the power output from a given waste heat source. In this study, the operating conditions of split S-CO2 power cycles for waste heat recovery from a gas turbine and an engine were studied to accommodate the temperature variation of the heat sink and the waste heat source. The results show that it is vital to increase the low pressure of the cycle along with a corresponding increase in the cooling temperature to maintain the low-compression work near the critical point. The net power decreases by 6 to 9% for every 5 °C rise in the cooling temperature from 20 to 50 °C due to the decrease in heat recovery and thermal efficiency of the cycle. The effect of the heat-source temperature on the optimal low-pressure side was negligible, and the optimal high pressure of the cycle increased with an increase in the heat-source temperature. As the heat-source temperature increased in steps of 50 °C from 300 to 400 °C, the system efficiency increased by approximately 2% (absolute efficiency), and the net power significantly increased by 30 to 40%.


2021 ◽  
Author(s):  
Austin R. Baird ◽  
Walt Gill ◽  
Hector Mendoza ◽  
Victor Figueroa

Abstract Often in fire resistance testing of packaging vessels and other components, both the heat source temperature and the incident heat flux on a test specimen need to be measured and correlated. Standards such as ASTM E1529 require a specified temperature range from the heat source and a specified heatflux on the surface of the test specimen. There are other standards that have similar requirements. The geometry of the test environment and specimen may make heat flux measurements using traditional instruments (directional flame thermometers (DFTs) and water-cooled radiometers) difficult to implement. Orientation of the test specimen with respect to the thermal environment is also important to ensure that the heat flux on the surface of the test specimen is properly measured. Other important factors in the flux measurement include the thermal mass and surface emissivity of the test specimen. This paper describes the development of a cylindrical calorimeter using water-cooled wide-angle Schmidt-Bolter gauges to measure the incident heat flux for a vessel exposed to a radiant heat source. The calorimeter is designed to be modular to be modular with multiple configurations while meeting emissivity and thermal mass requirements via a variable thermal mass. The results of the incident heat flux and source temperature along with effective/apparent emissivity calculations are discussed.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3753
Author(s):  
Grzegorz Czerwiński ◽  
Jerzy Wołoszyn

Air cooling systems are currently the most popular and least expensive solutions to maintain a safe temperature in electronic devices. Heat sinks have been widely used in this area, allowing for an increase in the effective heat transfer surface area. The main objective of this study was to optimise the shape of the heat sink geometric model using the Adjoint Solver technique. The optimised shape in the context of minimal temperature value behind the heat sink is proposed. The effect of radiation and trapezoidal fin shape on the maximum temperature in the cooling system is also investigated. Simulation studies were performed in Ansys Fluent software using the Reynolds—averaged Navier–Stokes technique. As a result of the simulation, it turned out that not taking into account the radiation leads to an overestimation of temperatures in the system—even by 14 ∘C. It was found that as the angle and height of the fins increases, the temperature value behind the heat sink decreases and the heat source temperature increases. The best design in the context of minimal temperature value behind the heat sink from all analysed cases is obtained for heat sink with deformed fins according to iteration 14. The temperature reduction behind the heat sink by as much as 25 ∘C, with minor changes in heat source temperature, has been achieved.


2021 ◽  
Vol 10 (1) ◽  
pp. 135-152
Author(s):  
Jacques Hameury ◽  
Guillaume Failleau ◽  
Mariacarla Arduini ◽  
Jochen Manara ◽  
Elena Kononogova ◽  
...  

Abstract. The TIR100-2 emissometer (manufactured by Inglas GmbH & Co.KG) is an emissivity measurement device used by several producers of thermal insulation products for buildings and by some organizations certifying performance of insulation products. A comparison of emissivity measurements on low-emissivity foils involving different measurement techniques, including the TIR100-2 emissometer, gave widely dispersed results; the discrepancies were not explained. The metrological performance of the TIR100-2 emissometer and the uncertainties for measurement on reflective foils was not known, which could be detrimental to users. In order to quantify the performance of TIR100-2 devices for measurement of total near-normal emissivity of low-emissivity foils, the Laboratoire National de Métrologie et d'Essais (LNE) analyzed in detail the measuring principle and listed the associated assumptions and uncertainty sources. A TIR100-2 emissometer actually measures the reflectance and, for opaque materials, the emissivity is calculated from the measured reflectance. The parameters analyzed experimentally are the temperature stability and uniformity of the thermal radiation source, the emissivity of the radiation source, the response function linearity and the spectral sensitivity of the radiometric detection system measuring the reflected radiation, the size of the measurement area, and the measurement repeatability and reproducibility. A detailed uncertainty budget was established. The uncertainty sources taken into account are the uncertainties of the emissivities of the two calibrated standards used for calibration, the stability and uniformity of the radiation source temperature, the non-linearity and the spectral sensitivity of the radiometric detection system, the specific measurement condition related to the radiation source temperature, the uncertainties related to the temperatures of the standards and the sample, the noises on results, and the non-homogeneity in emissivity of the tested material. The combined measurement uncertainty was calculated for different types of reflective foils; the expanded uncertainty is around 0.03 for total near-normal emissivity measurements on smooth low-emissivity foils. A measurement campaign on five types of low-emissivity foils, involving four TIR100-2 emissometers, and a comparison to a primary reference setup at the Physikalisch-Technische Bundesanstalt (PTB) confirmed the uncertainties assessed.


