A High-Resolution Anisotropic Finite-Volume Head Model for EEG Source Analysis

Author(s):  
Michael J. D. Cook ◽  
Zoltan J. Koles
2009 ◽  
Vol 30 (9) ◽  
pp. 2862-2878 ◽  
Author(s):  
Seok Lew ◽  
Carsten H. Wolters ◽  
Alfred Anwander ◽  
Scott Makeig ◽  
Rob S. MacLeod

NeuroImage ◽  
2013 ◽  
Vol 76 ◽  
pp. 282-293 ◽  
Author(s):  
Seok Lew ◽  
Danielle D. Sliva ◽  
Myong-sun Choe ◽  
P. Ellen Grant ◽  
Yoshio Okada ◽  
...  

NeuroImage ◽  
2009 ◽  
Vol 44 (2) ◽  
pp. 399-410 ◽  
Author(s):  
M RULLMANN ◽  
A ANWANDER ◽  
M DANNHAUER ◽  
S WARFIELD ◽  
F DUFFY ◽  
...  

Author(s):  
Sergey N. Makarov ◽  
William A. Wartman ◽  
Mohammad Daneshzand ◽  
Kyoko Fujimoto ◽  
Tommi Raij ◽  
...  

AbstractBackgroundTranscranial magnetic stimulation (TMS) is currently the only non-invasive neurostimulation modality that enables painless and safe supra-threshold stimulation by employing electromagnetic induction to efficiently penetrate the skull. Accurate, fast, and high resolution modeling of the electric fields (E-fields) may significantly improve individualized targeting and dosing of TMS and therefore enhance the efficiency of existing clinical protocols as well as help establish new application domains.ObjectiveTo present and disseminate our TMS modeling software toolkit, including several new algorithmic developments, and to apply this software to realistic TMS modeling scenarios given a high-resolution model of the human head including cortical geometry and an accurate coil model.MethodThe recently developed charge-based boundary element fast multipole method (BEM-FMM) is employed as an alternative to the 1st order finite element method (FEM) most commonly used today. The BEM-FMM approach provides high accuracy and unconstrained field resolution close to and across cortical interfaces. Here, the previously proposed BEM-FMM algorithm has been improved in several novel ways.Results and ConclusionsThe improvements resulted in a threefold increase in computational speed while maintaining the same solution accuracy. The computational code based on the MATLAB® platform is made available to all interested researchers, along with a coil model repository and examples to create custom coils, head model repository, and supporting documentation. The presented software toolkit may be useful for post-hoc analyses of navigated TMS data using high-resolution subject-specific head models as well as accurate and fast modeling for the purposes of TMS coil/hardware development.


Author(s):  
Sergey N. Makarov ◽  
Jyrki Ahveninen ◽  
Matti Hämäläinen ◽  
Yoshio Okada ◽  
Gregory M. Noetscher ◽  
...  

AbstractIn this study, the boundary element fast multipole method or BEM-FMM is applied to model compact clusters of tightly spaced pyramidal neocortical neurons firing simultaneously and coupled with a high-resolution macroscopic head model. The algorithm is capable of processing a very large number of surface-based unknowns along with a virtually unlimited number of elementary microscopic current dipole sources distributed within the neuronal arbor.The realistic cluster size may be as large as 10,000 individual neurons, while the overall computation times do not exceed several minutes on a standard server. Using this approach, we attempt to establish how well the conventional lumped-dipole model used in electroencephalography/magnetoencephalography (EEG/MEG) analysis approximates a compact cluster of realistic neurons situated either in a gyrus (EEG response dominance) or in a sulcus (MEG response dominance).


2019 ◽  
Author(s):  
Maria L Bringas Vega ◽  
Shengnan Liu ◽  
Min Zhang ◽  
Ivonne Pedroso Ibañez ◽  
Lilia M. Morales Chacon ◽  
...  

AbstractWe used EEG source analysis to identify which cortical areas were involved in the automatic and controlled processes of inhibitory control on a flanker task and compared the potential efficacy of recombinant-human erythropoietin (rHuEPO) on the performance of Parkinson’ s Disease patients.The samples were 18 medicated PD patients (nine of them received rHuEPO in addition to their usual anti-PD medication through random allocation and the other nine patients were on their regular anti-PD medication only) and 9 age and education-matched healthy controls (HCs) who completed the flanker task with simultaneous EEG recordings. N1 and N2 event-related potential (ERP) components were identified and a low-resolution tomography (LORETA) inverse solution was employed to localize the neural generators.Reaction times and errors were increased for the incongruent flankers for PD patients compared to controls. EEG source analysis identified an effect of rHuEPO on the lingual gyri for the early N1 component. N2-related sources in middle cingulate and precuneus were associated with the inhibition of automatic responses evoked by incongruent stimuli differentiated PD and HCs.From our results rHuEPO, seems to mediate an effect on N1 sources in lingual gyri but not on behavioural performance. N2-related sources in middle cingulate and precuneus evoked by incongruent stimuli differentiated PD and HCs.


Sign in / Sign up

Export Citation Format

Share Document