DC-Link Voltage Ripple Cancellation Strategies for Three-Phase Four-Wire PV Inverters Under Unbalanced Grid Voltages

Author(s):  
Cheng-Yu Tang ◽  
Ching-Ju Cheng
Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 651
Author(s):  
Songda Wang ◽  
Danyang Bao ◽  
Gustavo Gontijo ◽  
Sanjay Chaudhary ◽  
Remus Teodorescu

A modular multilevel converter’s (MMC’s) submodule (SM)-capacitor voltage will increase under unbalanced grid conditions. Depending on the imbalance level, the voltage ripple can be considerably high, and it can exceed the pre-defined safe limits. If this occurs, the converter will trip, which can lead to serious stability problems for the grid. This paper first proposes an analytical solution for deriving the three-phase imbalanced SM ripple of an MMC under an unbalanced grid. With this analytical tool, the imbalance mechanism of the SM voltage ripple can be easily understood. What is more, the symmetrical component method is first applied to analyze the three-phase SM capacitor ripple, and the positive-/negative-/zero-sequence components of the three-phase SM voltage ripple are easily identified by the proposed analytical method. Then, based on this powerful analytical tool, the proper circulating-current profile to be injected can be obtained, allowing for the right compensation of the voltage ripple. Based on this approach, two new voltage ripple compensation methods are proposed in this paper. Simulations were carried out to validate the analytical description of the submodule-capacitor voltage ripple proposed in this paper. Moreover, simulation and experimental results are provided to validate the new compensation techniques introduced in this paper.


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3389 ◽  
Author(s):  
Chivon Choeung ◽  
Meng Leang Kry ◽  
Young Il Lee

This paper presents a robust control technique for three-phase chargers under unbalanced grid conditions. The control method consists of inner-loop robust grid-current control and outer-loop proportional integral control for constant current (CC) and constant voltage (CV) control. A dual-current control for the inner-loop positive and negative sequence is employed to eliminate the unbalanced current caused by the grid so that a constant current and voltage can be provided to the batteries. The inner-loop robust controllers utilize state feedback with integral action in the dq-synchronous frame. A linear matrix inequality-based optimization scheme is used to determine stabilizing gains of the controllers to maximize the convergence rate to steady state in the presence of uncertainties. The uncertainties of the system are described as the potential variation range of the inductance and resistance in the L-filter.


Sign in / Sign up

Export Citation Format

Share Document