2021 ◽  
Author(s):  
Aram Mohammed Ahmed ◽  
Attila R. Imre

AbstractThermodynamic efficiency is a crucial factor of a power cycle. Most of the studies indicated that efficiency increases with increasing heat source temperature, regardless of heat source type. Although this assumption generally is right, when the heat source temperature is close to the critical temperature, increasing the heat source temperature can decrease efficiency. Therefore, in some cases, the increase in the source temperature, like using improved or more collectors for a solar heat source can have a double negative effect by decreasing efficiency while increasing the installation costs. In this paper, a comparison of the CO2 subcritical cycle and the Trilateral Flash Cycle will be presented to show the potential negative effect of heat source temperature increase.


Materials ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1234
Author(s):  
Joel Joseph ◽  
Makoto Ohtsuka ◽  
Hiroyuki Miki ◽  
Manfred Kohl

This paper presents a lumped element model (LEM) to describe the coupled dynamic properties of thermomagnetic generators (TMGs) based on magnetic shape memory alloy (MSMA) films. The TMG generators make use of the concept of resonant self-actuation of a freely movable cantilever, caused by a large abrupt temperature-dependent change of magnetization and rapid heat transfer inherent to the MSMA films. The LEM is validated for the case of a Ni-Mn-Ga film with Curie temperature TC of 375 K. For a heat source temperature of 443 K, the maximum power generated is 3.1 µW corresponding to a power density with respect to the active material’s volume of 80 mW/cm3. Corresponding LEM simulations allow for a detailed study of the time-resolved temperature change of the MSMA film, the change of magnetic field at the position of the film and of the corresponding film magnetization. Resonant self-actuation is observed at 114 Hz, while rapid temperature changes of about 10 K occur within 1 ms during mechanical contact between heat source and Ni-Mn-Ga film. The LEM is used to estimate the effect of decreasing TC on the lower limit of heat source temperature in order to predict possible routes towards waste heat recovery near room temperature.


2021 ◽  
Vol 143 (9) ◽  
Author(s):  
Wahiba Yaïci ◽  
Evgueniy Entchev ◽  
Pouyan Talebizadehsardari ◽  
Michela Longo

Abstract Overall, there are numerous sustainable sources of renewable, low-temperature heat, principally solar energy, geothermal energy, and energy produced from industrial wastes. Extended utilization of these low-temperature alternatives has a certain capacity of decreasing fossil fuel use with its associated very hazardous greenhouse gas emissions. Researchers have commonly recognized the organic Rankine cycle (ORC) as a feasible and suitable system to produce electrical power from renewable sources based on its advantageous use of volatile organic fluids as working fluids (WFs). Researchers have similarly shown an affinity to the exploitation of zeotropic mixtures as ORC WFs due to their capability to enhance the thermodynamic performance of ORC systems, an achievement supported by improved fits of the temperature profiles of the WF and the heat source/sink. This paper determines both the technical feasibility and the benefits of using zeotropic mixtures as WFs by means of a simulation study of an ORC system. This study analyzes the thermodynamic performance of ORC systems using zeotropic WF mixtures to produce electricity driven by low-temperature solar heat sources for use in buildings. A thermodynamic model is created with an ORC system with and without a regenerator. Five zeotropic mixtures with diverse compositions between 0 and 1 in 0.2 increments of R245fa/propane, R245fa/hexane, R245fa/heptane, pentane/hexane, and isopentane/hexane are assessed and compared with identify the best blends of mixtures that are able to produce superior efficiency in their system cycles. Results disclosed that R245fa/propane (0.4/0.6) with regenerator produces the highest net power output of 7.9 kW and cycle efficiency of 9.4% at the operating condition with a hot source temperature of 85 °C. The study also investigates the effects of the volume flow ratio, and evaporation and condensation temperature glide on the ORC’s thermodynamic performance. Following a thorough analysis of each mixture, R245fa/propane is chosen for a parametric study to examine the effects of operating factors on the system’s efficiency and sustainability index. It was found that the highest cycle efficiency and highest second law cycle efficiency of around 10.5% and 84.0%, respectively, were attained with a mass composition of 0.6/0.4 at the hot source temperature of 95 °C and cold source temperature of 20 °C with a net power output of 9.6 kW. Moreover, results revealed that for zeotropic mixtures, there is an optimal composition range within which binary mixtures are tending to work more efficiently than the component pure fluids. In addition, a significant increase in cycle efficiency can be achieved with a regenerative ORC, with cycle efficiency in the range 3.1–9.8% versus 8.6–17.4% for ORC both without and with regeneration, respectively. In conclusion, utilizing zeotropic mixtures may well expand the restriction faced in choosing WFs for solar-powered ORC-based micro-combined heat and power (CHP) systems.


Sign in / Sign up

Export Citation Format

Share Document