An Impedance Model of a VSC-HVDC System Considering DC-side Dynamics for AC grid Stability Analysis

Author(s):  
Ni Liu ◽  
Hong Wang ◽  
Xiaoyong Zheng ◽  
Zhe Chen
Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3243
Author(s):  
Shaojian Song ◽  
Peichen Guan ◽  
Bin Liu ◽  
Yimin Lu ◽  
HuiHwang Goh

Impedance-based stability analysis is an effective method for addressing a new type of SSO accidents that have occurred in recent years, especially those caused by the control interaction between a DFIG and the power grid. However, the existing impedance modeling of DFIGs is mostly focused on a single converter, such as the GSC or RSC, and the influence between the RSC and GSC, as well as the frequency coupling effect inside the converter are usually overlooked, reducing the accuracy of DFIG stability analysis. Hence, the entire impedance is proposed in this paper for the DFIG-based WECS, taking coupling factors into account (e.g., DC bus voltage dynamics, asymmetric current regulation in the dq frame, and PLL). Numerical calculations and HIL simulations on RT-Lab were used to validate the proposed model. The results indicate that the entire impedance model with frequency coupling is more accurate, and it is capable of accurately predicting the system’s possible resonance points.


2015 ◽  
Vol 30 (3) ◽  
pp. 1221-1230 ◽  
Author(s):  
Ling Xu ◽  
Lingling Fan ◽  
Zhixin Miao

Energies ◽  
2019 ◽  
Vol 12 (11) ◽  
pp. 2035 ◽  
Author(s):  
Liang Chen ◽  
Heng Nian ◽  
Yunyang Xu

The sequence domain impedance modeling of wind turbines (WTs) has been widely used in the stability analysis between WTs and weak grids with high line impedance. An aggregated impedance model of the wind farm is required in the system-level analysis. However, directly aggregating WT small-signal impedance models will lead to an inaccurate aggregated impedance model due to the mismatch of reference frame definitions among different WT subsystems, which may lead to inaccuracy in the stability analysis. In this paper, we analyze the impacts of the reference frame mismatch between a local small-signal impedance model and a global one on the accuracy of aggregated impedance and the accuracy of impedance-based stability analysis. The results revealed that the impact is related to the power distribution of the studied network. It was found that that the influence of mismatch on stability analysis became subtle when subsystems were balanced loaded. Considering that balanced loading is a common configuration of the practical application, direct impedance aggregation by local small-signal models can be applied due to its acceptable accuracy.


Sign in / Sign up

Export Citation Format

Share Document